25 research outputs found

    Pretreatment glycemic control status is an independent prognostic factor for cervical cancer patients receiving neoadjuvant chemotherapy for locally advanced disease

    No full text
    Abstract Background To investigate whether poor glycemic control status has a negative impact on survival outcomes and tumor response to chemotherapy in patients receiving neoadjuvant chemotherapy (NACT) for locally advanced cervical cancer (LACC). Methods A retrospective cohort study was conducted to examine LACC patients undergoing NACT and radical hysterectomy between 2002 and 2011. Patients were divided into three groups: patients without diabetes mellitus (DM), diabetic patients with good glycemic control, and diabetic patients with poor glycemic control. Hemoglobin A1c (HbA1c) levels were used to indicate glycemic control status. Recurrence-free survival (RFS), cancer-specific survival (CSS) and overall survival (OS) were analyzed using log-rank tests and Cox proportional hazards models. Results In total, 388 patients were included and had a median follow-up time of 39 months (range: 4–67 months). Diabetes mellitus (DM) was diagnosed in 89 (22.9%) patients, only 35 (39.3%) of whom had good glycemic control prior to NACT (HbA1c < 7.0%). In survival analysis, compared with patients with good glycemic control and patients without DM, patients with poor glycemic control (HbA1c ≥ 7.0%) exhibited decreased recurrence-free survival (RFS), cancer-specific survival (CSS) and overall survival (OS). In multivariate analysis, HbA1c ≥ 7.0% was identified as an independent predictor for decreased RFS (hazard ratio [HR] = 3.33, P < 0.0001), CSS (HR = 3.60, P < 0.0001) and OS (HR = 4.35, P < 0.0001). In the subgroup of diabetic patients, HbA1c ≥ 7.0% prior to NACT had an independent negative effect on RFS (HR = 2.18, P = 0.044) and OS (HR = 2.29, P = 0.012). When examined as a continuous variable, the HbA1c level was independently associated with decreased RFS (HR = 1.39, P = 0.002), CSS (HR = 1.28, P = 0.021) and OS (HR = 1.27, P = 0.004). Both good (odds ratio [OR] = 0.06, P < 0.0001) and poor glycemic control (OR = 0.04, P < 0.0001) were independently associated with a decreased likelihood of complete response following NACT. Conclusions Poor glycemic control is an independent predictor of survival and tumor response to chemotherapy for patients receiving NACT for LACC

    Additional file 2: Table S1. of Pretreatment glycemic control status is an independent prognostic factor for cervical cancer patients receiving neoadjuvant chemotherapy for locally advanced disease

    No full text
    Univariate and multivariate Cox analysis of prognostic factors associated with survival for diabetic patients with locally advanced cervical cancer who underwent neoadjuvant chemotherapy and radical hysterectomy. (DOCX 23 kb

    In situ Surface-Enhanced Raman Spectroscopic Investigation of Formaldehyde Oxidation on Au-core@Pt-shell Nanoparticles Coated Platinum Electrode in Different Media

    No full text
    Au-core@Pt-shell nanoparticles were synthesized by chemical reduction method. The samples were characterized by scanning electron microscope( SEM ) and energy dispersive spectroscopy ( EDS ). In situ surface-enhanced Raman spectroscopy( SERS ) was utilized to investigate the electro-oxidation behavior of formaldehyde in different media adsorbed on Au-core@Pt-shell nanoparticles coated platinum electrode. Surface-enhanced Raman scattering spectra with high quality were acquired. The results show that formaldehyde can dissociate spontaneously to produce strongly adsorbed intermediate, CO, in acidic, neutral, and alkaline media on a Au-core@Pt-shell nanoparticles coated platinum electrode. However, the bridge adsorbed CO were increased more significantly in alkaline media. In addition, the bridge adsorbed CO could be oxidized more easily than the linear adsorbed CO. The Raman signal of CO disappeared at -0. 4 V in alkaline media, it shifted negatively about 950 mV than in acidic or neutral media. The study demonstrates that Au-core@Pt-shell nanoparticles coated on platinum substrate as electrode exhibited better electrocatalytic properties for the oxidation of formaldehyde in alkaline media than in acidic or neutral media

    CEPC Technical Design Report -- Accelerator

    No full text
    International audienceThe Circular Electron Positron Collider (CEPC) is a large scientific project initiated and hosted by China, fostered through extensive collaboration with international partners. The complex comprises four accelerators: a 30 GeV Linac, a 1.1 GeV Damping Ring, a Booster capable of achieving energies up to 180 GeV, and a Collider operating at varying energy modes (Z, W, H, and ttbar). The Linac and Damping Ring are situated on the surface, while the Booster and Collider are housed in a 100 km circumference underground tunnel, strategically accommodating future expansion with provisions for a Super Proton Proton Collider (SPPC). The CEPC primarily serves as a Higgs factory. In its baseline design with synchrotron radiation (SR) power of 30 MW per beam, it can achieve a luminosity of 5e34 /cm^2/s^1, resulting in an integrated luminosity of 13 /ab for two interaction points over a decade, producing 2.6 million Higgs bosons. Increasing the SR power to 50 MW per beam expands the CEPC's capability to generate 4.3 million Higgs bosons, facilitating precise measurements of Higgs coupling at sub-percent levels, exceeding the precision expected from the HL-LHC by an order of magnitude. This Technical Design Report (TDR) follows the Preliminary Conceptual Design Report (Pre-CDR, 2015) and the Conceptual Design Report (CDR, 2018), comprehensively detailing the machine's layout and performance, physical design and analysis, technical systems design, R&D and prototyping efforts, and associated civil engineering aspects. Additionally, it includes a cost estimate and a preliminary construction timeline, establishing a framework for forthcoming engineering design phase and site selection procedures. Construction is anticipated to begin around 2027-2028, pending government approval, with an estimated duration of 8 years. The commencement of experiments could potentially initiate in the mid-2030s

    CEPC Technical Design Report -- Accelerator

    No full text
    International audienceThe Circular Electron Positron Collider (CEPC) is a large scientific project initiated and hosted by China, fostered through extensive collaboration with international partners. The complex comprises four accelerators: a 30 GeV Linac, a 1.1 GeV Damping Ring, a Booster capable of achieving energies up to 180 GeV, and a Collider operating at varying energy modes (Z, W, H, and ttbar). The Linac and Damping Ring are situated on the surface, while the Booster and Collider are housed in a 100 km circumference underground tunnel, strategically accommodating future expansion with provisions for a Super Proton Proton Collider (SPPC). The CEPC primarily serves as a Higgs factory. In its baseline design with synchrotron radiation (SR) power of 30 MW per beam, it can achieve a luminosity of 5e34 /cm^2/s^1, resulting in an integrated luminosity of 13 /ab for two interaction points over a decade, producing 2.6 million Higgs bosons. Increasing the SR power to 50 MW per beam expands the CEPC's capability to generate 4.3 million Higgs bosons, facilitating precise measurements of Higgs coupling at sub-percent levels, exceeding the precision expected from the HL-LHC by an order of magnitude. This Technical Design Report (TDR) follows the Preliminary Conceptual Design Report (Pre-CDR, 2015) and the Conceptual Design Report (CDR, 2018), comprehensively detailing the machine's layout and performance, physical design and analysis, technical systems design, R&D and prototyping efforts, and associated civil engineering aspects. Additionally, it includes a cost estimate and a preliminary construction timeline, establishing a framework for forthcoming engineering design phase and site selection procedures. Construction is anticipated to begin around 2027-2028, pending government approval, with an estimated duration of 8 years. The commencement of experiments could potentially initiate in the mid-2030s

    CEPC Technical Design Report -- Accelerator

    No full text
    The Circular Electron Positron Collider (CEPC) is a large scientific project initiated and hosted by China, fostered through extensive collaboration with international partners. The complex comprises four accelerators: a 30 GeV Linac, a 1.1 GeV Damping Ring, a Booster capable of achieving energies up to 180 GeV, and a Collider operating at varying energy modes (Z, W, H, and ttbar). The Linac and Damping Ring are situated on the surface, while the Booster and Collider are housed in a 100 km circumference underground tunnel, strategically accommodating future expansion with provisions for a Super Proton Proton Collider (SPPC). The CEPC primarily serves as a Higgs factory. In its baseline design with synchrotron radiation (SR) power of 30 MW per beam, it can achieve a luminosity of 5e34 /cm^2/s^1, resulting in an integrated luminosity of 13 /ab for two interaction points over a decade, producing 2.6 million Higgs bosons. Increasing the SR power to 50 MW per beam expands the CEPC's capability to generate 4.3 million Higgs bosons, facilitating precise measurements of Higgs coupling at sub-percent levels, exceeding the precision expected from the HL-LHC by an order of magnitude. This Technical Design Report (TDR) follows the Preliminary Conceptual Design Report (Pre-CDR, 2015) and the Conceptual Design Report (CDR, 2018), comprehensively detailing the machine's layout and performance, physical design and analysis, technical systems design, R&D and prototyping efforts, and associated civil engineering aspects. Additionally, it includes a cost estimate and a preliminary construction timeline, establishing a framework for forthcoming engineering design phase and site selection procedures. Construction is anticipated to begin around 2027-2028, pending government approval, with an estimated duration of 8 years. The commencement of experiments could potentially initiate in the mid-2030s

    CEPC Technical Design Report -- Accelerator

    No full text
    International audienceThe Circular Electron Positron Collider (CEPC) is a large scientific project initiated and hosted by China, fostered through extensive collaboration with international partners. The complex comprises four accelerators: a 30 GeV Linac, a 1.1 GeV Damping Ring, a Booster capable of achieving energies up to 180 GeV, and a Collider operating at varying energy modes (Z, W, H, and ttbar). The Linac and Damping Ring are situated on the surface, while the Booster and Collider are housed in a 100 km circumference underground tunnel, strategically accommodating future expansion with provisions for a Super Proton Proton Collider (SPPC). The CEPC primarily serves as a Higgs factory. In its baseline design with synchrotron radiation (SR) power of 30 MW per beam, it can achieve a luminosity of 5e34 /cm^2/s^1, resulting in an integrated luminosity of 13 /ab for two interaction points over a decade, producing 2.6 million Higgs bosons. Increasing the SR power to 50 MW per beam expands the CEPC's capability to generate 4.3 million Higgs bosons, facilitating precise measurements of Higgs coupling at sub-percent levels, exceeding the precision expected from the HL-LHC by an order of magnitude. This Technical Design Report (TDR) follows the Preliminary Conceptual Design Report (Pre-CDR, 2015) and the Conceptual Design Report (CDR, 2018), comprehensively detailing the machine's layout and performance, physical design and analysis, technical systems design, R&D and prototyping efforts, and associated civil engineering aspects. Additionally, it includes a cost estimate and a preliminary construction timeline, establishing a framework for forthcoming engineering design phase and site selection procedures. Construction is anticipated to begin around 2027-2028, pending government approval, with an estimated duration of 8 years. The commencement of experiments could potentially initiate in the mid-2030s
    corecore