198 research outputs found
Heat flux identification using reduced model and the adjoint method. Application to a brake disk rotating at variable velocity
International audienceIn previous works [1], reduced models have been used for solving inverse problems, characterized by a complex geometry requiring a large number of nodes and / or an objective of online identification. The treated application was a brake disc in two-dimensional representation, in rotation at variable speed. The dissipated heat flux at the pad-disk interface had been identified by Beck's method. We present here a similar application using the adjoint method. The modal reduction is done by using special bases (called branch bases) that offer the advantage of dealing with nonlinear problems and / or unsteady parameters. Adjoint method provides particularly accurate results in this configuration
G Electronics and Data Acquisition (Forward-Angle Measurements)
The G parity-violation experiment at Jefferson Lab (Newport News, VA) is
designed to determine the contribution of strange/anti-strange quark pairs to
the intrinsic properties of the proton. In the forward-angle part of the
experiment, the asymmetry in the cross section was measured for
elastic scattering by counting the recoil protons corresponding to the two
beam-helicity states. Due to the high accuracy required on the asymmetry, the
G experiment was based on a custom experimental setup with its own
associated electronics and data acquisition (DAQ) system. Highly specialized
time-encoding electronics provided time-of-flight spectra for each detector for
each helicity state. More conventional electronics was used for monitoring
(mainly FastBus). The time-encoding electronics and the DAQ system have been
designed to handle events at a mean rate of 2 MHz per detector with low
deadtime and to minimize helicity-correlated systematic errors. In this paper,
we outline the general architecture and the main features of the electronics
and the DAQ system dedicated to G forward-angle measurements.Comment: 35 pages. 17 figures. This article is to be submitted to NIM section
A. It has been written with Latex using \documentclass{elsart}. Nuclear
Instruments and Methods in Physics Research Section A: Accelerators,
Spectrometers, Detectors and Associated Equipment In Press (2007
Constraining interactions mediated by axion-like particles with ultracold neutrons
We report a new limit on a possible short range spin-dependent interaction
from the precise measurement of the ratio of Larmor precession frequencies of
stored ultracold neutrons and Hg atoms confined in the same volume. The
measurement was performed in a 1 T vertical magnetic holding field
with the apparatus searching for a permanent electric dipole moment of the
neutron at the Paul Scherrer Institute. A possible coupling between freely
precessing polarized neutron spins and unpolarized nucleons of the wall
material can be investigated by searching for a tiny change of the precession
frequencies of neutron and mercury spins. Such a frequency change can be
interpreted as a consequence of a short range spin-dependent interaction that
could possibly be mediated by axions or axion-like particles. The interaction
strength is proportional to the CP violating product of scalar and pseudoscalar
coupling constants . Our result confirms limits from complementary
experiments with spin-polarized nuclei in a model-independent way. Limits from
other neutron experiments are improved by up to two orders of magnitude in the
interaction range of m
An Improved Neutron Electric Dipole Moment Experiment
A new measurement of the neutron EDM, using Ramsey's method of separated
oscillatory fields, is in preparation at the new high intensity source of
ultra-cold neutrons (UCN) at the Paul Scherrer Institute, Villigen, Switzerland
(PSI). The existence of a non-zero nEDM would violate both parity and time
reversal symmetry and, given the CPT theorem, might lead to a discovery of new
CP violating mechanisms. Already the current upper limit for the nEDM
(|d_n|<2.9E-26 e.cm) constrains some extensions of the Standard Model.
The new experiment aims at a two orders of magnitude reduction of the
experimental uncertainty, to be achieved mainly by (1) the higher UCN flux
provided by the new PSI source, (2) better magnetic field control with improved
magnetometry and (3) a double chamber configuration with opposite electric
field directions.
The first stage of the experiment will use an upgrade of the RAL/Sussex/ILL
group's apparatus (which has produced the current best result) moved from
Institut Laue-Langevin to PSI. The final accuracy will be achieved in a further
step with a new spectrometer, presently in the design phase.Comment: Flavor Physics & CP Violation Conference, Taipei, 200
Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins
Physics at the Planck scale could be revealed by looking for tiny violations
of fundamental symmetries in low energy experiments. In 2008, a sensitive test
of the isotropy of the Universe using has been performed with stored ultracold
neutrons (UCN), this is the first clock-comparison experiment performed with
free neutrons. During several days we monitored the Larmor frequency of neutron
spins in a weak magnetic field using the Ramsey resonance technique. An
non-zero cosmic axial field, violating rotational symmetry, would induce a
daily variation of the precession frequency. Our null result constitutes one of
the most stringent tests of Lorentz invariance to date.Comment: proceedings of the PNCMI2010 conferenc
Electron shakeoff following the β+ decay of trapped 35Ar+ ions
The electron shakeoff of 35Cl atoms resulting from the β+ decay of 35Ar+ ions has been investigated using a Paul trap coupled to a recoil-ion spectrometer. The charge-state distribution of the recoiling daughter nuclei is compared to theoretical calculations accounting for shakeoff and Auger processes. The calculations are in excellent agreement with the experimental results and enable one to identify the ionization reaction routes leading to the formation of all charge states.D.R. acknowledges support from the Spanish ministry of Economy and Competitiveness under the project FPA2010-14803 and the action AIC10-D000562
Revised experimental upper limit on the electric dipole moment of the neutron
We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons; an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of dn=−0.21±1.82×10−26 e cm, which may be interpreted as a slightly revised upper limit on the magnitude of the EDM of 3.0×10−26 e cm (90% C.L.) or 3.6×10−26 e cm (95% C.L.)
Probing the high momentum component of the deuteron at high Q^2
The d(e,e'p) cross section at a momentum transfer of 3.5 (GeV/c)^2 was
measured over a kinematical range that made it possible to study this reaction
for a set of fixed missing momenta as a function of the neutron recoil angle
theta_nq and to extract missing momentum distributions for fixed values of
theta_nq up to 0.55 GeV/c. In the region of 35 (deg) <= theta_nq <= 45 (deg)
recent calculations, which predict that final state interactions are small,
agree reasonably well with the experimental data. Therefore these experimental
reduced cross sections provide direct access to the high momentum component of
the deuteron momentum distribution in exclusive deuteron
electro-disintegration.Comment: 5 pages, 2 figure
Gravitational depolarization of ultracold neutrons: comparison with data
We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin-depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data
- …