545 research outputs found

    Group-IV graphene- and graphane-like nanosheets

    Full text link
    We performed a first principles investigation on the structural and electronic properties of group-IV (C, SiC, Si, Ge, and Sn) graphene-like sheets in flat and buckled configurations and the respective hydrogenated or fluorinated graphane-like ones. The analysis on the energetics, associated with the formation of those structures, showed that fluorinated graphane-like sheets are very stable, and should be easily synthesized in laboratory. We also studied the changes on the properties of the graphene-like sheets, as result of hydrogenation or fluorination. The interatomic distances in those graphane-like sheets are consistent with the respective crystalline ones, a property that may facilitate integration of those sheets within three-dimensional nanodevices

    A new view of electrochemistry at highly oriented pyrolytic graphite

    Get PDF
    Major new insights on electrochemical processes at graphite electrodes are reported, following extensive investigations of two of the most studied redox couples, Fe(CN)64–/3– and Ru(NH3)63+/2+. Experiments have been carried out on five different grades of highly oriented pyrolytic graphite (HOPG) that vary in step-edge height and surface coverage. Significantly, the same electrochemical characteristic is observed on all surfaces, independent of surface quality: initial cyclic voltammetry (CV) is close to reversible on freshly cleaved surfaces (>400 measurements for Fe(CN)64–/3– and >100 for Ru(NH3)63+/2+), in marked contrast to previous studies that have found very slow electron transfer (ET) kinetics, with an interpretation that ET only occurs at step edges. Significantly, high spatial resolution electrochemical imaging with scanning electrochemical cell microscopy, on the highest quality mechanically cleaved HOPG, demonstrates definitively that the pristine basal surface supports fast ET, and that ET is not confined to step edges. However, the history of the HOPG surface strongly influences the electrochemical behavior. Thus, Fe(CN)64–/3– shows markedly diminished ET kinetics with either extended exposure of the HOPG surface to the ambient environment or repeated CV measurements. In situ atomic force microscopy (AFM) reveals that the deterioration in apparent ET kinetics is coupled with the deposition of material on the HOPG electrode, while conducting-AFM highlights that, after cleaving, the local surface conductivity of HOPG deteriorates significantly with time. These observations and new insights are not only important for graphite, but have significant implications for electrochemistry at related carbon materials such as graphene and carbon nanotubes

    Evidence of silicene in honeycomb structures of silicon on Ag(111)

    Full text link
    In the search for evidence of silicene, a two-dimensional honeycomb lattice of silicon, it is important to obtain a complete picture for the evolution of Si structures on Ag(111), which is believed to be the most suitable substrate for growth of silicene so far. In this work we report the finding and evolution of several monolayer superstructures of silicon on Ag(111) depending on the coverage and temperature. Combined with first-principles calculations, the detailed structures of these phases have been illuminated. These structure were found to share common building blocks of silicon rings, and they evolve from a fragment of silicene to a complete monolayer silicene and multilayer silicene. Our results elucidate how silicene formes on Ag(111) surface and provide methods to synthesize high-quality and large-scale silicene.Comment: 6 pages, 4 figure

    Label-free Detection of Influenza Viruses using a Reduced Graphene Oxide-based Electrochemical Immunosensor Integrated with a Microfluidic Platform

    Get PDF
    Reduced graphene oxide (RGO) has recently gained considerable attention for use in electrochemical biosensing applications due to its outstanding conducting properties and large surface area. This report presents a novel microfluidic chip integrated with an RGO-based electrochemical immunosensor for label-free detection of an influenza virus, H1N1. Three microelectrodes were fabricated on a glass substrate using the photolithographic technique, and the working electrode was functionalized using RGO and monoclonal antibodies specific to the virus. These chips were integrated with polydimethylsiloxane microchannels. Structural and morphological characterizations were performed using X-ray photoelectron spectroscopy and scanning electron microscopy. Electrochemical studies revealed good selectivity and an enhanced detection limit of 0.5 PFU mL(-1), where the chronoamperometric current increased linearly with H1N1 virus concentration within the range of 1 to 104 PFU mL(-1) (R-2 = 0.99). This microfluidic immunosensor can provide a promising platform for effective detection of biomolecules using minute samples.ope

    Electrochemical oxidation of dihydronicotinamide adenine dinucleotide (NADH) : Comparison of highly oriented pyrolytic graphite (HOPG) and polycrystalline boron-doped diamond (pBDD) electrodes

    Get PDF
    The electro-oxidation of nicotinamide adenine dinucleotide (NADH) is studied at bare surfaces of highly oriented pyrolytic graphite (HOPG) and semi-metallic polycrystalline boron-doped diamond (pBDD). A comparison of these two carbon electrode materials is interesting because they possess broadly similar densities of electronic states that are much lower than most metal electrodes, but graphite has carbon sp2-hybridization, while in diamond the carbon is sp3-hybridised, with resulting major differences in bulk structure and surface termination. Using cyclic voltammetry (CV), it is shown that NADH oxidation is facile at HOPG surfaces but the reaction products tend to strongly adsorb, which causes rapid deactivation of the electrode activity. This is an important factor that needs to be taken into account when assessing HOPG and its intrinsic activity. It is also shown that NADH itself adsorbs at HOPG, a fact that has not been recognized previously, but has implications for understanding the mechanism of the electro-oxidation process. Although pBDD was found to be less susceptible to surface fouling, pBDD is not immune to deterioration of the electrode response, and the reaction showed more sluggish kinetics on this electrode. Scanning electrochemical cell microscopy (SECCM) highlights a significant voltammetric variation in electroactivity between different crystal surface facets that are presented to solution with a pBDD electrode. The electroactivity of different grains correlates with the local dopant level, as visualized by field emission-scanning electron microscopy. SECCM measurements further prove that the basal plane of HOPG has high activity towards NADH electro-oxidation. These new insights on NADH voltammetry are useful for the design of optimal carbon-based electrodes for NADH electroanalysis

    Biocompatibility of poly(lactic acid) with incorporated graphene-based materials

    Get PDF
    The incorporation of graphene-based materials has been shown to improve mechanical properties of poly(lactic acid) (PLA). In this work, PLA films and composite PLA films incorporating two graphene-based materials – graphene oxide (GO) and graphene nanoplatelets (GNP) – were prepared and characterized regarding not only biocompatibility, but also surface topography, chemistry and wettability. The presence of both fillers changed the films surface topography, increasing the roughness, and modified the wettability – the polar component of surface free energy increased 59% with GO and decreased 56% with GNP. Mouse embryo fibroblasts incubated with both fillers exceeded the IC50 in both cases with a concentration of 10 μg mL−1. No variations in cell proliferation at the surface of the composite films were observed, except for those containing GO after 24 h incubation, which presented higher cell proliferation than pristine PLA films. Platelet adhesion to PLA and PLA/GNP films was lower in the presence of plasma proteins than when no proteins were present. Furthermore, incorporation of GNP into PLA reduced platelet activation in the presence of plasma proteins. The results indicated that low concentrations of GO and GNP may be incorporated safely in PLA to improve aspects relevant for biomedical applications, such as mechanical properties.Funding for this work was partially provided by FEDER, through Programa Operacional Factores de Competitividade - COMPETE, and by National Funding through FCT - Fundacao para a Ciencia e a Tecnologia, in the framework of project PTDC/EME-PME/114808/2009 and of grant SFRH/BPD/63722/2009

    Scalable production of large quantities of defect-free few-layer graphene by shear exfoliation in liquids

    Get PDF
    To progress from the laboratory to commercial applications, it will be necessary to develop industrially scalable methods to produce large quantities of defect-free graphene. Here we show that high-shear mixing of graphite in suitable stabilizing liquids results in large-scale exfoliation to give dispersions of graphene nanosheets. X-ray photoelectron spectroscopy and Raman spectroscopy show the exfoliated flakes to be unoxidized and free of basal-plane defects. We have developed a simple model that shows exfoliation to occur once the local shear rate exceeds 10(4) s(-1). By fully characterizing the scaling behaviour of the graphene production rate, we show that exfoliation can be achieved in liquid volumes from hundreds of millilitres up to hundreds of litres and beyond. The graphene produced by this method performs well in applications from composites to conductive coatings. This method can be applied to exfoliate BN, MoS2 and a range of other layered crystals
    corecore