67 research outputs found

    Network evolution and the spatiotemporal dynamics of knowledge sourcing

    Get PDF
    Knowledge accessing from external organisations is important to firms, especially entrepreneurial ones which often cannot generate internally all the knowledge necessary for innovation. There is, however, a lack of evidence concerning the association between the evolution of firms and the evolution of their networks. The aim of this paper is to begin to fill this gap by undertaking an exploratory analysis of the relationship between the vintage of firms and their knowledge sourcing networks. Drawing on an analysis of firms in the UK, the paper finds some evidence of a U-shaped relationship existing between firm age and the frequency of accessing knowledge from certain sources. Emerging entrepreneurial firms tend to be highly active with regard to accessing knowledge for a range of sources and geographic locations, with the rate of networking dropping somewhat during the period of peak firm growth. For instance, it is found that firms tend to less frequently access knowledge sources such as universities and research institutes in their own region during a stage of peak turnover growth. Overall, the results suggest a complex relationship between the lifecycle of the firm and its networking patterns. It is concluded that policymakers need to become more aware that network formation and utilisation by firms is likely to vary dependent upon their lifecycle position

    X-ray diffraction from bone employing annular and semi-annular beams

    Get PDF
    This is the final version of the article. Available from the publisher via the DOI in this record.There is a compelling need for accurate, low cost diagnostics to identify osteo-tissues that are associated with a high risk of fracture within an individual. To satisfy this requirement the quantification of bone characteristics such as 'bone quality' need to exceed that provided currently by densitometry. Bone mineral chemistry and microstructure can be determined from coherent x-ray scatter signatures of bone specimens. Therefore, if these signatures can be measured, in vivo, to an appropriate accuracy it should be possible by extending terms within a fracture risk model to improve fracture risk prediction.In this preliminary study we present an examination of a new x-ray diffraction technique that employs hollow annular and semi-annular beams to measure aspects of 'bone quality'. We present diffractograms obtained with our approach from ex vivo bone specimens at Mo Kα and W Kα energies. Primary data is parameterized to provide estimates of bone characteristics and to indicate the precision with which these can be determined.We acknowledge gratefully the funding provided by the UK Engineering and Physical Sciences Research Council (EPSRC) grant number EP/K020196/

    Modeling the dynamics of cerebrovascular reactivity to carbon dioxide in fMRI under task and resting-state conditions

    Get PDF
    Conventionally, cerebrovascular reactivity (CVR) is estimated as the amplitude of the hemodynamic response to vascular stimuli, most commonly carbon dioxide (CO(2)). While the CVR amplitude has established clinical utility, the temporal characteristics of CVR (dCVR) have been increasingly explored and may yield even more pathology-sensitive parameters. This work is motivated by the current need to evaluate the feasibility of dCVR modeling in various experimental conditions. In this work, we present a comparison of several recently published/utilized model-based deconvolution (response estimation) approaches for estimating the CO(2) response function h(t), including maximum a posteriori likelihood (MAP), inverse logit (IL), canonical correlation analysis (CCA), and basis expansion (using Gamma and Laguerre basis sets). To aid the comparison, we devised a novel simulation framework that incorporates a wide range of SNRs, ranging from 10 to -7 dB, representative of both task and resting-state CO(2) changes. In addition, we built ground-truth h(t) into our simulation framework, overcoming the conventional limitation that the true h(t) is unknown. Moreover, to best represent realistic noise found in fMRI scans, we extracted noise from in-vivo resting-state scans. Furthermore, we introduce a simple optimization of the CCA method (CCA(opt)) and compare its performance to these existing methods. Our findings suggest that model-based methods can accurately estimate dCVR even amidst high noise (i.e. resting-state), and in a manner that is largely independent of the underlying model assumptions for each method. We also provide a quantitative basis for making methodological choices, based on the desired dCVR parameters, the estimation accuracy and computation time. The BEL method provided the highest accuracy and robustness, followed by the CCA(opt) and IL methods. Of the three, the CCA(opt) method has the lowest computational requirements. These findings lay the foundation for wider adoption of dCVR estimation in CVR mapping

    Simulations and experimental demonstrations of encoding for X-ray coherent scattering

    Get PDF
    Diffraction data may be measured using approaches that lead to ambiguity in the interpretation of scattering distributions. Thus, the encoding and decoding of coherent scattering distributions have been considered with a view to enabling unequivocal data interpretation. Two encoding regimes are considered, where encoding occurs between the X-ray source and sample, and where the encoder is placed between the sample and detector. In the first case, the successful recovery of diffraction data formed from the interrogation of powder samples with annular incident beams is presented using a coded aperture approach. In the second regime, encoding of Debye cones is shown to enable recovery of the sample position relative to the detector. The errors associated with both regimes are considered and the advantages of combining the two discussed

    Depth resolved snapshot energy-dispersive X-ray diffraction using a conical shell beam

    Get PDF
    We demonstrate a novel imaging architecture to collect range encoded diffraction patterns from overlapping samples in a single conical shell projection. The patterns were measured in the dark area encompassed by the beam via a centrally positioned aperture optically coupled to a pixelated energy-resolving detector. We show that a single exposure measurement of 0.3 mAs enables d-spacing values to be calculated. The axial positions of the samples were not required and the resultant measurements were robust in the presence of crystallographic textures. Our results demonstrate rapid volumetric materials characterization and the potential for a direct imaging method, which is of great relevance to applications in medicine, non-destructive testing and security screening

    Simulations and experimental demonstrations of encoding for X-ray coherent scattering

    Get PDF
    Diffraction data may be measured using approaches that lead to ambiguity in the interpretation of scattering distributions. Thus, the encoding and decoding of coherent scatter distributions have been considered with a view to enabling unequivocal data interpretation. Two encoding regimes are considered where encoding occurs between the X-ray source and sample, and where the encoder is placed between the sample and detector. In the first case, the successful recovery of diffraction data formed from the interrogation of powder samples with annular incident beams is presented using a coded aperture approach. In a second regime, encoding of Debye cones is shown to enable recovery of sample position relative to the detector. The errors associated with both regimes are considered and the advantages of combining both discussed

    The path towards a professional identity: An IPA study of Greek family therapy trainees

    Get PDF
    Objective: Contemporary psychotherapy research has focused mainly on practitioners' training and education. The impact of training on professional development and the application of therapeutic skills have been the primary foci of the empirical literature. The aim of this paper is to present the experiences of seven family therapy trainees regarding their personal paths toward the development of professional identity as they underwent training in systemic psychotherapy. Method: In-depth interviews were conducted and analysed using Interpretative Phenomenological Analysis. Results & Conclusions: Seven themes were identified: The Quest, Developing by Relating, Learnings, Personification of Training, Use of Self, Self-Care and Empowerment, and Reflecting on the Role of the Therapist. The findings are discussed with regard to the development of the 'therapist as a person', gaining acknowledgement and autonomy, and the development of a community of therapeutic practice. © 2013 British Association for Counselling and Psychotherapy

    Developing focal construct technology for in vivo diagnosis of osteoporosis

    Get PDF
    Osteoporosis is a prevalent bone disease around the world, characterised by low bone mineral density and increased fracture risk. Currently, the gold standard for identifying osteoporosis and increased fracture risk is through quantification of bone mineral density (BMD), using dual energy X-ray absorption (DEXA). However, the use of BMD to diagnose osteoporosis is not without limitation and arguably the risk of osteoporotic fracture should be determined collectively by bone mass, architecture and physicochemistry of the mineral composite building blocks. Rather than depending exclusively on the 'mass' of bone, our previous research investigated predicting the risk of fracture using 'bone quality'. The work highlighted that the material properties of OP tissue differ significantly to that of 'normal' bone and for the first time reported the clinical value of new biomarkers (obtained from X-ray scatter signatures) for fracture risk prediction. Thus, in order to improve fracture prediction models, diagnostic tools need to be developed which not only measure bone mineral density, but also bone quality. This pilot study builds on our previous work and aims to develop a new technology, Focal Construct Technology (FCT), which is hoped can measure XRD signatures in vivo. Our previous work was performed entirely with interrogating probes applied in transmission mode. This has some disadvantages that would be overcome were reflection mode employed. This study involves the creation of unique, high impact data with the potential to form the basis of a new generation of medical diagnostic instrumentation. A systematic series of conventional reflection mode ex vivo experiments were performed in which bone specimens were examined through increasing thicknesses of overlaying muscle/fat/skin. Further, we applied FCT to these geometries. This had not previously been attempted and required some initial modelling to ensure correct topologies of the hollow beams. The results from this study suggest it may be possible to obtain the parameters in vivo with the same precision as those obtained within the laboratory when using FCT

    Energy-dispersive X-ray diffraction using an annular beam

    Get PDF
    This is the author accepted manuscript. The final version is available from the publisher via the DOI in this record.We demonstrate material phase identification by measuring polychromatic diffraction spots from samples at least 20 mm in diameter and up to 10 mm thick with an energy resolving point detector. Within our method an annular X-ray beam in the form of a conical shell is incident with its symmetry axis normal to an extended polycrystalline sample. The detector is configured to receive diffracted flux transmitted through the sample and is positioned on the symmetry axis of the annular beam. We present the experiment data from a range of different materials and demonstrate the acquisition of useful data with sub-second collection times of 0.5 s; equating to 0.15 mAs. Our technique should be highly relevant in fields that demand rapid analytical methods such as medicine, security screening and non-destructive testing.We acknowledge gratefully the funding provided by the UK Engineering and Physical Sciences Research Council (EPSRC) grant number EP/K020196/1
    • …
    corecore