1,414 research outputs found

    The bag and size limit review: new regulations and summary of submissions

    Get PDF
    Since the new bag and size limits were introduced in December 1991, there have been many suggestions for refinement and improvement of these regulations. This paper includes the summary of submissions to Fisheries Management Paper No 52 - Review of Bag and Size Limit Proposals for Western Australian Recreational Fishers and details new regulations which will come into force on 1 July 1995

    Assessment of Durable SiC JFET Technology for +600 C to -125 C Integrated Circuit Operation

    Get PDF
    Electrical characteristics and circuit design considerations for prototype 6H-SiC JFET integrated circuits (ICs) operating over the broad temperature range of -125 C to +600 C are described. Strategic implementation of circuits with transistors and resistors in the same 6H-SiC n-channel layer enabled ICs with nearly temperature-independent functionality to be achieved. The frequency performance of the circuits declined at temperatures increasingly below or above room temperature, roughly corresponding to the change in 6H-SiC n-channel resistance arising from incomplete carrier ionization at low temperature and decreased electron mobility at high temperature. In addition to very broad temperature functionality, these simple digital and analog demonstration integrated circuits successfully operated with little change in functional characteristics over the course of thousands of hours at 500 C before experiencing interconnect-related failures. With appropriate further development, these initial results establish a new technology foundation for realizing durable 500 C ICs for combustion engine sensing and control, deep-well drilling, and other harsh-environment applications

    Patch Plate Materials Compatibility Assessment

    Get PDF
    Lunar dust proved to be a greater problem during the Apollo missions than was originally anticipated. The highly angular, charged dust particles stuck to seals, radiators, and visors; clogged mechanisms; and abraded space suits. As reported by Apollo 12 astronaut Pete Conrad "We must have had more than a hundred hours suited work with the same equipment, and the wear was not as bad on the training suits as it is on these flight suits in just the eight hours we were out.". Dust clinging to surfaces was also transport-ed into habitable spaces leading to lung and eye irritation of the astronauts. The Apollo astronauts were on the Lunar surface less than 24 hours and experienced many dust related problems. With the Artemis program, we are planning longer stays on the surface, with more activities that have the potential to put the astronauts and equipment in contact with greater quantities of Lunar dust. The success of these missions will depend on our understanding of material interactions with Lunar dust and the development of ways to mitigate dust effects in cases where exposure to dust will lead to failure of components, unacceptable loss of power or thermal control, unacceptable loss of visibility, or health issues. Through the Lunar Surface In-novation Initiative (LSII), we are initiating a Patch Plate Materials Compatibility Assessment project. The overall goal of the three year project is to develop passive approaches to mitigate Lunar dust adhesion to surfaces for technologies that are currently at TRL levels 2-3 to bring them to TRL level 5 through ground-based assessment, culminating in a demonstration flight experiment on a Commercial Lunar Payload Services (CLPS) lander in 2022-2023. This paper discusses the detailed technical objectives and approach for this project. References: Gaier, J.R. "The Effects of Lunar Dust on EVA Systems During the Apollo Missions," NASA/TM-2005-213610/REV1, (2005), Apollo 12 Technical Crew Debriefing, December 1, 1969, pp. 10-54

    Relationships power oligarchy to Ukraine and their impact on the Ukrainian policy (information dimension)

    Get PDF
    The aim of this study was to analyze the relationship Ukrainian authorities with oligarchy and show its impact on foreign policy. Author was focusing on the analysis of the oligarchic clans and presented their pat on future foreign policy.М.Прокоп (Maryana Prokop), аспіранткa кафедри Східної Європи Університету Миколи Коперника в Торуні (Uniwersytet Mikołaja Kopernika w Toruniu) Й.П'єхов'як-Лампарська (Joanna Piechowiak-Lamparska), аспіранткa кафедри Східної Європи Університету Миколи Коперника в Торуні (Uniwersytet Mikołaja Kopernika w Toruniu) (Польща , м. Торунь) Науковий керівник: проф., докт. габ. Інституту політології Департаменту соціальних наук Вармінсько-Мазурського університету О.Васюті (О. Wasyuti) (Польща, м. Ольштин

    Towards automatic pulmonary nodule management in lung cancer screening with deep learning

    Get PDF
    The introduction of lung cancer screening programs will produce an unprecedented amount of chest CT scans in the near future, which radiologists will have to read in order to decide on a patient follow-up strategy. According to the current guidelines, the workup of screen-detected nodules strongly relies on nodule size and nodule type. In this paper, we present a deep learning system based on multi-stream multi-scale convolutional networks, which automatically classifies all nodule types relevant for nodule workup. The system processes raw CT data containing a nodule without the need for any additional information such as nodule segmentation or nodule size and learns a representation of 3D data by analyzing an arbitrary number of 2D views of a given nodule. The deep learning system was trained with data from the Italian MILD screening trial and validated on an independent set of data from the Danish DLCST screening trial. We analyze the advantage of processing nodules at multiple scales with a multi-stream convolutional network architecture, and we show that the proposed deep learning system achieves performance at classifying nodule type that surpasses the one of classical machine learning approaches and is within the inter-observer variability among four experienced human observers.Comment: Published on Scientific Report

    Study of the island morphology at the early stages of Fe/Mo(110) MBE growth

    Full text link
    We present theoretical study of morphology of Fe islands grown at Mo(110) surface in sub-monolayer MBE mode. We utilize atomistic SOS model with bond counting, and interactions of Fe adatom up to third nearest neighbors. We performed KMC simulations for different values of adatom interactions and varying temperatures. We have found that, while for the low temperature islands are fat fractals, for the temperature 500K islands have faceted rhombic-like shape. For the higher temperature, islands acquire a rounded shape. In order to evaluated qualitatively morphological changes, we measured averaged aspect ration of islands. We calculated dependence of the average aspect ratio on the temperature, and on the strength of interactions of an adatom with neighbors.Comment: 6 pages, 6 figures. Proceedings of 11-th Symposium on Surface Physics, Prague 200

    Smart Power Supply for Battery-Powered Systems

    Get PDF
    A power supply for battery-powered systems has been designed with an embedded controller that is capable of monitoring and maintaining batteries, charging hardware, while maintaining output power. The power supply is primarily designed for rovers and other remote science and engineering vehicles, but it can be used in any battery alone, or battery and charging source applications. The supply can function autonomously, or can be connected to a host processor through a serial communications link. It can be programmed a priori or on the fly to return current and voltage readings to a host. It has two output power busses: a constant 24-V direct current nominal bus, and a programmable bus for output from approximately 24 up to approximately 50 V. The programmable bus voltage level, and its output power limit, can be changed on the fly as well. The power supply also offers options to reduce the programmable bus to 24 V when the set power limit is reached, limiting output power in the case of a system fault detected in the system. The smart power supply is based on an embedded 8051-type single-chip microcontroller. This choice was made in that a credible progression to flight (radiation hard, high reliability) can be assumed as many 8051 processors or gate arrays capable of accepting 8051-type core presently exist and will continue to do so for some time. To solve the problem of centralized control, this innovation moves an embedded microcontroller to the power supply and assigns it the task of overseeing the operation and charging of the power supply assets. This embedded processor is connected to the application central processor via a serial data link such that the central processor can request updates of various parameters within the supply, such as battery current, bus voltage, remaining power in battery estimations, etc. This supply has a direct connection to the battery bus for common (quiescent) power application. Because components from multiple vendors may have differing power needs, this supply also has a secondary power bus, which can be programmed a priori or on-the-fly to boost the primary battery voltage level from 24 to 50 V to accommodate various loads as they are brought on line. Through voltage and current monitoring, the device can also shield the charging source from overloads, keep it within safe operating modes, and can meter available power to the application and maintain safe operations

    Apparatus and Method for Communication over Power Lines

    Get PDF
    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line
    corecore