31 research outputs found

    A Multidimensional Rasch Analysis of the Functional Independence Measure Based on the National Institute on Disability, Independent Living, and Rehabilitation Research Traumatic Brain Injury Model Systems National Database

    Get PDF
    A number of studies have evaluated the psychometric properties of the Functional Independence Measure (FIM™) using Rasch analysis, although none has done so using the National Institute on Disability, Independent Living, and Rehabilitation Research Traumatic Brain Injury Model Systems National Database, a longitudinal database that captures demographic and outcome information on persons with moderate to severe traumatic brain injury across the United States. In the current study, we examine the psychometric properties of the FIM as represented by persons within this database and demonstrate that the FIM comprises three subscales representing cognitive, self-care, and mobility domains. These subscales were analyzed simultaneously using a multivariate Rasch model in combination with a time dependent concurrent calibration scheme with the goal of creating a raw score-to-logit transformation that can be used to improve the accuracy of parametric statistical analyses. The bowel and bladder function items were removed because of misfit with the motor and cognitive items. Some motor items exhibited step disorder, which was addressed by collapsing Categories 1-3 for Toileting, Stairs, Locomotion, Tub/Shower Transfers; Categories 1 and 2 for Toilet and Bed Transfers; and Categories 2 and 3 for Grooming. The strong correlations (r = 0.82-0.96) among the three subscales suggest they should be modeled together. Coefficient alpha of 0.98 indicates high internal consistency. Keyform maps are provided to enhance clinical interpretation and application of study results

    Predictive utility of an adapted Marshall head CT classification scheme after traumatic brain injury

    Get PDF
    Objective: To study the predictive relationship among persons with traumatic brain injury (TBI) between an objective indicator of injury severity (the adapted Marshall computed tomography [CT] classification scheme) and clinical indicators of injury severity in the acute phase, functional outcomes at inpatient rehabilitation discharge, and functional and participation outcomes at 1 year after injury, including death.Participants: The sample involved 4895 individuals who received inpatient rehabilitation following acute hospitalization for TBI and were enrolled in the Traumatic Brain Injury Model Systems National Database between 1989 and 2014.Design: Head CT variables for each person were fit into adapted Marshall CT classification categories I through IV.Main Measures: Prediction models were developed to determine the amount of variability explained by the CT classification categories compared with commonly used predictors, including a clinical indicator of injury severity.Results: The adapted Marshall classification categories aided only in the prediction of craniotomy or craniectomy during acute hospitalization, otherwise making no meaningful contribution to variance in the multivariable models predicting outcomes at any time point after injury.Conclusion: Results suggest that head CT findings classified in this manner do not inform clinical discussions related to functional prognosis or rehabilitation planning after TBI

    The Study of TeV Variability and Duty Cycle of Mrk 421 from 3 Years of Observations with the Milagro Observatory

    Full text link
    TeV flaring activity with time scales as short as tens of minutes and an orphan TeV flare have been observed from the blazar Markarian 421 (Mrk 421). The TeV emission from Mrk 421 is believed to be produced by leptonic synchrotron self-Compton (SSC) emission. In this scenario, correlations between the X-ray and the TeV fluxes are expected, TeV orphan flares are hardly explained and the activity (measured as duty cycle) of the source at TeV energies is expected to be equal or less than that observed in X-rays if only SSC is considered. To estimate the TeV duty cycle of Mrk 421 and to establish limits on its variability at different time scales, we continuously observed Mrk 421 with the Milagro observatory. Mrk 421 was detected by Milagro with a statistical significance of 7.1 standard deviations between 2005 September 21 and 2008 March 15. The observed spectrum is consistent with previous observations by VERITAS. We estimate the duty cycle of Mrk 421 for energies above 1 TeV for different hypothesis of the baseline flux and for different flare selections and we compare our results with the X-ray duty cycle estimated by Resconi et al. 2009. The robustness of the results is discussed.Comment: 27 pages, 6 figures, ApJ accepte

    Spectrum and Morphology of the Two Brightest Milagro Sources in the Cygnus Region: MGRO J2019+37 and MGRO J2031+41

    Get PDF
    The Cygnus region is a very bright and complex portion of the TeV sky, host to unidentified sources and a diffuse excess with respect to conventional cosmic-ray propagation models. Two of the brightest TeV sources, MGRO J2019+37 and MGRO J2031+41, are analyzed using Milagro data with a new technique, and their emission is tested under two different spectral assumptions: a power law and a power law with an exponential cutoff. The new analysis technique is based on an energy estimator that uses the fraction of photomultiplier tubes in the observatory that detect the extensive air shower. The photon spectrum is measured in the range 1 to 200 TeV using the last 3 years of Milagro data (2005-2008), with the detector in its final configuration. MGRO J2019+37 is detected with a significance of 12.3 standard deviations (σ\sigma), and is better fit by a power law with an exponential cutoff than by a simple power law, with a probability >98>98% (F-test). The best-fitting parameters for the power law with exponential cutoff model are a normalization at 10 TeV of 72+5×10107^{+5}_{-2}\times10^{-10} s1m2TeV1\mathrm{s^{-1}\: m^{-2}\: TeV^{-1}}, a spectral index of 2.01.0+0.52.0^{+0.5}_{-1.0} and a cutoff energy of 2916+5029^{+50}_{-16} TeV. MGRO J2031+41 is detected with a significance of 7.3σ\sigma, with no evidence of a cutoff. The best-fitting parameters for a power law are a normalization of 2.40.5+0.6×10102.4^{+0.6}_{-0.5}\times10^{-10} s1m2TeV1\mathrm{s^{-1}\: m^{-2}\: TeV^{-1}} and a spectral index of 3.080.17+0.193.08^{+0.19}_{-0.17}. The overall flux is subject to an \sim30% systematic uncertainty. The systematic uncertainty on the power law indices is \sim0.1. A comparison with previous results from TeV J2032+4130, MGRO J2031+41 and MGRO J2019+37 is also presented.Comment: 11 pages, 10 figure

    Observation and Spectral Measurements of the Crab Nebula with Milagro

    Full text link
    The Crab Nebula was detected with the Milagro experiment at a statistical significance of 17 standard deviations over the lifetime of the experiment. The experiment was sensitive to approximately 100 GeV - 100 TeV gamma ray air showers by observing the particle footprint reaching the ground. The fraction of detectors recording signals from photons at the ground is a suitable proxy for the energy of the primary particle and has been used to measure the photon energy spectrum of the Crab Nebula between ~1 and ~100 TeV. The TeV emission is believed to be caused by inverse-Compton up-scattering scattering of ambient photons by an energetic electron population. The location of a TeV steepening or cutoff in the energy spectrum reveals important details about the underlying electron population. We describe the experiment and the technique for distinguishing gamma-ray events from the much more-abundant hadronic events. We describe the calculation of the significance of the excess from the Crab and how the energy spectrum is fit. The fit is consistent with values measured by IACTs between 1 and 20 TeV. Fixing the spectral index to values that have been measured below 1 TeV by IACT experiments (2.4 to 2.6), the fit to the Milagro data suggests that Crab exhibits a spectral steepening or cutoff between about 20 to 40 TeV.Comment: Submitted to Astrophysical Journa

    Milagro Observations of Potential TeV Emitters

    Get PDF
    This paper reports the results from three targeted searches of Milagro TeV sky maps: two extragalactic point source lists and one pulsar source list. The first extragalactic candidate list consists of 709 candidates selected from the Fermi-LAT 2FGL catalog. The second extragalactic candidate list contains 31 candidates selected from the TeVCat source catalog that have been detected by imaging atmospheric Cherenkov telescopes (IACTs). In both extragalactic candidate lists Mkn 421 was the only source detected by Milagro. This paper presents the Milagro TeV flux for Mkn 421 and flux limits for the brighter Fermi- LAT extragalactic sources and for all TeVCat candidates. The pulsar list extends a previously published Milagro targeted search for Galactic sources. With the 32 new gamma-ray pulsars identified in 2FGL, the number of pulsars that are studied by both Fermi-LAT and Milagro is increased to 52. In this sample, we find that the probability of Milagro detecting a TeV emission coincident with a pulsar increases with the GeV flux observed by the Fermi-LAT in the energy range from 0.1 GeV to 100 GeV

    Milagro Observations of Multi-TeV Emission from Galactic Sources in the Fermi Bright Source List

    Full text link
    We present the result of a search of the Milagro sky map for spatial correlations with sources from a subset of the recent Fermi Bright Source List (BSL). The BSL consists of the 205 most significant sources detected above 100 MeV by the Fermi Large Area Telescope. We select sources based on their categorization in the BSL, taking all confirmed or possible Galactic sources in the field of view of Milagro. Of the 34 Fermi sources selected, 14 are observed by Milagro at a significance of 3 standard deviations or more. We conduct this search with a new analysis which employs newly-optimized gamma-hadron separation and utilizes the full 8-year Milagro dataset. Milagro is sensitive to gamma rays with energy from 1 to 100 TeV with a peak sensitivity from 10-50 TeV depending on the source spectrum and declination. These results extend the observation of these sources far above the Fermi energy band. With the new analysis and additional data, multi-TeV emission is definitively observed associated with the Fermi pulsar, J2229.0+6114, in the Boomerang Pulsar Wind Nebula (PWN). Furthermore, an extended region of multi-TeV emission is associated with the Fermi pulsar, J0634.0+1745, the Geminga pulsar.Comment: Accepted for publication in Astrophysical Journal Letters June 30, 200

    Milagro limits and HAWC sensitivity for the rate-density of evaporating Primordial Black Holes

    Get PDF
    postprin

    The IceCube Data Acquisition System: Signal Capture, Digitization, and Timestamping

    Full text link
    IceCube is a km-scale neutrino observatory under construction at the South Pole with sensors both in the deep ice (InIce) and on the surface (IceTop). The sensors, called Digital Optical Modules (DOMs), detect, digitize and timestamp the signals from optical Cherenkov-radiation photons. The DOM Main Board (MB) data acquisition subsystem is connected to the central DAQ in the IceCube Laboratory (ICL) by a single twisted copper wire-pair and transmits packetized data on demand. Time calibration is maintained throughout the array by regular transmission to the DOMs of precisely timed analog signals, synchronized to a central GPS-disciplined clock. The design goals and consequent features, functional capabilities, and initial performance of the DOM MB, and the operation of a combined array of DOMs as a system, are described here. Experience with the first InIce strings and the IceTop stations indicates that the system design and performance goals have been achieved.Comment: 42 pages, 20 figures, submitted to Nuclear Instruments and Methods
    corecore