79 research outputs found

    Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Get PDF
    Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (P0.05). Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns

    Fracture resistance of zirconia-composite veneered crowns in comparison with zirconia-porcelain crowns.

    Get PDF
    The objectives were to evaluate the fracture resistance and stress concentration in zirconia/composite veneered crowns in comparison to zirconia/porcelain crowns using occlusal fracture resistance and by stress analysis using finite element analysis method. Zirconia substructures were divided into two groups based on the veneering material. A static load was applied occlusally using a ball indenter and the load to fracture was recorded in Newtons (N). The same crown design was used to create 3D crown models and evaluated using FEA. The zirconia/composite crowns subjected to static occlusal load showed comparable results to the zirconia/porcelain crowns. Zirconia/composite crowns showed higher stress on the zirconia substructure at 63.6 and 50.9 MPa on the zirconia substructure veneered with porcelain. In conclusion, zirconia/composite crowns withstood high occlusal loads similar to zirconia/porcelain crowns with no significant difference. However, the zirconia/composite crowns showed higher stress values than the zirconia/porcelain crowns at the zirconia substructure

    Characterisation of machinable structural polymers in restorative dentistry

    Get PDF
    Objectives To characterise the mechanical properties of the machinable polymers Pekkton® (Cendres-Meteaux, Biel/Bienne, Switzerland), Lava Ultimate® (3MESPE, Seefeld, Germany), Vita Enamic® (Ivoclar Vivadent, Schaan, Liechtenstein) and the ceramic IPS e.Max Press® (Ivoclar Vivadent, Schaan, Liechtenstein). To determine the structural integrity of full coverage crowns fabricated from these materials. Methods The following tests were conducted: Biaxial flexural strength (BFS) using the piston on 3 balls jig (n = 10); Vickers Hardness (VH) 10 indentations per sample with 10 kg load & 20 s dwell time (n = 5); Hygroscopic Expansion Change (HEC) in artificial saliva over 68 days (n = 5). Structural Strength (SS) of teeth analogues (n = 20) restored with monolithic crowns from the four materials. Mean values and standard deviations for BFS, VH, HEC and SS tests were calculated and compared using one-way ANOVA with post-hoc Tukey’s test at a level of 5% significance. Results BFS: IPS e.Max Press® (317 MPa ± 37 MPa), Pekkton® (227 MPa ± 18 MPa), Lava Ultimate® (145 MPa ± 18 MPa) and Vita Enamic® (137 MPa ± 7 MPa) with a significance between groups of p < 0.0001. VH: IPS e.Max Press® (5064 MPa ± 131 MPa), Vita Enamic® (1976 MPa ± 12 MPa), Lava Ultimate® (924 MPa ± 27 MPa) and Pekkton® (445MPa ± 21 MPa) with a significance between groups of p < 0.0001. HEC (%vol change): Pekkton® (0.14% ± 0.14%), Vita Enamic® (0.38% ± 0.16%) and Lava Ultimate® (1.06% ± 0.17%). SS for full-coverage crowns: Pekkton® (2037 N ± 49 N no fracture), IPS e.Max Press® (1497 N ± 165 N), Lava Ultimate® (1476 N ± 142 N) and Vita Enamic® (1127 N ± 108 N). Significance The properties investigated suggest that full coverage monolithic PEKK crowns possess adequate mechanical and physical properties for use in the posterior region of the mouth. These results must be considered alongside other data including clinical studies

    Effects of different surface treatments on the shear bond strength of veneering ceramic materials to zirconia

    Get PDF
    PURPOSE: To evaluate and compare the effect of different materials and techniques on the shear bond strength of veneering ceramic materials to zirconia. MATERIALS AND METHODS: 136 sintered zirconia cubes were prepared and randomly divided into four study groups according to corresponding methods of surface treatment and materials: GLN (grinding followed by laser scanning using Noritake Cerabien ZR), SLN (sandblasting followed by laser scanning using Noritake Cerabien ZR), GLV (grinding followed by laser scanning using VITA VM 9), and SLV (sandblasting followed by laser scanning using VITA VM 9). Spraying technique was performed to coat the core. Profilometer, SEM, XRD, EDS, universal testing machine, and stereomicroscope were used to record surface roughness Ra, surface morphology, phase transformation, elemental compositions, shear bond strength SBS values, and failure types, respectively. Specimens were investigated in unaged (not immersed in artificial saliva) and aged (stored in artificial saliva for a month) conditions to evaluate SBS values. RESULTS: Grinding and GLN as first and second surface treatments provided satisfactory Ra values in both conditions (1.05 ± 0.24 µm, 1.30 ± 0.21 µm) compared to sandblasting and other groups (P<.05). The group GLN showed the highest SBS values in both conditions (30.97 ± 3.12 MPa, 29.09 ± 4.17 MPa), while group SLV recorded the lowest (23.96 ± 3.60 MPa, 22.95 ± 3.68 Mpa) (P<.05). Sandblasting showed phase transformation from t-m. Mixed failure type was the commonest among all groups. CONCLUSION: GLN showed to be a reliable method which provided satisfactory bond strength between the veneer ceramic and zirconia. This method might preserve the integrity of fixed dental crowns

    A comparative study of microwave and barrier discharge plasma for the regeneration of spent zeolite catalysts

    Get PDF
    Due to their acid characteristics and pore structure, which can induce high product selectivity; zeolite catalysts are used extensively in industry to catalyse reactions involving hydrocarbons. However, these catalysts can suffer from deactivation due to cracking reactions that result in the deposition of carbon leading to poisoning of the acid sites and blocking of the pores [1]. Depending upon the reaction and the particular catalyst involved this deactivation may take place over several months or even years but in some cases occurs in minutes. Therefore, zeolite catalysts are frequently reactivated / regenerated. This generally involves a thermal treatment involving air which results in oxidation of the carbon [2]. However, the oxidation of carbon is highly exothermic, and if not carefully controlled, results in the generation of exceedingly high localized temperatures which can destroy the zeolite structure and result in subsequent loss of catalyst activity. More conservative thermal treatments can result in incomplete regeneration and again a catalyst displaying inferior activity. This paper explores the use of non-thermal plasma which had been either generated using microwaves or via a barrier discharge to regenerate spent zeolite catalysts. The catalyst, H-mordenite, was tested for the disproportionation of toluene (Figure 1) using conventional heating. The spent catalyst was then regenerated using a plasma or conventional thermal treatment before having its activity re-evaluated for the toluene disproportionation reaction as previous. Fig. 1. Reaction Scheme for Toluene Disproportionation. Interestingly, not only is plasma regeneration highly effective but also catalysts can be regenerated in greatly reduced times. There is an additional advantage in that plasma regeneration can impart physical properties that result in a zeolite that is resistant to further deactivation. However, the results are highly dependent upon the experimental conditions involved for plasma regeneration. References Wu J, Leu L., Appl. Catal., 1983; 7:283-294. M. Guisnet and P. Magnoux, Deactivation of Zeolites by Coking. Prevention of Deactivation and Regeneration. In: Zeolite Microporous Solids: Synthesis, Structure, and Reactivity. E.G. Derouane, F Lemos, C. Naccache, F. Ramôa Ribeiro, Eds. Pages 437-456. Springer 1992

    British Thoracic Society quality standards for home oxygen use in adults.

    Get PDF
    The purpose of the quality standards document is to provide healthcare professionals, commissioners, service providers and patients with a guide to standards of care that should be met for home oxygen provision in the UK, together with measurable markers of good practice. Quality statements are based on the British Thoracic Society (BTS) Guideline for Home Oxygen Use in Adults.This article is freely available via Open Access. Click on the Additional Link above to access the full-text via the publisher's site
    corecore