2,852 research outputs found

    Three‐dimensional turbulence‐resolving simulations of the plunge phenomenon in a tilted channel

    Get PDF
    Hyperpycnal flows are produced when the density of a fluid flowing in a relatively quiescent basin is greater than the density of the fluid in the basin. The density differences can be due to the difference in temperatures, salinity, turbidity, concentration, or a combination of them. When the inflow momentum diminishes, the inflowing fluid eventually plunges under the basin fluid and flows along the bottom floor as an underflow density current. In the present work, 3‐D turbulence‐resolving simulations are performed for an hyperpycnal flow evolving at the bottom floor of a tilted channel. Using advanced numerical techniques designed for supercomputers, the incompressible Navier‐Stokes and transport equations are solved to reproduce numerically the experiments of Lamb et al. (2010, https://doi.org/10.1130/B30125.1) obtained inside a flume with a long tilted ramp. This study focuses on presenting and validating a new numerical framework for the correct reproduction and analysis of the plunge phenomenon and its associated flow features. A very good agreement is found between the experimental data of Lamb et al. (2010), the analytical models of Parker and Toniolo (2007, https://doi.org/10.1061/(ASCE)0733-9429(2007)133:6(690)), and the present turbulence‐resolving simulations. The mixing process between the ambient fluid and the underflow density current is also analyzed thanks to visualizations of vortical structures at the interface

    Energy Consumption Forecasting Using Ensemble Learning Algorithms

    Get PDF
    DCAI 2019: Distributed Computing and Artificial Intelligence, 16th International Conference, Special SessionsThe increase of renewable energy sources of intermittent nature has brought several new challenges for power and energy systems. In order to deal with the variability from the generation side, there is the need to balance it by managing consumption appropriately. Forecasting energy consumption becomes, therefore, more relevant than ever. This paper presents and compares three different ensemble learning methods, namely random forests, gradient boosted regression trees and Adaboost. Hour-ahead electricity load forecasts are presented for the building N of GECAD at ISEP campus. The performance of the forecasting models is assessed, and results show that the Adaboost model is superior to the other considered models for the one-hour ahead forecasts. The results of this study compared to previous works indicates that ensemble learning methods are a viable choice for short-term load forecast.This work has received funding from National Funds through FCT (Fundaçao da Ciencia e Tecnologia) under the project SPET – 29165, call SAICT 2017.info:eu-repo/semantics/publishedVersio

    Low-cost reusable instrumentation for laparoendoscopic single-site nephrectomy: assessment in a porcine model

    Get PDF
    PURPOSE: To test different sets of prebent instruments and a new reusable access device for laparoendoscopic single-site (LESS) surgery. MATERIALS AND METHODS: Three surgeons with previous experience in LESS performed 12 nephrectomies in six pigs. In all procedures, a multichannel access device (X-CONE) and a 5-mm extra-long telescope were used. Four sets of prebent instruments with different profiles (S-portal) were tested: Standard (one straight scissors and one curved grasper), Cuschieri, Carus, and Leroy set (each of them consisting of two curved instruments with different configurations). Assessment was performed based on both objective (procedure time; time to manage the pedicle; time to free kidney) and subjective parameters (entry/exit of instruments; triangulation; dissection up/down; dissection lateral; retraction; interdependence). The subjective assessment tool used was a Likert type scale (1 = easy to 5 = prohibitive). The access device was assessed by using objective (time to complete insertion of device after skin incision) and subjective (significant air leakage, movement constraint) parameters. RESULTS: Time to insertion of the X-CONE was <1 minute in all the cases. Surgeons reported significant insufflant leakage in 58% of cases. The procedure was completed in 10/12 (83%) cases. Mean operative time was 8.3 ± 4.2 minutes, being lower for the Carus group (4.5 min) and higher for the standard group (13 min). Among the different sets, the standard one obtained the best mean scores for all subjective parameters. CONCLUSIONS: X-CONE allows easy abdominal access, and its reusable properties represent cost savings for LESS compared with disposable devices. Prebent instruments might also represent attractive low-cost tools for LESS

    Low-cost reusable instrumentation for laparoendoscopic single-site nephrectomy: assessment in a porcine model

    Get PDF
    PURPOSE: To test different sets of prebent instruments and a new reusable access device for laparoendoscopic single-site (LESS) surgery. MATERIALS AND METHODS: Three surgeons with previous experience in LESS performed 12 nephrectomies in six pigs. In all procedures, a multichannel access device (X-CONE) and a 5-mm extra-long telescope were used. Four sets of prebent instruments with different profiles (S-portal) were tested: Standard (one straight scissors and one curved grasper), Cuschieri, Carus, and Leroy set (each of them consisting of two curved instruments with different configurations). Assessment was performed based on both objective (procedure time; time to manage the pedicle; time to free kidney) and subjective parameters (entry/exit of instruments; triangulation; dissection up/down; dissection lateral; retraction; interdependence). The subjective assessment tool used was a Likert type scale (1 = easy to 5 = prohibitive). The access device was assessed by using objective (time to complete insertion of device after skin incision) and subjective (significant air leakage, movement constraint) parameters. RESULTS: Time to insertion of the X-CONE was <1 minute in all the cases. Surgeons reported significant insufflant leakage in 58% of cases. The procedure was completed in 10/12 (83%) cases. Mean operative time was 8.3 ± 4.2 minutes, being lower for the Carus group (4.5 min) and higher for the standard group (13 min). Among the different sets, the standard one obtained the best mean scores for all subjective parameters. CONCLUSIONS: X-CONE allows easy abdominal access, and its reusable properties represent cost savings for LESS compared with disposable devices. Prebent instruments might also represent attractive low-cost tools for LESS

    Analysing the Impact of Rationality on the Italian Electricity Market

    Get PDF
    International audienceWe analyze the behavior of the Italian electricity market with an agent-based model. In particular, we are interested in testing the assumption that the market participants are fully rational in the economical sense. To this aim, we extend a previous model by considering a wider class of cases. After checking that the new model is a correct generalization of the existing model, we compare three optimization methods to implement the agents rationality and we verify that the model exhibits a very good fit to the real data. This leads us to conclude that our model can be used to predict the behavior of this market

    Prevalence of hepatitis B virus marker positivity and evolution of hepatitis B virus profile, during chemotherapy, in patients with solid tumours

    Get PDF
    To prospectively evaluate the prevalence of hepatitis B virus (HBV) positivity and study the evolution of HBV profile during cancer chemotherapy, serum HBV markers and liver biochemistry were determined in 1008 of 1402 (72%) cancer patients admitted in our Unit and in all 920 (91%) who received chemotherapy. We found that 54 (5.3%) were HBsAg carriers while 443 (44%) had at least one HBV marker positive. Of the latter, 405 (91%) were HBcAb+ve, 321 (72%) HBsAb+ve and 212 (48%) HBeAb+ve. No patient was HBeAg+ve. Among 920 chemotherapy receivers, 374 (41%) were HBcAb+ve, 280 (30%) HBsAb+ve and 178 (19%) HBeAb+ve. Fifty (5.4%) were HBsAg carriers (versus 0.6% in Greek blood donors). All 50 were systematically screened for HBsAg and HBsAb status throughout chemotherapy, during follow-up or until their death, and liver biochemistry was performed before each chemotherapy course. Stable antigenaemia was observed in 43/50 (86%) while 7/50 (14%) developed clinical and/or biochemical hepatitis. Six of these seven developed serum anti-HBs antibodies with an associated decrease of serum HBsAg titres. We conclude that reactivation of HBV infection during chemotherapy is not rare (14%), while disappearance of HBs antigenaemia is neither a frequent nor usually a permanent phenomenon. © 1999 Cancer Research Campaig

    Intra- and interreader reproducibility of PI-RADSv2: A multireader study

    Get PDF
    Background: The Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) has been in use since 2015; while interreader reproducibility has been studied, there has been a paucity of studies investigating the intrareader reproducibility of PI-RADSv2. Purpose: To evaluate both intra- and interreader reproducibility of PI-RADSv2 in the assessment of intraprostatic lesions using multiparametric magnetic resonance imaging (mpMRI). Study Type: Retrospective. Population/Subjects: In all, 102 consecutive biopsy-naïve patients who underwent prostate MRI and subsequent MR/transrectal ultrasonography (MR/TRUS)-guided biopsy. Field Strength/Sequences: Prostate mpMRI at 3T using endorectal with phased array surface coils (TW MRI, DW MRI with ADC maps and b2000 DW MRI, DCE MRI). Assessment: Previously detected and biopsied lesions were scored by four readers from four different institutions using PI-RADSv2. Readers scored lesions during two readout rounds with a 4-week washout period. Statistical Tests: Kappa (κ) statistics and specific agreement (Po) were calculated to quantify intra- and interreader reproducibility of PI-RADSv2 scoring. Lesion measurement agreement was calculated using the intraclass correlation coefficient (ICC). Results: Overall intrareader reproducibility was moderate to substantial (κ = 0.43–0.67, Po = 0.60–0.77), while overall interreader reproducibility was poor to moderate (κ = 0.24, Po = 46). Readers with more experience showed greater interreader reproducibility than readers with intermediate experience in the whole prostate (P = 0.026) and peripheral zone (P = 0.002). Sequence-specific interreader agreement for all readers was similar to the overall PI-RADSv2 score, with κ = 0.24, 0.24, and 0.23 and Po = 0.47, 0.44, and 0.54 in T2-weighted, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE), respectively. Overall intrareader and interreader ICC for lesion measurement was 0.82 and 0.71, respectively. Data Conclusion: PI-RADSv2 provides moderate intrareader reproducibility, poor interreader reproducibility, and moderate interreader lesion measurement reproducibility. These findings suggest a need for more standardized reader training in prostate MRI. Level of Evidence: 2. Technical Efficacy: Stage 2
    corecore