18 research outputs found

    Letter to the Editor Concerning Simultaneous, Single-Particle Measurements of Size and Loading Give Insights into the Structure of Drug-Delivery Nanoparticles

    Full text link
    The vexing error of excess variance in the sizing of single particles degrades accuracy in applications ranging from quality control of nanoparticle products to hazard assessment of nanoplastic byproducts. The particular importance of lipid nanoparticles for vaccine and medicine delivery motivates this comment on a publication1^{\textrm{1}} in ACS Nano. In ref 1, the benchmark measurements of a nanoparticle standard manifest large errors of the size distribution that contradict the claim of validation. Such errors can bias the correlation of fluorescence intensity as an optical proxy for the molecular loading of lipid nanoparticles and give misleading insights from power-law models of intensity−-size data. Looking forward, measurement error models have the potential to address this widespread issue.Comment: Peer reviewed and pending acceptance by ACS Nan

    Subnanometer traceability of localization microscopy

    Full text link
    In localization microscopy, subnanometer precision is possible but supporting accuracy is challenging, and no study has demonstrated reliable traceability to the International System of Units (SI). To do so, we measure the positions of nanoscale apertures in a reference array by traceable atomic-force microscopy, creating a master standard. We perform correlative measurements of this standard by optical microscopy, correcting position errors from optical aberrations by a Zernike calibration. We establish an uncertainty field due to localization errors and scale uncertainty, with regions of position traceability to within a 68 % coverage interval of +/- 1.0 nm. These results enable localization metrology with high throughput, which we apply to measure working standards, validating the subnanometer accuracy of lithographic pitch

    A lateral nanoflow assay reveals nanoplastic fluorescence heterogeneity

    Full text link
    Colloidal nanoplastics present technological opportunities, environmental concerns, and measurement challenges. To meet these challenges, we develop a lateral nanoflow assay from sample-in to answer-out. Our measurement system integrates complex nanofluidic replicas, super-resolution optical microscopy, and comprehensive statistical analyses to measure polystyrene nanoparticles that sorb and carry hydrophobic fluorophores. An elegant scaling of surface forces within our silicone devices hydrodynamically automates the advection and dominates the diffusion of the nanoparticles. Through steric interaction with the replica structure, the particle size distribution reciprocally probes the unknown limits of replica function. Multiple innovations in the integration and calibration of device and microscope improve the accuracy of identifying single nanoparticles and quantifying their diameters and fluorescence intensities. A statistical model of the measurement approaches the information limit of the system, discriminates size exclusion from surface adsorption, and reduces nonideal data to return the particle size distribution with nanometer resolution. A Bayesian statistical analysis of the dimensional and optical properties of single nanoparticles reveals their fundamental structure-property relationship. Fluorescence intensity shows a super-volumetric dependence, scaling with nanoparticle diameter to nearly the fourth power and confounding basic concepts of chemical sorption. Distributions of fluorescivity - the product of the number density, absorption cross section, and quantum yield of an ensemble of fluorophores - are ultrabroad and asymmetric, limiting ensemble analysis and dimensional or chemical inference from fluorescence intensity. These results reset expectations for optimizing nanoplastic products, understanding nanoplastic byproducts, and applying nanoplastic standards

    Endovascular strategy or open repair for ruptured abdominal aortic aneurysm: one-year outcomes from the IMPROVE randomized trial.

    Get PDF
    AIMS: To report the longer term outcomes following either a strategy of endovascular repair first or open repair of ruptured abdominal aortic aneurysm, which are necessary for both patient and clinical decision-making. METHODS AND RESULTS: This pragmatic multicentre (29 UK and 1 Canada) trial randomized 613 patients with a clinical diagnosis of ruptured aneurysm; 316 to an endovascular first strategy (if aortic morphology is suitable, open repair if not) and 297 to open repair. The principal 1-year outcome was mortality; secondary outcomes were re-interventions, hospital discharge, health-related quality-of-life (QoL) (EQ-5D), costs, Quality-Adjusted-Life-Years (QALYs), and cost-effectiveness [incremental net benefit (INB)]. At 1 year, all-cause mortality was 41.1% for the endovascular strategy group and 45.1% for the open repair group, odds ratio 0.85 [95% confidence interval (CI) 0.62, 1.17], P = 0.325, with similar re-intervention rates in each group. The endovascular strategy group and open repair groups had average total hospital stays of 17 and 26 days, respectively, P < 0.001. Patients surviving rupture had higher average EQ-5D utility scores in the endovascular strategy vs. open repair groups, mean differences 0.087 (95% CI 0.017, 0.158), 0.068 (95% CI -0.004, 0.140) at 3 and 12 months, respectively. There were indications that QALYs were higher and costs lower for the endovascular first strategy, combining to give an INB of £3877 (95% CI £253, £7408) or €4356 (95% CI €284, €8323). CONCLUSION: An endovascular first strategy for management of ruptured aneurysms does not offer a survival benefit over 1 year but offers patients faster discharge with better QoL and is cost-effective. CLINICAL TRIAL REGISTRATION: ISRCTN 48334791

    Team dynamics in emergency surgery teams: results from a first international survey

    Get PDF
    Background: Emergency surgery represents a unique context. Trauma teams are often multidisciplinary and need to operate under extreme stress and time constraints, sometimes with no awareness of the trauma\u2019s causes or the patient\u2019s personal and clinical information. In this perspective, the dynamics of how trauma teams function is fundamental to ensuring the best performance and outcomes. Methods: An online survey was conducted among the World Society of Emergency Surgery members in early 2021. 402 fully filled questionnaires on the topics of knowledge translation dynamics and tools, non-technical skills, and difficulties in teamwork were collected. Data were analyzed using the software R, and reported following the Checklist for Reporting Results of Internet E-Surveys (CHERRIES). Results: Findings highlight how several surgeons are still unsure about the meaning and potential of knowledge translation and its mechanisms. Tools like training, clinical guidelines, and non-technical skills are recognized and used in clinical practice. Others, like patients\u2019 and stakeholders\u2019 engagement, are hardly implemented, despite their increasing importance in the modern healthcare scenario. Several difficulties in working as a team are described, including the lack of time, communication, training, trust, and ego. Discussion: Scientific societies should take the lead in offering training and support about the abovementioned topics. Dedicated educational initiatives, practical cases and experiences, workshops and symposia may allow mitigating the difficulties highlighted by the survey\u2019s participants, boosting the performance of emergency teams. Additional investigation of the survey results and its characteristics may lead to more further specific suggestions and potential solutions

    Diversity and ethics in trauma and acute care surgery teams: results from an international survey

    Get PDF
    Background: Investigating the context of trauma and acute care surgery, the article aims at understanding the factors that can enhance some ethical aspects, namely the importance of patient consent, the perceptiveness of the ethical role of the trauma leader, and the perceived importance of ethics as an educational subject. Methods: The article employs an international questionnaire promoted by the World Society of Emergency Surgery. Results: Through the analysis of 402 fully filled questionnaires by surgeons from 72 different countries, the three main ethical topics are investigated through the lens of gender, membership of an academic or non-academic institution, an official trauma team, and a diverse group. In general terms, results highlight greater attention paid by surgeons belonging to academic institutions, official trauma teams, and diverse groups. Conclusions: Our results underline that some organizational factors (e.g., the fact that the team belongs to a university context or is more diverse) might lead to the development of a higher sensibility on ethical matters. Embracing cultural diversity forces trauma teams to deal with different mindsets. Organizations should, therefore, consider those elements in defining their organizational procedures. Level of evidence: Trauma and acute care teams work under tremendous pressure and complex circumstances, with their members needing to make ethical decisions quickly. The international survey allowed to shed light on how team assembly decisions might represent an opportunity to coordinate team member actions and increase performance

    Correction to: Two years later: Is the SARS-CoV-2 pandemic still having an impact on emergency surgery? An international cross-sectional survey among WSES members

    Get PDF
    Background: The SARS-CoV-2 pandemic is still ongoing and a major challenge for health care services worldwide. In the first WSES COVID-19 emergency surgery survey, a strong negative impact on emergency surgery (ES) had been described already early in the pandemic situation. However, the knowledge is limited about current effects of the pandemic on patient flow through emergency rooms, daily routine and decision making in ES as well as their changes over time during the last two pandemic years. This second WSES COVID-19 emergency surgery survey investigates the impact of the SARS-CoV-2 pandemic on ES during the course of the pandemic. Methods: A web survey had been distributed to medical specialists in ES during a four-week period from January 2022, investigating the impact of the pandemic on patients and septic diseases both requiring ES, structural problems due to the pandemic and time-to-intervention in ES routine. Results: 367 collaborators from 59 countries responded to the survey. The majority indicated that the pandemic still significantly impacts on treatment and outcome of surgical emergency patients (83.1% and 78.5%, respectively). As reasons, the collaborators reported decreased case load in ES (44.7%), but patients presenting with more prolonged and severe diseases, especially concerning perforated appendicitis (62.1%) and diverticulitis (57.5%). Otherwise, approximately 50% of the participants still observe a delay in time-to-intervention in ES compared with the situation before the pandemic. Relevant causes leading to enlarged time-to-intervention in ES during the pandemic are persistent problems with in-hospital logistics, lacks in medical staff as well as operating room and intensive care capacities during the pandemic. This leads not only to the need for triage or transferring of ES patients to other hospitals, reported by 64.0% and 48.8% of the collaborators, respectively, but also to paradigm shifts in treatment modalities to non-operative approaches reported by 67.3% of the participants, especially in uncomplicated appendicitis, cholecystitis and multiple-recurrent diverticulitis. Conclusions: The SARS-CoV-2 pandemic still significantly impacts on care and outcome of patients in ES. Well-known problems with in-hospital logistics are not sufficiently resolved by now; however, medical staff shortages and reduced capacities have been dramatically aggravated over last two pandemic years

    The effect of aortic morphology on peri-operative mortality of ruptured abdominal aortic aneurysm

    Get PDF
    Aims To investigate whether aneurysm shape and extent, which indicate whether a patient with ruptured abdominal aortic aneurysm (rAAA) is eligible for endovascular repair (EVAR), influence the outcome of both EVAR and open surgical repair. Methods and results The influence of six morphological parameters (maximum aortic diameter, aneurysm neck diameter, length and conicality, proximal neck angle, and maximum common iliac diameter) on mortality and reinterventions within 30 days was investigated in rAAA patients randomized before morphological assessment in the Immediate Management of the Patient with Rupture: Open Versus Endovascular strategies (IMPROVE) trial. Patients with a proven diagnosis of rAAA, who underwent repair and had their admission computerized tomography scan submitted to the core laboratory, were included. Among 458 patients (364 men, mean age 76 years), who had either EVAR (n = 177) or open repair (n = 281) started, there were 155 deaths and 88 re-interventions within 30 days of randomization analysed according to a pre-specified plan. The mean maximum aortic diameter was 8.6 cm. There were no substantial correlations between the six morphological variables. Aneurysm neck length was shorter in those undergoing open repair (vs. EVAR). Aneurysm neck length (mean 23.3, SD 16.1 mm) was inversely associated with mortality for open repair and overall: adjusted OR 0.72 (95% CI 0.57, 0.92) for each 16 mm (SD) increase in length. There were no convincing associations of morphological parameters with reinterventions. Conclusion Short aneurysm necks adversely influence mortality after open repair of rAAA and preclude conventional EVAR. This may help explain why observational studies, but not randomized trials, have shown an early survival benefit for EVAR. Clinical trial registration: ISRCTN 48334791
    corecore