1,001 research outputs found
Characterisation of the mechanobiology of stents in vitro
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.Long-term efficacy of percutaneous coronary intervention (PCI) to treat coronary heart disease is hampered by incidence of in-stent restenosis (ISR). The regrowth of a healthy endothelial layer post-treatment, a key factor in successful vascular repair, has been shown to be affected by the high sensitivity of endothelial cells (EC) to shear stress. Characterisation of stented artery haemodynamics is required to understand the response of EC to complex flow and shear stress patterns induced by stent structure. A device for the in vitro study of coronary stents has been developed and fabricated in polydimethylsiloxane (PDMS). Balloon-mounted cobalt-chromium stents have been successfully deployed, and particle tracking has been employed to obtain streamlines under low flow rate. High-resolution flow-patterns can be imaged, and complemented with in silico analysis from μCT data. The device allows for the seeding of EC, and sustained exposure to shear stress. EC response can be investigated by comparing real-time footage of cellular migration and proliferation to the haemodynamics of the specific region
In Vitro Bone Cell Models: Impact of Fluid Shear Stress on Bone Formation.
This review describes the role of bone cells and their surrounding matrix in maintaining bone strength through the process of bone remodeling. Subsequently, this work focusses on how bone formation is guided by mechanical forces and fluid shear stress in particular. It has been demonstrated that mechanical stimulation is an important regulator of bone metabolism. Shear stress generated by interstitial fluid flow in the lacunar-canalicular network influences maintenance and healing of bone tissue. Fluid flow is primarily caused by compressive loading of bone as a result of physical activity. Changes in loading, e.g., due to extended periods of bed rest or microgravity in space are associated with altered bone remodeling and formation in vivo. In vitro, it has been reported that bone cells respond to fluid shear stress by releasing osteogenic signaling factors, such as nitric oxide, and prostaglandins. This work focusses on the application of in vitro models to study the effects of fluid flow on bone cell signaling, collagen deposition, and matrix mineralization. Particular attention is given to in vitro set-ups, which allow long-term cell culture and the application of low fluid shear stress. In addition, this review explores what mechanisms influence the orientation of collagen fibers, which determine the anisotropic properties of bone. A better understanding of these mechanisms could facilitate the design of improved tissue-engineered bone implants or more effective bone disease models
Pattern and Decoration: An Ideal Vision in American Art, 1975-1985
This illustrated catalogue accompanied an exhibition at the Hudson River Museum, Yonkers, New York (October 27, 2007-January 20, 2008). It is the first extended discussion of the Pattern and Decoration movement. This exhibition catalogue was edited by Anne Swartz with an introduction by Michael Botwinick, with essays by Temma Balducci, Arthur C. Danto, John Perrault, and Anne Swartz
Mechanism of active targeting in solid tumors with transferrin-containing gold nanoparticles
PEGylated gold nanoparticles are decorated with various amounts of human transferrin (Tf) to give a series of Tf-targeted particles with near-constant size and electrokinetic potential. The effects of Tf content on nanoparticle tumor targeting were investigated in mice bearing s.c. Neuro2A tumors. Quantitative biodistributions of the nanoparticles 24 h after i.v. tail-vein injections show that the nanoparticle accumulations in the tumors and other organs are independent of Tf. However, the nanoparticle localizations within a particular organ are influenced by the Tf content. In tumor tissue, the content of targeting ligands significantly influences the number of nanoparticles localized within the cancer cells. In liver tissue, high Tf content leads to small amounts of the nanoparticles residing in hepatocytes, whereas most nanoparticles remain in nonparenchymal cells. These results suggest that targeted nanoparticles can provide greater intracellular delivery of therapeutic agents to the cancer cells within solid tumors than their nontargeted analogs
Pre-analytical factors affecting whole blood and plasma glucose concentrations in loggerhead sea turtles (Caretta caretta)
Blood glucose is vital for many physiological pathways and can be quantified by clinical chemistry analyzers and in-house point-of-care (POC) devices. Pre-analytical and analytical factors can influence blood glucose measurements. This project aimed to investigate pre-analytical factors on whole blood and plasma glucose measurements in loggerhead sea turtles (Caretta caretta) by evaluating the effects of storage (refrigeration) up to 48h after sampling and of packed cell volume (PCV) on whole blood glucose analysis by POC glucometer (time series n = 13); and by evaluating the effects of storage (room temperature and refrigeration) on plasma glucose concentrations using a dry slide chemistry analyzer (DCA) at various conditions: immediate processing and delayed plasma separation from erythrocytes at 24h and 48h (time series n = 14). The POC glucometer had overall strong agreement with the DCA (CCC = 0.76, r = 0.84, Cb = 0.90), but consistently overestimated glucose concentrations (mean difference: +0.4 mmol/L). The POC glucometer results decreased significantly over time, resulting in a substantial decline within the first 2h (0.41±0.47 mmol/L; 8±9%) that could potentially alter clinical decisions, thereby highlighting the need for immediate analysis using this method. The effects of PCV on glucose could not be assessed, as the statistical significance was associated with one outlier. Storage method significantly affected plasma glucose measurements using DCA, with room temperature samples resulting in rapid decreases of 3.57±0.89 mmol/L (77±9%) over the first 48h, while refrigerated samples provided consistent plasma glucose results over the same time period (decrease of 0.26±0.23 mmol/L; 6±5%). The results from this study provide new insights into optimal blood sample handling and processing for glucose analysis in sea turtles, show the suitability of the POC glucometer as a rapid diagnostic test, and confirm the reliability of plasma glucose measurements using refrigeration. These findings emphasize the need to consider pre-/analytical factors when interpreting blood glucose results from loggerhead sea turtles
Metaphoric coherence: Distinguishing verbal metaphor from `anomaly\u27
Theories and computational models of metaphor comprehension generally circumvent the question of metaphor versus “anomaly” in favor of a treatment of metaphor versus literal language. Making the distinction between metaphoric and “anomalous” expressions is subject to wide variation in judgment, yet humans agree that some potentially metaphoric expressions are much more comprehensible than others. In the context of a program which interprets simple isolated sentences that are potential instances of cross‐modal and other verbal metaphor, I consider some possible coherence criteria which must be satisfied for an expression to be “conceivable” metaphorically. Metaphoric constraints on object nominals are represented as abstracted or extended along with the invariant structural components of the verb meaning in a metaphor. This approach distinguishes what is preserved in metaphoric extension from that which is “violated”, thus referring to both “similarity” and “dissimilarity” views of metaphor. The role and potential limits of represented abstracted properties and constraints is discussed as they relate to the recognition of incoherent semantic combinations and the rejection or adjustment of metaphoric interpretations
A clinically aligned experimental approach for quantitative characterization of patient-specific cardiovascular models
Recent improvements in computational tools opened the possibility of patient-specific modeling to aid clinicians during diagnosis, treatment, and monitoring. One example is the modeling of blood flow for surgical planning, where modeling can help predict the prognosis. Computational analysis is used to extract hemodynamic information about the case; however, these methods are sensitive to assumptions on blood properties, boundary conditions, and appropriate geometry accuracy. When available, experimental measurements can be used to validate the results and, among the modalities, ultrasound-based methods are suitable due to their relative low cost and non-invasiveness. This work proposes a procedure to create accurate patient-specific silicone replicas of blood vessels and a power Doppler compatible experimental setup able to simulate and measure realistic flow conditions. The assessment of silicone model geometry shows small discrepancies between these and the target geometries (median of surface error lies within 57 µm and 82 μm). Power Doppler measurements were compared against computational fluid dynamics results, showing discrepancies within 10% near the wall. The experimental approach offers a setup to quantify flow in in vitro systems and provide more accurate results where other techniques (e.g., particle image velocimetry and particle tracking velocimetry) have shown limitations due to the interference of the interface
The extracellular matrix microtopography drives critical changes in cellular motility and Rho A activity in colon cancer cells
We have shown that the microtopography (mT) underlying colon cancer changes as a tumor de-differentiates. We distinguish the well-differentiated mT based on the increasing number of "pits" and poorly differentiated mT on the basis of increasing number of "posts." We investigated Rho A as a mechanosensing protein using mT features derived from those observed in the ECM of colon cancer. We evaluated Rho A activity in less-tumorogenic (Caco-2 E) and more tumorigenic (SW620) colon cancer cell-lines on microfabricated pits and posts at 2.5 μm diameter and 200 nm depth/height. In Caco-2 E cells, we observed a decrease in Rho A activity as well as in the ratio of G/F actin on surfaces with either pits or posts but despite this low activity, knockdown of Rho A led to a significant decrease in confined motility suggesting that while Rho A activity is reduced on these surfaces it still plays an important role in controlling cellular response to barriers. In SW620 cells, we observed that Rho A activity was greatest in cells plated on a post microtopography which led to increased cell motility, and an increase in actin cytoskeletal turnover
- …