8 research outputs found

    Pacemapping

    Get PDF
    Pacemapping (PM) is an electrophysiologic technique designed to help locating tachycardia sources by stimulating at different endocardial sites in order to reproduce the clinical tachycardia characteristics. A recorded electrocardiogram (ECG) during the clinical tachycardia has been conventionally used as reference. Yet, endocardial activation pattern during tachycardia may be utilized as well to guide the procedure. In focal tachycardia ablation, PM guide has consistently provided remarkable outcomes1, while outcomes in reentrant tachycardia ablation are less favourabl

    Anatomical targets and expected outcomes of catheter-based ablation of atrial fibrillation in 2020.

    Get PDF
    Anatomical-based approaches, targeting either pulmonary vein isolation (PVI) or additional extra PV regions, represent the most commonly used ablation treatments in symptomatic patients with atrial fibrillation (AF) recurrences despite antiarrhythmic drug therapy. PVI remains the main anatomical target during catheter-based AF ablation, with the aid of new technological advances as contact force monitoring to increase safety and effective radiofrequency (RF) lesions. Nowadays, cryoballoon ablation has also achieved the same level of scientific evidence in patients with paroxysmal AF undergoing PVI. In parallel, electrical isolation of extra PV targets has progressively increased, which is associated with a steady increase in complex cases undergoing ablation. Several atrial regions as the left atrial posterior wall, the vein of Marshall, the left atrial appendage, or the coronary sinus have been described in different series as locations potentially involved in AF initiation and maintenance. Targeting these regions may be challenging using conventional point-by-point RF delivery, which has opened new opportunities for coadjuvant alternatives as balloon ablation or selective ethanol injection. Although more extensive ablation may increase intraprocedural AF termination and freedom from arrhythmias during the follow-up, some of the targets to achieve such outcomes are not exempt of potential severe complications. Here, we review and discuss current anatomical approaches and the main ablation technologies to target atrial regions associated with AF initiation and maintenance.This work was supported by the European Regional Development Fund, the Spanish Ministry of Science and Innovation (SAF2016- 80324-R), and the FundaciĂłn Interhospitalaria para la InvestigaciĂłn Cardiovascular (FIC). The Centro Nacional de Investigaciones Cardiovasculares (CNIC) is supported by the Spanish Ministry of Science and Innovation and the Pro-CNIC Foundation, and is a Severo Ochoa Center of Excellence (SEV-2015-0505). Giulio La Rosa has received a fellowship grant from the joint program between the Heart Rhythm Association of the Spanish Society of Cardiology (ARC) and CNIC.S

    Early prognostic value of an Algorithm based on spectral Variables of Ventricular fibrillAtion from the EKG of patients with suddEn cardiac death: A multicentre observational study (AWAKE)

    Get PDF
    Objective: Ventricular fibrillation (VF)-related sudden cardiac death (SCD) is a leading cause of mortality and morbidity. Current biological and imaging parameters show significant limitations on predicting cerebral performance at hospital admission. The AWAKE study (NCT03248557) is a multicentre observational study to validate a model based on spectral ECG analysis to early predict cerebral performance and survival in resuscitated comatose survivors. Methods: Data from VF ECG tracings of patients resuscitated from SCD will be collected using an electronic Case Report Form. Patients can be either comatose (Glasgow Coma Scale – GCS – ≤8) survivors undergoing temperature control after return of spontaneous circulation (RoSC), or those who regain consciousness (GCS = 15) after RoSC; all admitted to Intensive Cardiac Care Units in 4 major university hospitals. VF tracings prior to the first direct current shock will be digitized and analyzed to derive spectral data and feed a predictive model to estimate favorable neurological performance (FNP). The results of the model will be compared to the actual prognosis. Results: The primary clinical outcome is FNP during hospitalization. Patients will be categorized into 4 subsets of neurological prognosis according to the risk score obtained from the predictive model. The secondary clinical outcomes are survival to hospital discharge, and FNP and survival after 6 months of follow-up. The model-derived categorisation will be also compared with clinical variables to assess model sensitivity, specificity, and accuracy. Conclusions: A model based on spectral analysis of VF tracings is a promising tool to obtain early prognostic data after SCD. Resumen: Objetivo: La muerte súbita (MS) por fibrilación ventricular (FV) es una importante causa de morbilidad y mortalidad. Los métodos biológicos y de imagen actuales muestran limitaciones para predecir el pronóstico cerebral al ingreso hospitalario. AWAKE es un estudio observacional, multicéntrico, con el objetivo de validar un modelo basado en el análisis espectral del electrocardiograma (ECG), que predice precozmente el pronóstico cerebral y la supervivencia en pacientes resucitados y en estado de coma. Métodos: Se recogerán datos de los ECG con FV de pacientes reanimados de MS. Los pacientes pueden ser tanto supervivientes en estado de coma (Glasgow Coma Scale [GCS] ≤ 8) sometidos a control de temperatura tras la recuperación de circulación espontánea (RCE), como aquellos que recuperan la consciencia (GCS = 15) tras RCE; todos ellos ingresados en unidades de terapia intensiva cardiológica de 4 hospitales de referencia. Los registros de FV previos al primer choque se digitalizarán y analizarán para obtener datos espectrales que se incluirán en un modelo predictivo que estime el pronóstico neurológico favorable (PNF). El resultado del modelo se comparará con el pronóstico real. Resultados: El objetivo principal es el PNF durante la hospitalización. Los pacientes se categorizarán en 4 subgrupos de pronóstico neurológico según la estimación de riesgo obtenida en el modelo predictivo. Los objetivos secundarios son supervivencia al alta hospitalaria, y PNF y supervivencia a los 6 meses. El resultado de este modelo también se comparará con el pronóstico según variables clínicas. Conclusiones: Un modelo basado en el análisis espectral de registros de FV es una herramienta prometedora para obtener datos pronósticos precoces tras MS por FV. Keywords: Coma, Sudden cardiac death, Ventricular fibrillation, Wavelet analysis, Prognosis, Resuscitation, Spain, Palabras clave: Coma, Muerte súbita, Fibrilación ventricular, Análisis de onda, Pronóstico, Reanimación, Españ

    Sex-specific efficacy and safety of cryoballoon versus radiofrequency ablation for atrial fibrillation: An individual patient data meta-analysis

    Get PDF
    Atrial fibrillation (AF) is a growing health burden, and pulmonary vein isolation (PVI) using cryoballoon (CB) or radiofrequency (RF) represents an attractive therapeutic option. Sex-specific differences in the epidemiology, pathophysiology, and clinical presentation of AF and PVI are recognized.; We aimed at comparing the efficacy, safety, and procedural characteristics of CB and RF in women and men undergoing a first PVI procedure.; We searched for randomized controlled trials and prospective observational studies comparing CB and RF ablation with at least 1 year of follow-up. After merging individual patient data from 18 data sets, we investigated the sex-specific (procedure failure defined as recurrence of atrial arrhythmia, reablation, and reinitiation of antiarrhythmic medication), safety (periprocedural complications), and procedural characteristics of CB vs RF using Kaplan-Meier and multilevel models.; From the 18 studies, 4840 men and 1979 women were analyzed. An analysis stratified by sex correcting for several covariates showed a better efficacy of CB in men (hazard ratio for recurrence 0.88; 95% confidence interval 0.78-0.98, P = .02) but not in women (hazard ratio 0.98; 95% confidence interval 0.83-1.16; P = .82). For women and men, the energy source had no influence on the occurrence of at least 1 complication. For both sexes, the procedure time was significantly shorter with CB (-22.5 minutes for women and -27.1 minutes for men).; CB is associated with less long-term failures in men. A better understanding of AF-causal sex-specific mechanisms and refinements in CB technologies could lead to higher success rates in women

    Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial

    No full text
    International audienceBackground: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. Methods: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. Results: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. Conclusions: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02433379

    Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial

    No full text
    International audienceBackground: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. Methods: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. Results: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. Conclusions: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02433379
    corecore