4 research outputs found

    Automated office blood pressure measurements in primary care are misleading in more than one third of treated hypertensives: The VALENTINE-Greece Home Blood Pressure Monitoring study

    Get PDF
    Abstract Background This study assessed the diagnostic reliability of automated office blood pressure (OBP) measurements in treated hypertensive patients in primary care by evaluating the prevalence of white coat hypertension (WCH) and masked uncontrolled hypertension (MUCH) phenomena. Methods Primary care physicians, nationwide in Greece, assessed consecutive hypertensive patients on stable treatment using OBP (1 visit, triplicate measurements) and home blood pressure (HBP) measurements (7 days, duplicate morning and evening measurements). All measurements were performed using validated automated devices with bluetooth capacity (Omron M7 Intelli-IT). Uncontrolled OBP was defined as ≥140/90 mmHg, and uncontrolled HBP was defined as ≥135/85 mmHg. Results A total of 790 patients recruited by 135 doctors were analyzed (age: 64.5 ± 14.4 years, diabetics: 21.4%, smokers: 20.6%, and average number of antihypertensive drugs: 1.6 ± 0.8). OBP (137.5 ± 9.4/84.3 ± 7.7 mmHg, systolic/diastolic) was higher than HBP (130.6 ± 11.2/79.9 ± 8 mmHg; difference 6.9 ± 11.6/4.4 ± 7.6 mmHg, p Conclusions In primary care, automated OBP measurements are misleading in approximately 40% of treated hypertensive patients. HBP monitoring is mandatory to avoid overtreatment of subjects with WCH phenomenon and prevent undertreatment and subsequent excess cardiovascular disease in MUCH

    Serum lipids and apolipoproteins in Greek postmenopausal women: Association with estrogen, estrogen-progestin, tibolone and raloxifene therapy

    No full text
    The aim of this study was to assess lipid and apolipoprotein levels in postmenopausal women taking various regimens of replacement therapy or no therapy. Seven hundred forty-eight postmenopausal women followed in the Menopause Clinic of the, 2(nd) Department of Obstetrics and Gynecology, University of Athens, Aretaieion Hospital, were studied in a cross-sectional design. Women were either non-users of replacement therapy (no.=511) or users of one of the following regimens: conjugated equine estrogen 0.625 mg (CEE, no.=34), CEE 0.625 mg plus medroxyprogesterone acetate 5 mg (CEE/MPA, no.=60), 17beta-estradiol 2 mg plus norethisterone acetate 1 mg (E-2/NETA, no.=44), tibolone 2.5 mg (no.=84), raloxifene HCl 60 mg (no.=51). Total cholesterol (TC), LDL-cholesterol (LDL-C) and HDL-cholesterol (HDL-C), triglycerides (TG), apolipoprotein A(1) (ApoA(1)) and apolipoprotein B (ApoB) levels were assessed. Women were grouped according to replacement regimen and mean levels of lipid and apolipoproteins were compared between groups. Women in the raloxifene group were older and longer menopaused. After adjustment for age and duration of menopause; TG levels were significantly lower in the tibolone and E-2/NETA groups (75 and 89.9 mg/dl, respectively) compared to non-users. TC was lower in all therapy groups, but the difference acquired significance only in the E-2/NETA (207.8 mg/dl), compared to non-users (231.5 mg/dl). LDLC levels were significantly lower in the CEE (133.8 mg/dl), CEE/MPA (130.4 mg/dl) and raloxifene group (129.9 mg/dl) compared to non-users (151.9 mg/dl). There was no difference in HDL-C levels between users and non-users (58.9 mg/dl) except for the tibolone group where HDL-C was significantly lower (48.6 mg/dl). ApoA(1) levels were significantly higher in the CEE/MPA group (194.4 mg/dl) and significantly lower in the tibolone group (141.6 mg/dl) compared to non-users (170.4 mg/dl). No difference was detected between groups concerning ApoB levels. In conclusion, tibolone therapy is associated with lower TG levels as well as lower HDL and ApoA(1) levels. ERT, continuous combined estrogen-progestin therapy (HRT) and raloxifene are associated with lower LDL-C levels. Among continuous combined HRT users, CEE/MPA is associated with higher ApoA(1) levels, while E-2/NETA with lower TG levels. Large prospective randomized studies are required to validate these results

    Historical population declines prompted significant genomic erosion in the northern and southern white rhinoceros (Ceratotherium simum)

    No full text
    Large vertebrates are extremely sensitive to anthropogenic pressure, and their populations are declining fast. The white rhinoceros (Ceratotherium simum) is a paradigmatic case: this African megaherbivore has suffered a remarkable decline in the last 150 years due to human activities. Its subspecies, the northern (NWR) and the southern white rhinoceros (SWR), however, underwent opposite fates: the NWR vanished quickly, while the SWR recovered after the severe decline. Such demographic events are predicted to have an erosive effect at the genomic level, linked to the extirpation of diversity, and increased genetic drift and inbreeding. However, there is little empirical data available to directly reconstruct the subtleties of such processes in light of distinct demographic histories. Therefore, we generated a whole-genome, temporal data set consisting of 52 resequenced white rhinoceros genomes, representing both subspecies at two time windows: before and during/after the bottleneck. Our data reveal previously unknown population structure within both subspecies, as well as quantifiable genomic erosion. Genome-wide heterozygosity decreased significantly by 10% in the NWR and 36% in the SWR, and inbreeding coefficients rose significantly by 11% and 39%, respectively. Despite the remarkable loss of genomic diversity and recent inbreeding it suffered, the only surviving subspecies, the SWR, does not show a significant accumulation of genetic load compared to its historical counterpart. Our data provide empirical support for predictions about the genomic consequences of shrinking populations, and our findings have the potential to inform the conservation efforts of the remaining white rhinoceroses.This work was supported by ERC Consolidator Grant 681396 “Extinction Genomics” to M.T.P.G. and by EMBO Short-Term Fellowship 7578 to F.S.B. The authors would like to acknowledge support from Science for Life Laboratory, the National Genomics Infrastructure (NGI), Sweden, the Knut and Alice Wallenberg Foundation and UPPMAX for providing assistance in massively parallel DNA sequencing and computational infrastructure. The authors are very grateful to all the museums who provided samples for this study: the American Museum of Natural History, the National Museums Scotland, the Natural History Museum at the National Museum Praha, the Natural History Museum Vienna, the Powell-Cotton Museum, the Royal Museum for Central Africa Tervuren, and the Swedish Museum of Natural History

    Automated office blood pressure measurements in primary care are misleading in more than one third of treated hypertensives: The VALENTINE-Greece Home Blood Pressure Monitoring study

    No full text
    Background: This study assessed the diagnostic reliability of automated office blood pressure (OBP) measurements in treated hypertensive patients in primary care by evaluating the prevalence of white coat hypertension (WCH) and masked uncontrolled hypertension (MUCH) phenomena. Methods: Primary care physicians, nationwide in Greece, assessed consecutive hypertensive patients on stable treatment using OBP (1 visit, triplicate measurements) and home blood pressure (HBP) measurements (7 days, duplicate morning and evening measurements). All measurements were performed using validated automated devices with bluetooth capacity (Omron M7 Intelli-IT). Uncontrolled OBP was defined as ≥140/90 mmHg, and uncontrolled HBP was defined as ≥135/85 mmHg. Results: A total of 790 patients recruited by 135 doctors were analyzed (age: 64.5 ± 14.4 years, diabetics: 21.4%, smokers: 20.6%, and average number of antihypertensive drugs: 1.6 ± 0.8). OBP (137.5 ± 9.4/84.3 ± 7.7 mmHg, systolic/diastolic) was higher than HBP (130.6 ± 11.2/79.9 ± 8 mmHg; difference 6.9 ± 11.6/4.4 ± 7.6 mmHg, p < 0.001). WCH phenomenon (high OBP with low HBP) was observed in 22.7% of the patients, MUCH (low OBP with high HBP) in 15.8%, uncontrolled hypertension (high OBP with high HBP) in 29.9%, and controlled hypertension (low OBP with low HBP) in 31.6%. In multivariate logistic regression analysis, WCH was determined by stage-1 systolic hypertension (odds ratio [OR] 8.6, 95% confidence intervals [CI] 5.7, 13.1) and female gender (OR 1.6, 95% CI 1.1, 2.4), whereas MUCH was determined by high-normal systolic OBP (OR 6.2, 95% CI 3.8, 10.1) and male gender (OR 2.0, 95% CI 1.2, 3.1). Conclusions: In primary care, automated OBP measurements are misleading in approximately 40% of treated hypertensive patients. HBP monitoring is mandatory to avoid overtreatment of subjects with WCH phenomenon and prevent undertreatment and subsequent excess cardiovascular disease in MUCH. © 2019 Hellenic Society of Cardiolog
    corecore