5,643 research outputs found

    Analysis, preliminary design and simulation systems for control-structure interaction problems

    Get PDF
    Software aspects of control-structure interaction (CSI) analysis are discussed. The following subject areas are covered: (1) implementation of a partitioned algorithm for simulation of large CSI problems; (2) second-order discrete Kalman filtering equations for CSI simulations; and (3) parallel computations and control of adaptive structures

    Implementation of a partitioned algorithm for simulation of large CSI problems

    Get PDF
    The implementation of a partitioned numerical algorithm for determining the dynamic response of coupled structure/controller/estimator finite-dimensional systems is reviewed. The partitioned approach leads to a set of coupled first and second-order linear differential equations which are numerically integrated with extrapolation and implicit step methods. The present software implementation, ACSIS, utilizes parallel processing techniques at various levels to optimize performance on a shared-memory concurrent/vector processing system. A general procedure for the design of controller and filter gains is also implemented, which utilizes the vibration characteristics of the structure to be solved. Also presented are: example problems; a user's guide to the software; the procedures and algorithm scripts; a stability analysis for the algorithm; and the source code for the parallel implementation

    Single crystalline BaTiO_3 thin films synthesized using ion implantation induced layer transfer

    Get PDF
    Layer transfer of BaTiO3 thin films onto silicon-based substrates has been investigated. Hydrogen and helium ions were co-implanted to facilitate ion-implantation-induced layer transfer of films from BaTiO3 single crystals. From thermodynamic equilibrium calculations, we suggest that the dominant species during cavity nucleation and growth are H2, H+, H2O, Ba2+ and Ba–OH, and that the addition of hydrogen to the Ba–Ti–O system can effectively suppress volatile oxide formation during layer transfer and subsequent annealing. After ion implantation, BaTiO3 layers contain microstructural defects and hydrogen precipitates in the lattice, but after layer transfer, the single crystal is found to be stoichiometric. Using direct wafer bonding and layer splitting, single crystal BaTiO3 thin films were transferred onto amorphous Si3N4 and Pt substrates. Micro-Raman spectroscopy indicated that the density of defects generated by ion implantation in BaTiO3 can be significantly reduced during post-transfer annealing, returning the transferred layer to its single crystal state. Characterization using piezoresponse force microscopy shows that the layer transferred thin films are ferroelectric, with domain structures and piezoresponse characteristics similar to that of bulk crystals

    Psychoepistemology and Subjective Determinism

    Get PDF
    Senior Project submitted to The Division of Social Studies of Bard College

    Stents for transcatheter aortic valve replacement

    Get PDF
    Rheumatic heart disease (RHD) is the leading cause of aortic valve disease in the world. Surgery to repair or replace the diseased valves is the only means to save a patient's life once the disease becomes symptomatic. Transcatheter aortic valve replacement (TAVR) has revolutionised the treatment of age-related degenerative aortic valve disease, but is currently not suitable for the majority of RHD sufferers due to the rapid degeneration of flexible leaflet valves in younger patients, contraindications of commercial devices to regurgitant or non-calcific aortic valve disease, and also due to resource or funding limitations. The current research project aimed to develop and test novel compressible balloon-expandable stents suitable for patients with symptomatic rheumatic aortic valve disease, and which would allow for a percutaneous polymeric valve to be manufactured, be crimped onto balloon-based devices, and be expanded into a compliant or non-calcific native aortic valve. Several stent concepts were developed and evaluated using Finite Element Analysis (FEA) and two favoured concepts were selected for more complex FEA, in which the balloon was simulated using an Ogden material model, and rigorous testing. The stent material, a nickel-cobalt-chromium alloy, was modelled as an isotropic elasto-plastic material with isotropic hardening. The novel stent designs incorporated a native leaflet-mimicking crown shape for continuous leaflet attachment and mechanisms to anchor the stented valve within compliant aortic roots. The first of the favoured designs provided tactile location during delivery and anchored using self-expanding arms on a balloon-expandable frame of the same material ("self-locating stents"). The second design anchored using arms that protruded during deployment as a consequence of plastic deformation incurred during crimping ("expanding arm stents"). Prototypes were successfully manufactured through laser cutting and electropolishing and showed good surface quality. In vitro testing included determination of crimping and expansion behaviour and measurement of mechanical properties such as resistance to migration in the anatomy. Valve performance was evaluated through in vitro haemodynamics in a pulse duplicator and durability was tested in a high-cycle fatigue tester. Simulated use testing was performed using cadaveric animal hearts. Finally, valves were also implanted into the aortic valve position of pigs (in acute termination experiments) through a transapical approach in order to verify valve deployment behaviour and function in vivo, and determine the stent's ability to anchor in the native anatomy. Stents could be crimped to diameters below 6mm and deployed using commercial balloons and proprietary non-occlusive deployment devices. FEA simulations of stent crimping and deployment matched experimental behaviour well and provide a tool to optimise stent performance. Peak Von Mises stresses during deployment (1437 MPa and 1633 MPa for self-locating and expanding arm stents, respectively) were comparable to a "zig-zag" stent simulated for control purposes (1650 MPa). Radial strength, evaluated for expanding arm stents, was lower than the Control stent (116 N vs. 347 N). This design, although predicted to be safe under fatigue loading, had a lower fatigue safety factor than the Control stent. Stents resisted migration to forces of at least 22 N, which is four times greater than physiological loading on the valves. Polymeric valves incorporating the stents were constructed and demonstrated good in vitro haemodynamic performance (Effective Orifice Areas ≥2.0cm², ΔP<9 mmHg, regurgitation <6%) and durability of over 400 million cycles. Designs functioned as intended in simulated use tests. Valves constructed using self-locating stents could be successfully deployed without rapid pacing in eight of nine pigs, and valve position was correct in seven of these. Valves of expanding arm stents remained anchored in six of eight attempted implants in pigs. This study has demonstrated proof of concept for a novel balloon-expandable stent for a polymeric transcatheter heart valve that is capable of anchoring in a compliant native aortic valve

    Second-order discrete Kalman filtering equations for control-structure interaction simulations

    Get PDF
    A general form for the first-order representation of the continuous, second-order linear structural dynamics equations is introduced in order to derive a corresponding form of first-order Kalman filtering equations (KFE). Time integration of the resulting first-order KFE is carried out via a set of linear multistep integration formulas. It is shown that a judicious combined selection of computational paths and the undetermined matrices introduced in the general form of the first-order linear structural systems leads to a class of second-order discrete KFE involving only symmetric, N x N solution matrix
    • …
    corecore