20 research outputs found

    Watched over or over-watched? Open street CCTV in Australia

    Get PDF
    Most developed countries, Australia included, are witnessing increased government and public concerns about crime and security. Amid these anxieties, closed circuit television (CCTV) systems to monitor public spaces are increasingly being touted as a solution to problems of crime and disorder. The city of Perth established Australia’s first open street closed circuit television system in July 1991. Subsequently, there has been significant expansion. At the end of 2002 Australia had 33 “open street” CCTV schemes. Based on site inspections, extensive reviews of documentation and interviews with 22 Australian administrators, this article discusses issues relating to system implementation, management and accountability.We also suggest ways relevant authorities might ensure that current and future schemes are appropriately audited and evaluated. We argue that rigorous independent assessment of both the intended and unintended consequences of open street CCTV is essential to ensure this measure is not deployed inappropriately. Finally, this article suggests any potential crime prevention benefits must be carefully weighed against the potential of CCTV to exacerbate social division and exclusion

    Scattering of halo nuclei on heavy targets at energies around the Coulomb barrier : The case of 11Be on 197Au

    Get PDF
    This work reports on the scattering of 11Be on 197Au at energies around and below the Coulomb barrier. By experimentally identifying the elastic scattering, inelastic scattering and breakup channels, and comparing them with different calculations, valuable information on the 11Be structure and its B(E1) distribution to the continuum are obtained. On top of that, a deeper understanding of the scattering process at low energies is achieved for reactions of this kind, making these studies extendable to other loosely-bound systems like 17,19

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    The first science result with the JENSA gas-jet target: Confirmation and study of a strong subthreshold F18(p,α)O15 resonance

    Get PDF
    The astrophysical F18(p,α)O15 rate determines, in large part, the extent to which the observable radioisotope 18F is produced in novae. This rate, however, has been extremely uncertain owing to the unknown properties of a strong subthreshold resonance and its possible interference with higher-lying resonances. The new Jet Experiments in Nuclear Structure and Astrophysics (JENSA) gas-jet target has been used for the first time to determine the spin of this important resonance and significantly reduce uncertainties in the F18(p,α)O15 rate

    Performance of the Versatile Array of Neutron Detectors at Low Energy (VANDLE)

    No full text
    The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new, highly efficient plastic-scintillator array constructed for decay and transfer reaction experimental setups that require neutron detection. The versatile and modular design allows for customizable experimental setups including beta-delayed neutron spectroscopy and (d,n) transfer reactions in normal and inverse kinematics. The neutron energy and prompt-photon discrimination is determined through the time of flight technique. Fully digital data acquisition electronics and integrated triggering logic enables some VANDLE modules to achieve an intrinsic efficiency over 70% for 300-keV neutrons, measured through two different methods. A custom GEANT4 simulation models aspects of the detector array and the experimental setups to determine efficiency and detector response. A low detection threshold, due to the trigger logic and digitizing data acquisition, allowed us to measure the light-yield response curve from elastically scattered carbon nuclei inside the scintillating plastic from incident neutrons with kinetic energies below 2 MeV
    corecore