143 research outputs found

    Reinforcing the pulmonary artery autograft in the aortic position with a textile mesh: a histological evaluation

    Get PDF
    OBJECTIVES The Ross procedure involves replacing a patient’s diseased aortic valve with their own pulmonary valve. The most common failure mode is dilatation of the autograft. Various strategies to reinforce the autograft have been proposed. Personalized external aortic root support has been shown to be effective in stabilizing the aortic root in Marfan patients. In this study, the use of a similar external mesh to support a pulmonary artery autograft was evaluated. METHODS The pulmonary artery was translocated as an interposition autograft in the descending thoracic aortas of 10 sheep. The autograft was reinforced with a polyethylene terephthalate mesh (n = 7) or left unreinforced (n = 3). After 6 months, a computed tomography scan was taken, and the descending aorta was excised and histologically examined using the haematoxylin–eosin and Elastica van Gieson stains. RESULTS The autograft/aortic diameter ratio was 1.59 in the unreinforced group but much less in the reinforced group (1.11) (P < 0.05). A fibrotic sheet, variable in thickness and containing fibroblasts, neovessels and foreign body giant cells, was incorporated in the mesh. Histological examination of the reinforced autograft and the adjacent aorta revealed thinning of the vessel wall due to atrophy of the smooth muscle cells. Potential spaces between the vessel wall and the mesh were filled with oedema. CONCLUSIONS Reinforcing an interposition pulmonary autograft in the descending aorta with a macroporous mesh showed promising results in limiting autograft dilatation in this sheep model. Histological evaluation revealed atrophy of the smooth muscle cell and consequently thinning of the vessel wall within the mesh support

    Personalised external aortic root support for elective treatment of aortic root dilation in 200 patients

    Get PDF
    BACKGROUND AND OBJECTIVES: In personalised external aortic root support (PEARS), a custom-made, macroporous mesh is used to stabilise a dilated aortic root and prevent dissection, primarily in patients with genetically driven aortopathies. Data are needed on the safety and postoperative incidence of aortic events. METHODS: We present a multicentre cohort study evaluating the first 200 consecutive patients (median age 33 years) undergoing surgery with an intention to perform PEARS for aortic root dilatation in 23 centres between 2004 and 2019. Perioperative outcomes were collected prospectively while clinical follow-up was retrieved retrospectively. Median follow-up was 21.2 months. RESULTS: The main indication was Marfan syndrome (73.5%) and the most frequent concomitant procedure was mitral valve repair (10%). An intervention for myocardial ischaemia or coronary injury was needed in 11 patients, 1 case resulting in perioperative death. No ascending aortic dissections were observed in 596 documented postoperative patient years. Late reoperation was performed in 3 patients for operator failure to achieve complete mesh coverage. Among patients with at least mild aortic regurgitation (AR) preoperatively, 68% had no or trivial AR at follow-up. CONCLUSIONS: This study represents the clinical history of the first 200 patients to undergo PEARS. To date, aortic dissection has not been observed in the restrained part of the aorta, yet long-term follow-up is needed to confirm the potential of PEARS to prevent dissection. While operative mortality is low, the reported coronary complications reflect the learning curve of aortic root surgery in patients with connective tissue disease. PEARS may stabilise or reduce aortic regurgitation

    Quaternary TDM-PAM as upgrade path of access PON beyond 10Gb/s

    Get PDF
    A 20 Gb/s quaternary TDM-PAM passive optical network with chirped and non-linear optical transmitters is experimentally demonstrated. The migration from legacy TDM-PONs and the implications of using available 10 Gb/s components are analyzed. We show that a loss budget of 27.3 dB is compatible together with a packet power ratio of 10 dB between loud and soft optical network units. (c) 2012 Optical Society of Americ

    Biomechanical evaluation of a personalized external aortic root support applied in the Ross procedure

    Get PDF
    A commonly heard concern in the Ross procedure, where a diseased aortic valve is replaced by the patient's own pulmonary valve, is the possibility of pulmonary autograft dilatation. We performed a biomechanical investigation of the use of a personalized external aortic root support or exostent as a possibility for supporting the autograft. In ten sheep a short length of pulmonary artery was interposed in the descending aorta, serving as a simplified version of the Ross procedure. In seven of these cases, the autograft was supported by an external mesh or so-called exostent. Three sheep served as control, of which one was excluded from the mechanical testing. The sheep were sacrificed six months after the procedure. Samples of the relevant tissues were obtained for subsequent mechanical testing: normal aorta, normal pulmonary artery, aorta with exostent, pulmonary artery with exostent, and pulmonary artery in aortic position for six months. After mechanical testing, the material parameters of the Gasser-Ogden-Holzapfel model were determined for the different tissue types. Stress-strain curves of the different tissue types show significantly different mechanical behavior. At baseline, stress-strain curves of the pulmonary artery are lower than aortic stress-strain curves, but at the strain levels at which the collagen fibers are recruited, the pulmonary artery behaves stiffer than the aorta. After being in aortic position for six months, the pulmonary artery tends towards aorta-like behavior, indicating that growth and remodeling processes have taken place. When adding an exostent around the pulmonary autograft, the mechanical behavior of the composite artery (exostent + artery) differs from the artery alone, the non-linearity being more evident in the former

    High-quality conforming hexahedral meshes of patient-specific abdominal aortic aneurysms including their intraluminal thrombi

    Get PDF
    In order to perform finite element (FE) analyses of patient-specific abdominal aortic aneurysms, geometries derived from medical images must be meshed with suitable elements. We propose a semi-automatic method for generating conforming hexahedral meshes directly from contours segmented from medical images. Magnetic resonance images are generated using a protocol developed to give the abdominal aorta high contrast against the surrounding soft tissue. These data allow us to distinguish between the different structures of interest. We build novel quadrilateral meshes for each surface of the sectioned geometry and generate conforming hexahedral meshes by combining the quadrilateral meshes. The three-layered morphology of both the arterial wall and thrombus is incorporated using parameters determined from experiments. We demonstrate the quality of our patient-specific meshes using the element Scaled Jacobian. The method efficiently generates high-quality elements suitable for FE analysis, even in the bifurcation region of the aorta into the iliac arteries. For example, hexahedral meshes of up to 125,000 elements are generated in less than 130 s, with 94.8 % of elements well suited for FE analysis. We provide novel input for simulations by independently meshing both the arterial wall and intraluminal thrombus of the aneurysm, and their respective layered morphologies

    Multichannel 25 Gb/s low-power driver and transimpedance amplifier integrated circuits for 100 Gb/s optical links

    Get PDF
    Highly integrated electronic driver and receiver ICs with low-power consumption are essential for the development of cost-effective multichannel fiber-optic transceivers with small form factor. This paper presents the latest results of a two-channel 28 Gb/s driver array for optical duobinary modulation and a four-channel 25 Gb/s TIA array suited for both NRZ and optical duobinary detection. This paper demonstrated that 28 Gb/s duobinary signals can be efficiently generated on chip with a delay-and-add digital filter and that the driver power consumption can be significantly reduced by optimizing the drive impedance well above 50 Omega, without degrading the signal quality. To the best of our knowledge, this is the fastest modulator driver with on-chip duobinary encoding and precoding, consuming only 652 mW per channel at a differential output swing of 6 Vpp. The 4 x 25 Gb/s TIA shows a good sensitivity of - 10.3 dBm average optical input power at 25 Gb/s for PRBS 2(31) -1 and low power consumption of 77 mW per channel. Both ICs were developed in a 130 nm SiGe BiCMOS process
    • …
    corecore