79 research outputs found

    Early shift from ranibizumab to aflibercept for resistant pigment epitelial detachment in classical choroidal neovascularization

    Get PDF
    AIM: To evaluate the therapeutic effect of aflibercept in patients with suboptimal response to ranibizumab therapy in the early period.METHOD: Thirty-eight patients with wet type age related macular degeneration(W-AMD)were involved in this study. Eighteen patients with suboptimal response were shifted to 3 doses monthly intravitreal aflibercept therapy(IVA)and left 20 patients with suboptimal response went on 3 more monthly intravitreal ranibizumab(IVR). All changes were evaluated with fluorescein anigography(FA)and optical coherence tomography(OCT).RESULTS: Preoperative mean visual acuity(VA)and central macular thickness(CMT)of patients were 0.84±0.47 logMAR and 360±84 μm, respectively. One month after last IVR and IVA treatments, VA of patients were 1.1±0.34(P=0.11)logMAR and 0.48±0.37(P=0.019)logMAR and CMTs were 300±79 μm(P=0.002)and 271±51 μm(P=0.002), respectively.CONCLUSION: To eliminate repeated therapy for patients with suboptimal response to ranibizumab therapy, aflibercept might be a good alternative for early visual rehabilitation

    Segmentation and removal of fibrovascular membranes with high-speed 23 G transconjunctival sutureless vitrectomy, in severe proliferative diabetic retinopathy

    Get PDF
    AIM: To evaluate the effectiveness and safety of high-speed (5,000 cuts per minute) 23 G transconjunctival sutureless vitrectomy (TSV) in severe diabetic fibrovascular proliferation (DFVP). PATIENTS AND METHODS: In this retrospective consecutive case series, patients who underwent 23 G TSV for severe DFVP between October 2011 and March 2014 at our institution were evaluated. 23 G TSV was performed with a high-speed (5,000 cuts per minute) cutter without a chandelier light. RESULTS: The mean follow-up period was 8 months (range: 4–23 months). Of the 27 eyes of 27 patients, 14 eyes (52%) underwent concomitant phacoemulsification with posterior chamber intraocular lens implantation, nine eyes (33%) were pseudophakic, and four eyes were phakic (15%). DFVP was removed with ease in all, and visual acuity was improved in 18 (67%) eyes. Iatrogenic retinal tear was observed in four eyes (15%) and treated successfully during surgery. Suture placement to a single sclerotomy was performed in eight eyes (30%). Postoperative intraocular hemorrhage was observed in five eyes (18%). Cataract formation was observed in two of the four phakic eyes. Three (11%) patients had postoperative intraocular pressure rise. Postoperative hypotony (≤6 mmHg) and endophthalmitis were not observed in any eye. CONCLUSION: The segmentation and removal of fibrovascular membranes with high-speed 23 G TSV seems to be a safe and easy method in severe diabetic eye disease

    New semiquantitative ultrasonographic score for peripheral arterial disease assessment and its association with cardiovascular risk factors

    Get PDF
    The data concerning the distribution, extent and progression of peripheral arterial disease (PAD), as well as its association with traditional cardiovascular (CV) risk factors, have generally been obtained from studies of patients in advanced stages of the disease undergoing surgical or endovascular treatment. In this study, we have introduced a new semiquantitative ultrasonographic score (ultrasonographic lower limb atherosclerosis (ULLA) score) that is able to categorize lower limb atherosclerotic lesions at all stages of PAD. We then associated these ultrasonographic categories with a CV risk profile. We enrolled 320 consecutive subjects with symptoms suggestive of PAD or with known CV risk factors referring to our angiology unit between 1 July 2014 and 30 June 2015 for ultrasonographic evaluation of the lower limb arteries. Femoropopliteal and run-off segments were categorized together and separately based on their ultrasonographic characteristics. In univariate and multivariate analyses, the ULLA scores were significantly associated with the main CV risk factors, that is, age, male gender, cigarette smoking, arterial hypertension, diabetes, dyslipidemia, sedentary lifestyle, previous CV events and family history of CV disease, and also confirming the specific association of single risk factors with different segments of lower limb arteries. The proposed ULLA score enables a complete evaluation of the entire lower limb atherosclerotic burden, extending the results concerning the association of PAD with CV risk factors to all stages of the disease, including the early stages. It can be feasible that this new score will facilitate better evaluation of the progression of PAD and its prospective role in CV risk stratification

    Arm rotated medially with supination – the ARMS variant: description of its surgical correction

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Patients who have suffered obstetric brachial plexus injury (OBPI) have a high incidence of musculoskeletal complications stemming from the initial nerve injury. The presence of muscle imbalances and contractures leads to typical bony changes affecting the shoulder, including the SHEAR (Scapular Hypoplasia, Elevation and Rotation) deformity. The SHEAR deformity commonly occurs in conjunction with Medial Rotation Contracture (MRC) of the arm. OBPI also causes muscle imbalances at the level of the forearm, that lead to a fixed supination deformity (SD) in a small number of patients. Both MRC and SD will cause severe functional limitations without surgical intervention.</p> <p>Methods</p> <p>Fourteen OBPI patients were diagnosed with MRC of the shoulder and SD of the forearm along with SHEAR deformity during a 16 month study period, with eight patients available to long-term follow-up (age range 2.2 – 18 years). Surgical correction of the MRC was performed as a triangle tilt or humeral osteotomy depending on the age of the child, after which, the patients were treated with a radial osteotomy to correct the fixed supination deformity. Function was assessed using the modified Mallet scale, examination of apparent supination and appearance of the extremity at rest.</p> <p>Results</p> <p>Significant functional improvements were observed in patients with surgical reconstruction. Mallet score increased by an average of 5.2 (p < 0.05). Overall forearm position was not significantly changed from an average of 5° to an average of 34° maximum apparent supination after both shoulder rotation and forearm rotation corrective surgeries.</p> <p>Conclusion</p> <p>The simultaneous presence of two opposing deformities in the same limb will visually offset each other at the level of the wrist and hand, giving the false impression of neutral positioning of the limb. In reality, the neutral-appearing position of the hand indicates a fixed supination posture of the forearm in the face of a medial rotation contracture of the shoulder. Both of these deformities require surgical attention, and the presence of concurrent MRC and SD should be monitored for in OBPI patients.</p

    Synchronization and Timing in CMS HCAL

    Get PDF
    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Design, Performance and Calibration of the CMS Forward Calorimeter Wedges

    Get PDF
    We report on the test beam results and calibration methods using charged particles of the CMS Forward Calorimeter (HF). The HF calorimeter covers a large pseudorapidity region (3\l |\eta| \le 5), and is essential for large number of physics channels with missing transverse energy. It is also expected to play a prominent role in the measurement of forward tagging jets in weak boson fusion channels. The HF calorimeter is based on steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h \approx 5). This feature is also manifest in narrow and relatively short showers compared to similar calorimeters based on ionization. The choice of fused-silica optical fibers as active material is dictated by its exceptional radiation hardness. The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed in the customary form as a/\sqrt{E} + b. The stochastic term a is 198% and the constant term b is 9%. The hadronic energy resolution is largely determined by the fluctuations in the neutral pion production in showers, and when it is expressed as in the electromagnetic case, a = 280% and b = 11%

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%

    Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter

    Get PDF
    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing \et measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Despite current guidelines, intraperitoneal drain placement after elective colorectal surgery remains widespread. Drains were not associated with earlier detection of intraperitoneal collections, but were associated with prolonged hospital stay and increased risk of surgical-site infections.Background Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice. Methods COMPASS (COMPlicAted intra-abdominal collectionS after colorectal Surgery) was a prospective, international, cohort study which enrolled consecutive adults undergoing elective colorectal surgery (February to March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included: rate and time to diagnosis of postoperative intraperitoneal collections; rate of surgical site infections (SSIs); time to discharge; and 30-day major postoperative complications (Clavien-Dindo grade at least III). After propensity score matching, multivariable logistic regression and Cox proportional hazards regression were used to estimate the independent association of the secondary outcomes with drain placement. Results Overall, 1805 patients from 22 countries were included (798 women, 44.2 per cent; median age 67.0 years). The drain insertion rate was 51.9 per cent (937 patients). After matching, drains were not associated with reduced rates (odds ratio (OR) 1.33, 95 per cent c.i. 0.79 to 2.23; P = 0.287) or earlier detection (hazard ratio (HR) 0.87, 0.33 to 2.31; P = 0.780) of collections. Although not associated with worse major postoperative complications (OR 1.09, 0.68 to 1.75; P = 0.709), drains were associated with delayed hospital discharge (HR 0.58, 0.52 to 0.66; P &lt; 0.001) and an increased risk of SSIs (OR 2.47, 1.50 to 4.05; P &lt; 0.001). Conclusion Intraperitoneal drain placement after elective colorectal surgery is not associated with earlier detection of postoperative collections, but prolongs hospital stay and increases SSI risk
    corecore