31 research outputs found

    Near-field Testing of the 15-meter Model of the Hoop Column Antenna

    Get PDF
    The technical results from near-field testing of the 15-meter model of the hoop column antenna at the Martin Marietta Denver Aerospace facility are documented. The antenna consists of a deployable central column and a 15 meter hoop, stiffened by cables into a structure with a high tolerance repeatable surface and offset feed location. The surface has been configured to have four offset parabolic apertures, each about 6 meters in diameter, and is made of gold plated molybdenum wire mesh. Pattern measurements were made with feed systems radiating at frequencies of 7.73, 11.60, 2.27, 2.225, and 4.26 (all in GHz). This report (Volume 1) covers the testing from an overall viewpoint and contains information of generalized interest for testing large antennas. This volume discusses the deployment of the antenna in the Martin Facility and the measurements to determine mechanical stability and trueness of the reflector surface, gives the test program outline, and gives a synopsis of antenna electromagnetic performance. Three techniques for measuring surface mechanical tolerances were used (theodolites, metric cameras, and near-field phase), but only the near-field phase approach is included. The report also includes an error analysis. A detailed listing of the antenna patterns are provided for the 2.225 Ghz feed in Volume 3 of this report, and for all other feeds in Volume 2

    Near-field testing of the 5-meter model of the tetrahedral truss antenna

    Get PDF
    This report documents the technical results from near-field testing of the General Dynamics 5-meter model of the tetrahedral truss antenna at the Martin Marietta Denver Aerospace facility. A 5-meter square side of the tetrahedral served as the perimeter of the antenna, and a mesh surface and extensive surface contouring cord network was used to create a parabolic aperture shape to within an rms accuracy of 30 mils or better. Pattern measurements were made with offset feed systems radiating at frequencies of 7.73, 11.60, 2.27, and 4.26 (all in GHz). This report discusses the method of collecting the data, system measurement accuracy, the test data compiled, and diagostics and isolation of causes of pattern results. The technique of using near-field phase for measuring surface mechanical tolerances is included. Detailed far field antenna patterns and their implications are provided for all tests conducted

    Metabolic and respiratory costs of increasing song amplitude in zebra finches

    Get PDF
    Bird song is a widely used model in the study of animal communication and sexual selection, and several song features have been shown to reflect the quality of the singer. Recent studies have demonstrated that song amplitude may be an honest signal of current condition in males and that females prefer high amplitude songs. In addition, birds raise the amplitude of their songs to communicate in noisy environments. Although it is generally assumed that louder song should be more costly to produce, there has been little empirical evidence to support this assumption. We tested the assumption by measuring oxygen consumption and respiratory patterns in adult male zebra finches (Taeniopygia guttata) singing at different amplitudes in different background noise conditions. As background noise levels increased, birds significantly increased the sound pressure level of their songs. We found that louder songs required significantly greater subsyringeal air sac pressure than quieter songs. Though increased pressure is probably achieved by increasing respiratory muscle activity, these increases did not correlate with measurable increases in oxygen consumption. In addition, we found that oxygen consumption increased in higher background noise, independent of singing behaviour. This observation supports previous research in mammals showing that high levels of environmental noise can induce physiological stress responses. While our study did not find that increasing vocal amplitude increased metabolic costs, further research is needed to determine whether there are other non-metabolic costs of singing louder or costs associated with chronic noise exposure.Publisher PDFPeer reviewe

    Simultaneous positron emission tomography and ultrafast ultrasound for hybrid molecular, anatomical and functional imaging

    No full text
    International audiencePositron emission tomography–computed tomography (PET–CT) is the most sensitive molecular imaging modality, but it does not easily allow for rapid temporal acquisition. Ultrafast ultrasound imaging (UUI)—a recently introduced technology based on ultrasonic holography—leverages frame rates of up to several thousand images per second to quantitatively map, at high resolution, haemodynamic, biomechanical, electrophysiological and structural parameters. Here, we describe a pre-clinical scanner that registers PET–CT and UUI volumes acquired simultaneously and offers multiple combinations for imaging. We demonstrate that PET–CT–UUI allows for simultaneous images of the vasculature and metabolism during tumour growth in mice and rats, as well as for synchronized multi-modal cardiac cine-loops. Combined anatomical, functional and molecular imaging with PET–CT–UUI represents a high-performance and clinically translatable technology for biomedical research
    corecore