11 research outputs found

    Bibliography of the Museu Episcopal de Vic (1889-1991)

    Get PDF
    Des de l’aparició del decret episcopal de fundació del MEV el 1889, la bibliografia sobre el Museu ha estat força abundant. A més, en el seu context fundacional i al llarg de les seves primeres dècades de vida, bona part de la difusió cultural es vehiculà a través de publicacions de difusió reduïda, en les quals, no obstant això, es publicaren dades de gran rellevància. El present article s’ha proposat de compilar les referències bibliogràfiques relatives al MEV aparegudes durant el seu primer segle de vida (1889-1991).Since the issue of the episcopal founding decree in 1889, there has been a considerable bibliographical production about the MEV. Moreover, in its foundational context and during the first decades of its life, news concerning the Museum were spread through media of reduced geographical range, in which, however, higly relevant data were published. The present article aims to compile the bibliographical references referring to MEV during the first century of its life (1889-1991)

    Etiologies and 12-month mortality in patients with isolated involuntary weight loss at a rapid diagnostic unit

    Get PDF
    Numerous studies on involuntary weight loss (IWL) have been published since the 1980s, although most of them have included small samples of patients with specific symptoms. The aim of the present study was to determine the causes, demographic and clinical characteristics and mortality at 12 months in patients attended at a rapid diagnostic unit (RDU) for isolated IWL. A single-center retrospective observational study including all patients presenting to the RDU for isolated IWL between 2005 and 2013. The following data were recorded: demographic and clinical variables, results of complementary tests (blood tests, x-rays, computed tomography scan and digestive endoscopy), main diagnosis and vital status at 12 months. Seven hundred and ninety-one patients met the criteria for IWL. Mean age was 67.9 years (SD 4.7), 50.4% were male and mean weight loss was 8.3 kg (SD 4.7). The cause for IWL was malignant disease in 23.6% of patients, non-malignant organic disease in 44.5%, psychiatric disorder in 29.0% and unknown in 3.2%. Overall mortality at 12 months was 18.6% (95%CI: 16.1-21.6). The mortality rate was highest in the group with malignancy (61.1%; 95%CI: 54.2-68.2). Almost a quarter of all patients attended at the RDU for IWL were diagnosed with cancer. Mortality at 12 months was higher in this group than in the other three. Malignancy should therefore be ruled out during the first visit for patients attended for IWL

    Assessment of a Novel Automatic Real-Time PCR Assay on the Cobas 4800 Analyzer as a Screening Platform for Hepatitis C Virus Genotyping in Clinical Practice : Comparison with Massive Sequencing

    Get PDF
    The unequivocal identification of hepatitis C virus (HCV) subtypes 1a/1b and genotypes 2 to 6 is required for optimizing the effectiveness of interferon-free, direct-acting antiviral therapies. We compared the performance of a new real-time HCV genotyping assay used on the Cobas 4800 system (C4800) with that of high-resolution HCV subtyping (HRCS). In total, 502 samples were used, including 184 samples from chronic HCV patients (from routine laboratory activity during April 2016), 5 stored samples with double HCV genotype infections for testing the limitations of the method, and 313 samples from a screening protocol implemented in our hospital (from May to August 2016) based on the new method to further determine its genotyping accuracy. A total of 282 samples, including 171 from April 2016 (the 13 remaining had too low of a viral load for HRCS), 5 selected with double infections, and 106 from screening, were analyzed by both methods, and 220 were analyzed only by the C4800. The C4800 correctly subtyped 125 of 126 1a/1b samples, and the 1 remaining sample was reported as genotype 1. The C4800 correctly genotyped 38 of 45 non-1a/1b samples (classified by HRCS), and it reported the remaining 7 samples as indeterminate. One hundred two of 106 non-1a/1b genotype samples that were identified using the C4800 for screening were confirmed by HRCS. In the 4 remaining samples, 3 were correctly reported as genotype 1 (without defining the subtype) and 1 was reported as indeterminate. None of the samples were misgenotyped. Four of 7 samples with double HCV infections were correctly genotyped by the C4800. Excluding the 5 selected double-infected samples, the C4800 showed 95.7% concordant results for genotyping HCVs 2 to 6 and 1a/1b subtyping, and 99.2% concordance for subtyping 1a/1b single infections in clinical samples. To improve laboratory workflow, we propose using the C4800 as a first-line test for HCV genotyping and 1a/1b classification, followed by transferring non-1a/1b samples to a center where HRCS is available, if further characterization is needed

    New real-time-PCR method to identify single point mutations in hepatitis C virus

    Get PDF
    AIM: To develop a fast, low-cost diagnostic strategy to identify single point mutations in highly variable genomes such as hepatitis C virus (HCV). METHODS: In patients with HCV infection, resistance-associated amino acid substitutions within the viral quasispecies prior to therapy can confer decreased susceptibility to direct-acting antiviral agents and lead to treatment failure and virological relapse. One such naturally occurring mutation is the Q80K substitution in the HCV-NS3 protease gene, which confers resistance to PI inhibitors, particularly simeprevir. Low-cost, highly sensitive techniques enabling routine detection of these single point mutations would be useful to identify patients at a risk of treatment failure. LightCycler methods, based on real-time PCR with sequence-specific probe hybridization, have been implemented in most diagnostic laboratories. However, this technique cannot identify single point mutations in highly variable genetic environments, such as the HCV genome. To circumvent this problem, we developed a new method to homogenize all nucleotides present in a region except the point mutation of interest. RESULTS: Using nucleotide-specific probes Q, K, and R substitutions at position 80 were clearly identified at a sensitivity of 10% (mutations present at a frequency of at least 10% were detected). The technique was successfully applied to identify the Q80K substitution in 240 HCV G1 serum samples, with performance comparable to that of direct Sanger sequencing, the current standard procedure for this purpose. The new method was then validated in a Catalonian population of 202 HCV G1-infected individuals. Q80K was detected in 14.6% of G1a patients and 0% of G1b in our setting. CONCLUSION: A fast, low-cost diagnostic strategy based on real-time PCR and fluorescence resonance energy transfer probe melting curve analysis has been successfully developed to identify single point mutations in highly variable genomes such as hepatitis C virus. This technique can be adapted to detect any single point mutation in highly variable genomes.S

    Evaluation of two strategies for the interpretation of tumour markers in pleural effusions

    No full text
    Abstract Background Pleural effusions present a diagnostic challenge. Approximately 20% are associated with cancer and some 50% require invasive procedures to perform diagnosis. Determination of tumour markers may help to identify patients with malignant effusions. Two strategies are used to obtain high specificity in the differential diagnosis of malignant pleural effusions: a) high cut-off, and b) fluid/serum (F/S) ratio and low cut-off. The aim of this study is to compare these two strategies and to establish whether the identification of possible false positives using benign biomarkers – ADA, CRP and % of polymorphonuclear cells – improves diagnostic accuracy. Methods We studied 402 pleural effusions, 122 of them malignant. Benign biomarkers were determined in pleural fluid, and CEA, CA72-4, CA19-9 and CA15-3 in pleural fluid and serum. Results Establishing a cut-off value for each TM for a specificity of 100%, a joint sensitivity of 66.5% was obtained. With the F/S strategy and low cut-off points, sensitivity was 77% and specificity 98.2%, Subclassifying cases with negative benign biomarkers, both strategies achieved a specificity of 100%; sensitivity was 69.9% for single determination and 80.6% for F/S ratio. Conclusions The best interpretation of TM in the differential diagnosis of malignant pleural effusions is obtained using the F/S ratio in the group with negative benign biomarkers

    Assessment of a Novel Automatic Real-Time PCR Assay on the Cobas 4800 Analyzer as a Screening Platform for Hepatitis C Virus Genotyping in Clinical Practice: Comparison with Massive Sequencing

    No full text
    The unequivocal identification of hepatitis C virus (HCV) subtypes 1a/1b and genotypes 2 to 6 is required for optimizing the effectiveness of interferon-free, direct-acting antiviral therapies. We compared the performance of a new real-time HCV genotyping assay used on the Cobas 4800 system (C4800) with that of high-resolution HCV subtyping (HRCS). In total, 502 samples were used, including 184 samples from chronic HCV patients (from routine laboratory activity during April 2016), 5 stored samples with double HCV genotype infections for testing the limitations of the method, and 313 samples from a screening protocol implemented in our hospital (from May to August 2016) based on the new method to further determine its genotyping accuracy. A total of 282 samples, including 171 from April 2016 (the 13 remaining had too low of a viral load for HRCS), 5 selected with double infections, and 106 from screening, were analyzed by both methods, and 220 were analyzed only by the C4800. The C4800 correctly subtyped 125 of 126 1a/1b samples, and the 1 remaining sample was reported as genotype 1. The C4800 correctly genotyped 38 of 45 non-1a/1b samples (classified by HRCS), and it reported the remaining 7 samples as indeterminate. One hundred two of 106 non-1a/1b genotype samples that were identified using the C4800 for screening were confirmed by HRCS. In the 4 remaining samples, 3 were correctly reported as genotype 1 (without defining the subtype) and 1 was reported as indeterminate. None of the samples were misgenotyped. Four of 7 samples with double HCV infections were correctly genotyped by the C4800. Excluding the 5 selected double-infected samples, the C4800 showed 95.7% concordant results for genotyping HCVs 2 to 6 and 1a/1b subtyping, and 99.2% concordance for subtyping 1a/1b single infections in clinical samples. To improve laboratory workflow, we propose using the C4800 as a first-line test for HCV genotyping and 1a/1b classification, followed by transferring non-1a/1b samples to a center where HRCS is available, if further characterization is needed

    Assessment of a Novel Automatic Real-Time PCR Assay on the Cobas 4800 Analyzer as a Screening Platform for Hepatitis C Virus Genotyping in Clinical Practice : Comparison with Massive Sequencing

    No full text
    The unequivocal identification of hepatitis C virus (HCV) subtypes 1a/1b and genotypes 2 to 6 is required for optimizing the effectiveness of interferon-free, direct-acting antiviral therapies. We compared the performance of a new real-time HCV genotyping assay used on the Cobas 4800 system (C4800) with that of high-resolution HCV subtyping (HRCS). In total, 502 samples were used, including 184 samples from chronic HCV patients (from routine laboratory activity during April 2016), 5 stored samples with double HCV genotype infections for testing the limitations of the method, and 313 samples from a screening protocol implemented in our hospital (from May to August 2016) based on the new method to further determine its genotyping accuracy. A total of 282 samples, including 171 from April 2016 (the 13 remaining had too low of a viral load for HRCS), 5 selected with double infections, and 106 from screening, were analyzed by both methods, and 220 were analyzed only by the C4800. The C4800 correctly subtyped 125 of 126 1a/1b samples, and the 1 remaining sample was reported as genotype 1. The C4800 correctly genotyped 38 of 45 non-1a/1b samples (classified by HRCS), and it reported the remaining 7 samples as indeterminate. One hundred two of 106 non-1a/1b genotype samples that were identified using the C4800 for screening were confirmed by HRCS. In the 4 remaining samples, 3 were correctly reported as genotype 1 (without defining the subtype) and 1 was reported as indeterminate. None of the samples were misgenotyped. Four of 7 samples with double HCV infections were correctly genotyped by the C4800. Excluding the 5 selected double-infected samples, the C4800 showed 95.7% concordant results for genotyping HCVs 2 to 6 and 1a/1b subtyping, and 99.2% concordance for subtyping 1a/1b single infections in clinical samples. To improve laboratory workflow, we propose using the C4800 as a first-line test for HCV genotyping and 1a/1b classification, followed by transferring non-1a/1b samples to a center where HRCS is available, if further characterization is needed
    corecore