179 research outputs found

    Probing Single-Electron Spin Decoherence in Quantum Dots using Charged Excitons

    Full text link
    We propose to use optical detection of magnetic resonance (ODMR) to measure the decoherence time T_{2} of a single electron spin in a semiconductor quantum dot. The electron is in one of the spin 1/2 states and a circularly polarized laser can only create an optical excitation for one of the electron spin states due to Pauli blocking. An applied electron spin resonance (ESR) field leads to Rabi spin flips and thus to a modulation of the photoluminescence or, alternatively, of the photocurrent. This allows one to measure the ESR linewidth and the coherent Rabi oscillations, from which the electron spin decoherence can be determined. We study different possible schemes for such an ODMR setup, including cw or pulsed laser excitation.Comment: 8 pages, 7 figures. Proceedings of the PASPS3 conference, Santa Barbara, CA (USA). To appear in the Journal of Superconductivit

    The low temperature interface between the gas and solid phases of hard spheres with a short-ranged attraction

    Get PDF
    At low temperature, spheres with a very short-ranged attraction exist as a close-packed solid coexisting with an infinitely dilute gas. We find that the ratio of the interfacial tension between these two phases to the thermal energy diverges as the range of the attraction goes to zero. The large tensions when the interparticle attractions are short-ranged may be why globular proteins only crystallise over a narrow range of conditions.Comment: 6 pages, no figures (v2 has change of notation to agree with that of Stell

    Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

    Get PDF
    Purpose Assessment of calcium scoring (Ca-scoring) on a 64-slice multi-detector computed tomography (MDCT) scanner, a dual-source computed tomography (DSCT) scanner and an electron beam tomography (EBT) scanner with a moving cardiac phantom as a function of heart rate, slice thickness and calcium density. Methods and materials Three artificial arteries with inserted calcifications of different sizes and densities were scanned at rest (0 beats per minute) and at 50–110 beats per minute (bpm) with an interval of 10 bpm using 64-slice MDCT, DSCT and EBT. Images were reconstructed with a slice thickness of 0.6 and 3.0 mm. Agatston score, volume score and equivalent mass score were determined for each artery. A cardiac motion susceptibility (CMS) index was introduced to assess the susceptibility of Ca-scoring to heart rate. In addition, a difference (Δ) index was introduced to assess the difference of absolute Ca-scoring on MDCT and DSCT with EBT. Results Ca-score is relatively constant up to 60 bpm and starts to decrease or increase above 70 bpm, depending on scoring method, calcification density and slice thickness. EBT showed the least susceptibility to cardiac motion with the smallest average CMS-index (2.5). The average CMS-index of 64-slice MDCT (9.0) is approximately 2.5 times the average CMS-index of DSCT (3.6). The use of a smaller slice thickness decreases the CMS-index for both CT-modalities. The Δ-index for DSCT at 0.6 mm (53.2) is approximately 30% lower than the Δ-index for 64-slice MDCT at 0.6 mm (72.0). The Δ-indexes at 3.0 mm are approximately equal for both modalities (96.9 and 102.0 for 64-slice MDCT and DSCT respectively). Conclusion Ca-scoring is influenced by heart rate, slice thickness and modality used. Ca-scoring on DSCT is approximately 50% less susceptible to cardiac motion as 64-slice MDCT. DSCT offers a better approximation of absolute calcium score on EBT than 64-slice MDCT when using a smaller slice thickness. A smaller slice thickness reduces the susceptibility to cardiac motion and reduces the difference between CT-data and EBT-data. The best approximation of EBT on CT is found for DSCT with a slice thickness of 0.6 mm

    Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)

    Get PDF
    Purpose: To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables. Design: Cross-sectional study with repeated measurements. Materials and methods: The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC). Results: Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements. Conclusion: Inter-scan reproducibilility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter

    Advances in atomic force microscopy

    Get PDF
    This article reviews the progress of atomic force microscopy (AFM) in ultra-high vacuum, starting with its invention and covering most of the recent developments. Today, dynamic force microscopy allows to image surfaces of conductors \emph{and} insulators in vacuum with atomic resolution. The mostly used technique for atomic resolution AFM in vacuum is frequency modulation AFM (FM-AFM). This technique, as well as other dynamic AFM methods, are explained in detail in this article. In the last few years many groups have expanded the empirical knowledge and deepened the theoretical understanding of FM-AFM. Consequently, the spatial resolution and ease of use have been increased dramatically. Vacuum AFM opens up new classes of experiments, ranging from imaging of insulators with true atomic resolution to the measurement of forces between individual atoms.Comment: In press (Reviews of Modern Physics, scheduled for July 2003), 86 pages, 44 figure

    Resolving Structure and Mechanical Properties at the Nanoscale of Viruses with Frequency Modulation Atomic Force Microscopy

    Get PDF
    Structural Biology (SB) techniques are particularly successful in solving virus structures. Taking advantage of the symmetries, a heavy averaging on the data of a large number of specimens, results in an accurate determination of the structure of the sample. However, these techniques do not provide true single molecule information of viruses in physiological conditions. To answer many fundamental questions about the quickly expanding physical virology it is important to develop techniques with the capability to reach nanometer scale resolution on both structure and physical properties of individual molecules in physiological conditions. Atomic force microscopy (AFM) fulfills these requirements providing images of individual virus particles under physiological conditions, along with the characterization of a variety of properties including local adhesion and elasticity. Using conventional AFM modes is easy to obtain molecular resolved images on flat samples, such as the purple membrane, or large viruses as the Giant Mimivirus. On the contrary, small virus particles (25–50 nm) cannot be easily imaged. In this work we present Frequency Modulation atomic force microscopy (FM-AFM) working in physiological conditions as an accurate and powerful technique to study virus particles. Our interpretation of the so called “dissipation channel” in terms of mechanical properties allows us to provide maps where the local stiffness of the virus particles are resolved with nanometer resolution. FM-AFM can be considered as a non invasive technique since, as we demonstrate in our experiments, we are able to sense forces down to 20 pN. The methodology reported here is of general interest since it can be applied to a large number of biological samples. In particular, the importance of mechanical interactions is a hot topic in different aspects of biotechnology ranging from protein folding to stem cells differentiation where conventional AFM modes are already being used

    Multidimensional Atomic Force Microscopy: A Versatile Novel Technology for Nanopharmacology Research

    Get PDF
    Nanotechnology is giving us a glimpse into a nascent field of nanopharmacology that deals with pharmacological phenomena at molecular scale. This review presents our perspective on the use of scanning probe microscopy techniques with special emphasis to multidimensional atomic force microscopy (m-AFM) to explore this new field with a particular emphasis to define targets, design therapeutics, and track outcomes of molecular-scale pharmacological interactions. The approach will be to first discuss operating principles of m-AFM and provide representative examples of studies to understand human health and disease at the molecular level and then to address different strategies in defining target macromolecules, screening potential drug candidates, developing and characterizing of drug delivery systems, and monitoring target–drug interactions. Finally, we will discuss some future directions including AFM tip-based parallel sensors integrated with other high-throughput technologies which could be a powerful platform for drug discovery

    Nothing New in the (North) East? Interpreting the Rhetoric and Reality of Japanese Corporate Governance

    Get PDF
    Japan finally seems to be pulling itself out of its lost decade (and a half) of economic stagnation. Some grudgingly or triumphantly attribute this to micro-economic reforms, freeing up arthritic markets, although there is also evidence that macro-economic policy failures have been a major cause of poor performance since the 1990s. Many point to overlapping transformations in corporate governance, broadly defined to cover relationships among managers and employees as well as between firms and outside shareholders, creditors, and other stakeholders. These relationships are in flux, with moves arguably favouring shareholders and more market-driven control mechanisms. It has certainly been a found decade for law reform in Japan, particularly in corporate law, with a plethora of legislative amendments commencing around 1993 and culminating in the enactment of a consolidated Company Law in 2005. This modernisation project, particularly since 2001, is reportedly aimed at (i) securing better corporate governance, (ii) bringing the law into line with a highly-developed information society, (iii) liberalising fundraising measures, (iv) bringing corporate law into line with the internationalization of corporate activity, and (v) modernizing terms and consolidating corporate law. Because the suite of revisions has moved away from strict mandatory rules set out originally in Japan\u27s Commercial Code of 1899, modeled primarily on German law, another growing perception is that Japanese corporate law and practice is or will soon be converging significantly on US models. However, assessments remain divided as to whether these moves in corporate governance and capitalism more generally in Japan amount to a new paradigm or regime shift . Focusing primarily on quite influential commentary in English, Part I of this paper outlines two pairs of views. It concludes that the most plausible assessment is of significant but gradual transformation towards a more market-driven approach, evident also in other advanced political economies. Drawing more generally from these often virulently divided views, Part II sets out five ways forward through the proliferating literature and source material on corporate governance in Japan. Particular care must be taken in: (i) selecting the temporal timeframe, (ii) selecting countries to compare, (iii) balancing black-letter law and broader socio-economic context, (iv) reflecting on and disclosing normative preferences, and (v) giving weight to processes as well as outcomes, when assessing change in Japan - and any other country\u27s governance system. Part III ends with a call for further research particularly on law- and policy-producing processes, rather than mainly outcomes. It also outlines the usefulness of this analytical framework for analysing the broader field of Corporate Social Responsibility, now emerging as the next major area of debate and transformation in Japan - as elsewhere
    corecore