210 research outputs found

    Weak continuous monitoring of a flux qubit using coplanar waveguide resonator

    Full text link
    We study a flux qubit in a coplanar waveguide resonator by measuring transmission through the system. In our system with the flux qubit decoupled galvanically from the resonator, the intermediate coupling regime is achieved. In this regime dispersive readout is possible with weak backaction on the qubit. The detailed theoretical analysis and simulations give a good agreement with the experimental data and allow to make the qubit characterization.Comment: 4 pages, 3 figures, to be published in Phys. Rev.

    The political import of deconstruction—Derrida’s limits?: a forum on Jacques Derrida’s specters of Marx after 25 Years, part I

    Get PDF
    Jacques Derrida delivered the basis of The Specters of Marx: The State of the Debt, the Work of Mourning, & the New International as a plenary address at the conference ‘Whither Marxism?’ hosted by the University of California, Riverside, in 1993. The longer book version was published in French the same year and appeared in English and Portuguese the following year. In the decade after the publication of Specters, Derrida’s analyses provoked a large critical literature and invited both consternation and celebration by figures such as Antonio Negri, Wendy Brown and Frederic Jameson. This forum seeks to stimulate new reflections on Derrida, deconstruction and Specters of Marx by considering how the futures past announced by the book have fared after an eventful quarter century. Maja Zehfuss, Antonio Vázquez-Arroyo and Dan Bulley and Bal Sokhi-Bulley offer sharp, occasionally exasperated, meditations on the political import of deconstruction and the limits of Derrida’s diagnoses in Specters of Marx but also identify possible paths forward for a global politics taking inspiration in Derrida’s work of the 1990s

    Time- and momentum-resolved photoemission studies using time-of-flight momentum microscopy at a free-electron laser

    No full text
    Time-resolved photoemission with ultrafast pump and probe pulses is an emerging technique with wide application potential. Real-time recording of nonequilibrium electronic processes, transient states in chemical reactions, or the interplay of electronic and structural dynamics offers fascinating opportunities for future research. Combining valence-band and core-level spectroscopy with photoelectron diffraction for electronic, chemical, and structural analyses requires few 10 fs soft X-ray pulses with some 10 meV spectral resolution, which are currently available at high repetition rate free-electron lasers. We have constructed and optimized a versatile setup commissioned at FLASH/PG2 that combines free-electron laser capabilities together with a multidimensional recording scheme for photoemission studies. We use a full-field imaging momentum microscope with time-of-flight energy recording as the detector for mapping of 3D band structures in (kx, ky, E) parameter space with unprecedented efficiency. Our instrument can image full surface Brillouin zones with up to 7 Å−1 diameter in a binding-energy range of several eV, resolving about 2.5 × 105 data voxels simultaneously. Using the ultrafast excited state dynamics in the van der Waals semiconductor WSe2 measured at photon energies of 36.5 eV and 109.5 eV, we demonstrate an experimental energy resolution of 130 meV, a momentum resolution of 0.06 Å−1, and a system response function of 150 fs

    Dressed-state amplification by a superconducting qubit

    Full text link
    We demonstrate amplification of a microwave signal by a strongly driven two-level system in a coplanar waveguide resonator. The effect known from optics as dressed-state lasing is observed with a single quantum system formed by a persistent current (flux) qubit. The transmission through the resonator is enhanced when the Rabi frequency of the driven qubit is tuned into resonance with one of the resonator modes. Amplification as well as linewidth narrowing of a weak probe signal has been observed. The laser emission at the resonator's fundamental mode has been studied by measuring the emission spectrum. We analyzed our system and found an excellent agreement between the experimental results and the theoretical predictions obtained in the dressed-state model.Comment: 5 pages, 4 figure

    Examples of superconducting technology application: sensing and interfacing

    No full text
    Technological processes for the fabrication of low- and high- Tc Josephson junctions, aimed for certain applications, are described. On the one hand, the integration of low- Tc superconductor digital electronics with superconducting sensor arrays enables input signal processing with quantum limited resolution at millikelvin temperatures. We describe this mixed signal superconductor technology for analogue sensor readout and signal multiplexing for operating temperatures down to 300 mK. On the other hand, by making use of modern high- Tc Josephson junction technology, sensitive magnetometers, which require a modest cooling power, can be developed. Examples of the application of the mentioned processes are shown

    Time of flight photoelectron momentum microscopy with 80 500 MHz photon sources electron optical pulse picker or bandpass pre filter

    Get PDF
    The small time gaps of synchrotron radiation in conventional multi bunch mode 100 500 MHz or laser based sources with high pulse rate 80 MHz are prohibitive for time of flight ToF based photoelectron spectroscopy. Detectors with time resolution in the 100 ps range yield only 20 100 resolved time slices within the small time gap. Here we present two techniques of implementing efficient ToF recording at sources with high repetition rate. A fast electron optical beam blanking unit with GHz bandwidth, integrated in a photoelectron momentum microscope, allows electron optical pulse picking with any desired repetition period. Aberration free momentum distributions have been recorded at reduced pulse periods of 5 MHz at MAX II and 1.25 MHz at BESSY II . The approach is compared with two alternative solutions a bandpass pre filter here a hemispherical analyzer or a parasitic four bunch island orbit pulse train, coexisting with the multi bunch pattern on the main orbit. Chopping in the time domain or bandpass pre selection in the energy domain can both enable efficient ToF spectroscopy and photoelectron momentum microscopy at 100 500 MHz synchrotrons, highly repetitive lasers or cavity enhanced high harmonic sources. The high photon flux of a UV laser 80 MHz, lt;1 meV bandwidth facilitates momentum microscopy with an energy resolution of 4.2 meV and an analyzed region of interest ROI down to lt;800 nm. In this novel approach to sub m ARPES the ROI is defined by a small field aperture in an intermediate Gaussian image, regardless of the size of the photon spo

    Meta-analysis across Cohorts for Heart and Aging Research in Genomic Epidemiology (CHARGE) consortium provides evidence for an association of serum vitamin D with pulmonary function

    Get PDF
    The role that vitamin D plays in pulmonary function remains uncertain. Epidemiological studies reported mixed findings for serum 25-hydroxyvitamin D (25(OH)D)-pulmonary function association. We conducted the largest cross-sectional meta-analysis of the 25(OH)D-pulmonary function association to date, based on nine European ancestry (EA) cohorts (n 22 838) and five African ancestry (AA) cohorts (n 4290) in the Cohorts for Heart and Aging Research in Genomic Epidemiology Consortium. Data were analysed using linear models by cohort and ancestry. Effect modification by smoking status (current/former/never) was tested. Results were combined using fixed-effects meta-analysis. Mean serum 25(OH)D was 68 (SD 29) nmol/l for EA and 49 (SD 21) nmol/l for AA. For each 1 nmol/l higher 25(OH)D, forced expiratory volume in the 1st second (FEV1) was higher by 1.1 ml in EA (95 % CI 0.9, 1.3; P< 0.0001) and 1.8 ml (95 % CI 1.1, 2.5; P< 0.0001) in AA (P-race (difference) = 0.06), and forced vital capacity (FVC) was higher by 1.3 ml in EA (95 % CI 1.0, 1.6; P <0.0001) and 1.5 ml (95 % CI 0.8, 2.3; P= 0.0001) in AA (P-race difference = 0.56). Among EA, the 25(OH)D-FVC association was stronger in smokers: per 1 nmol/l higher 25(OH) D, FVC was higher by 1.7 ml (95 % CI 1.1, 2.3) for current smokers and 1.7 ml (95 % CI 1.2, 2.1) for former smokers, compared with 0.8 ml (95 % CI 0.4, 1.2) for never smokers. In summary, the 25(OH)D associations with FEV1 and FVC were positive in both ancestries. In EA, a stronger association was observed for smokers compared with never smokers, which supports the importance of vitamin D in vulnerable populations
    corecore