108 research outputs found

    Potential of poly(styrene-co-divinylbenzene) monolithic columns for the LC-MS analysis of protein digests

    Get PDF
    Two polystyrene-based capillary monolithic columns of different length (50 and 250 mm) were used to evaluate the effects of column length on gradient separation of protein digests. A tryptic digest of a 9-protein mixture was used as a test sample. Peak capacities were determined from selected extracted ion chromatograms, and tandem mass spectrometry data were used for database matching using the MASCOT search engine. Peak capacities and protein identification scores were higher for the long column with all gradients. Peak capacities appear to approach a plateau for longer gradient times; maximum peak capacity was estimated to be 294 for the short column and 370 for the long column. Analyses with similar gradient slope produced a ratio of the peak capacities of 3.36 for the long and the short column, which is slightly higher than the expected value of the square root of the column length ratio. The use of a longer monolith improves peptide separation, as reflected by higher peak capacity, and also increases protein identification, as observed from higher identification scores and a larger number of identified peptides. Attention has also been paid to the peak production rate (PPR, peak capacity per unit time). For short analysis times, the short column produces a higher PPR, while for analysis times longer than 40 min, the PPR of the 250-mm column is higher

    Multi-year interlaboratory exercises for the analysis of illicit drugs and metabolites in wastewater:development of a quality control system

    Get PDF
    Thirty-seven laboratories from 25 countries present the development of an inter-laboratory testing scheme for the analysis of seven illicit drug residues in standard solutions, tap- and wastewater. Almost 10 000 concentration values were evaluated: triplicates of up to five samples and 26 laboratories per year. The setup was substantially improved with experiences gained across the six repetitions (e.g. matrix type, sample conditions, spiking levels). From this, (pre-)analytical issues (e.g. pH adjustment, filtration) were revealed for specific analytes which resulted in formulation of best-practice protocols for inter-laboratory setup and analytical procedures. The results illustrate the effectiveness of the inter-laboratory setup to assess laboratory performance in the framework of wastewater-based epidemiology. The exercise proved that measurements of laboratories were of high quality (>80% satisfactory results for six out of seven analytes) and that analytical follow-up is important to assist laboratories in improving robustness of wastewater-based epidemiology results
    corecore