280 research outputs found

    Depth resolved snapshot energy-dispersive X-ray diffraction using a conical shell beam

    Get PDF
    We demonstrate a novel imaging architecture to collect range encoded diffraction patterns from overlapping samples in a single conical shell projection. The patterns were measured in the dark area encompassed by the beam via a centrally positioned aperture optically coupled to a pixelated energy-resolving detector. We show that a single exposure measurement of 0.3 mAs enables d-spacing values to be calculated. The axial positions of the samples were not required and the resultant measurements were robust in the presence of crystallographic textures. Our results demonstrate rapid volumetric materials characterization and the potential for a direct imaging method, which is of great relevance to applications in medicine, non-destructive testing and security screening

    RCS Senior Clinical Fellowship Survey: motivations, outcomes and cost of senior surgical fellowships

    Get PDF
    Completing a surgical fellowship increases specialist skills and raises the chances of securing a consultant post, but at what cost

    Multivariate calibration of energy-dispersive X-ray diffraction data for predicting the composition of pharmaceutical tablets in packaging

    Get PDF
    A system using energy-dispersive X-ray diffraction (EDXRD) has been developed and tested using multivariate calibration for the quantitative analysis of tablet-form mixtures of common pharmaceutical ingredients. A principal advantage of EDXRD over the more traditional and common angular dispersive X-ray diffraction technique (ADXRD) is the potential of EDXRD to analyse tablets within their packaging, due to the higher energy X-rays used. In the experiment, a series of caffeine, paracetamol and microcrystalline cellulose mixtures were prepared and pressed into tablets. EDXRD profiles were recorded on each sample and a principal component analysis (PCA) was carried out in both unpackaged and packaged scenarios. In both cases the first two principal components explained >98% of the between-sample variance. The PCA projected the sample profiles into two dimensional principal component space in close accordance to their ternary mixture design, demonstrating the discriminating potential of the EDXRD system. A partial least squares regression (PLSR) model was built with the samples and was validated using leave-one-out cross-validation. Low prediction errors of between 2% and 4% for both unpackaged and packaged tablets were obtained for all three chemical compounds. The prediction capability through packaging demonstrates a truly non-destructive method for quantifying tablet composition and demonstrates good potential for EDXRD to be applied in the field of counterfeit medicine screening and pharmaceutical quality control

    The Potential of Electrospinning to Enable the Realization of Energy-Autonomous Wearable Sensing Systems

    Get PDF
    The market for wearable electronic devices is experiencing significant growth and increasing potential for the future. Researchers worldwide are actively working to improve these devices, particularly in developing wearable electronics with balanced functionality and wearability for commercialization. Electrospinning, a technology that creates nano/microfiber-based membranes with high surface area, porosity, and favorable mechanical properties for human in vitro and in vivo applications using a broad range of materials, is proving to be a promising approach. Wearable electronic devices can use mechanical, thermal, evaporative and solar energy harvesting technologies to generate power for future energy needs, providing more options than traditional sources. This review offers a comprehensive analysis of how electrospinning technology can be used in energy-autonomous wearable wireless sensing systems. It provides an overview of the electrospinning technology, fundamental mechanisms, and applications in energy scavenging, human physiological signal sensing, energy storage, and antenna for data transmission. The review discusses combining wearable electronic technology and textile engineering to create superior wearable devices and increase future collaboration opportunities. Additionally, the challenges related to conducting appropriate testing for market-ready products using these devices are also discussed

    Enterprise Education Competitions: A Theoretically Flawed Intervention?

    Get PDF
    The demand for including enterprise in the education system, at all levels and for all pupils is now a global phenomenon. Within this context, the use of competitions and competitive learning activities is presented as a popular and effective vehicle for learning. The purpose of this chapter is to illustrate how a realist method of enquiry – which utilises theory as the unit of analysis – can shed new light on the assumed and unintended outcomes of enterprise education competitions. The case developed here is that there are inherent flaws in assuming that competitions will ‘work’ in the ways set out in policy and guidance. Some of the most prevalent stated outcomes – that competitions will motivate and reward young people, that they will enable the development of entrepreneurial skills, and that learners will be inspired by their peers – are challenged by theory from psychology and education. The issue at stake is that the expansion of enterprise education policy into primary and secondary education increases the likelihood that more learners will be sheep dipped in competitions, and competitive activities, without a clear recognition of the potential unintended effects. In this chapter, we employ a realist-informed approach to critically evaluate the theoretical basis that underpins the use of competitions and competitive learning activities in school-based enterprise education. We believe that our findings and subsequent recommendations will provide those who promote and practice the use of competitions with a richer, more sophisticated picture of the potential flaws within such activities.Peer reviewedFinal Published versio

    Correlation of X-ray diffraction signatures of breast tissue and their histopathological classification

    Get PDF
    This pilot study examines the correlation of X-ray diffraction (XRD) measurements with the histopathological analysis of breast tissue. Eight breast cancer samples were investigated. Each sample contained a mixture of normal and cancerous tissues. In total, 522 separate XRD measurements were made at different locations across the samples (8 in total). The resulting XRD spectra were subjected to principal component analysis (PCA) in order to determine if there were any distinguishing features that could be used to identify different tissue components. 99.0% of the variation between the spectra were described by the first two principal components (PC). Comparing the location of points in PC space with the classification determined by histopathology indicated correlation between the shape/magnitude of the XRD spectra and the tissue type. These results are encouraging and suggest that XRD could be used for the intraoperative or postoperative classification of bulk tissue samples

    Stereotactically guided breast biopsy: a review

    Get PDF
    The aims of this review are to compare and contrast the available stereotactic equipment, and to describe the variety of needle types used and their affect on pathological results and subsequent patient management. Initial stereotactic devices were “added-on” to analogue mammography units and have been replaced by prone or ducubitus equipment using digital image acquisition. Biopsies use either 14-G core biopsy (CB) needles or vacuum-assisted biopsies (VAB). Vacuum-assisted biopsy systems consistently out-perform 14-G CB with reduced need for diagnostic or multi-treatment surgery. The false-negative rate is 8% for 14-G CB compared with 0.7% for VAB. There is a risk of underestimating the disease present for lesions of uncertain malignant potential (Cat B3) and suspicious of malignancy (Cat B4) results with 25% of patients with a B3 biopsy found to have cancer at subsequent surgery and 66% of those with a B4 biopsy. A CB diagnosis of in situ malignancy is upgraded to invasive disease at surgery in 15-36% of patients undergoing CB and of the order of 10% with VAB. A high degree of diagnostic accuracy and hence safe patient care can only be achieved by meticulous attention to technique and multi-disciplinary cooperation
    corecore