3,155 research outputs found

    Model of brain maintenance reveals specific change-change association between medial-temporal lobe integrity and episodic memory

    Get PDF
    Brain maintenance has been identified as a major determinant of successful memory aging. However, the extent to which brain maintenance in support of successful memory aging is specific to memory-related brain regions or forms part of a brain-wide phenomenon is unresolved. Here, we used longitudinal brain-wide gray matter MRI volumes in 262 healthy participants aged 55 to 80 years at baseline to investigate separable dimensions of brain atrophy, and explored the links of these dimensions to different dimensions of cognitive change. We statistically adjusted for common causes of change in both brain and cognition to reveal a potentially unique signature of brain maintenance related to successful memory aging. Critically, medial temporal lobe (MTL)/hippocampal change and episodic memory change were characterized by unique, residual variance beyond general factors of change in brain and cognition, and a reliable association between these two residualized variables was established (r = 0.36, p < 0.01). The present study is the first to provide solid evidence for a specific association between changes in (MTL)/hippocampus and episodic memory in normal human aging. We conclude that hippocampus-specific brain maintenance relates to the specific preservation of episodic memory in old age, in line with the notion that brain maintenance operates at both general and domain-specific levels

    Identification and rejection of scattered neutrons in AGATA

    Full text link
    Gamma rays and neutrons, emitted following spontaneous fission of 252Cf, were measured in an AGATA experiment performed at INFN Laboratori Nazionali di Legnaro in Italy. The setup consisted of four AGATA triple cluster detectors (12 36-fold segmented high-purity germanium crystals), placed at a distance of 50 cm from the source, and 16 HELENA BaF2 detectors. The aim of the experiment was to study the interaction of neutrons in the segmented high-purity germanium detectors of AGATA and to investigate the possibility to discriminate neutrons and gamma rays with the gamma-ray tracking technique. The BaF2 detectors were used for a time-of-flight measurement, which gave an independent discrimination of neutrons and gamma rays and which was used to optimise the gamma-ray tracking-based neutron rejection methods. It was found that standard gamma-ray tracking, without any additional neutron rejection features, eliminates effectively most of the interaction points due to recoiling Ge nuclei after elastic scattering of neutrons. Standard tracking rejects also a significant amount of the events due to inelastic scattering of neutrons in the germanium crystals. Further enhancements of the neutron rejection was obtained by setting conditions on the following quantities, which were evaluated for each event by the tracking algorithm: energy of the first and second interaction point, difference in the calculated incoming direction of the gamma ray, figure-of-merit value. The experimental results of tracking with neutron rejection agree rather well with Geant4 simulations

    Apollo Lightcraft project

    Get PDF
    The detailed design of a beam-powered transatmospheric vehicle, the Apollo Lightcraft, was selected as the project for the design course. The principal goal is to reduce the LEO payload delivery cost by at least three orders of magnitude below the Space Shuttle Orbiter in the post 2020 era. The completely reusable, single-stage-to-orbit shuttlecraft will take off and land vertically, and have a reentry heat shield integrated with its lower surface. At appropriate points along the launch trajectory, the combined cycle propulsion system will transition through three or four airbreathing modes, and finally use a pure rocket mode for orbital insertion. The objective for the Spring semester propulsion source was to design and perform a detailed theoretical analysis on an advanced combined-cycle engine suitable for the Apollo Lightcraft. The preliminary theoretical analysis of this combined-cycle engine is now completed, and the acceleration performance along representative orbital trajectories was simulated. The total round trip cost is 3430or3430 or 686 per person. This represents a payload delivery cost of $3.11/lb, which is a factor of 1000 below the STS. The Apollo Lightcraft concept is now ready for a more detailed investigation during the Fall semester Transatmosphere Vehicle Design course

    Digital pulse-shape discrimination of fast neutrons and gamma rays

    Full text link
    Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator detector, and a BaF2 detector was used to collect waveforms with a 100 Ms/s, 14 bit sampling ADC. Three identical ADC's were combined to increase the sampling frequency to 300 Ms/s. Four different digital pulse-shape analysis algorithms were developed and compared to each other and to data obtained with an analogue neutron-gamma discrimination unit. Two of the digital algorithms were based on the charge comparison method, while the analogue unit and the other two digital algorithms were based on the zero-crossover method. Two different figure-of-merit parameters, which quantify the neutron-gamma discrimination properties, were evaluated for all four digital algorithms and for the analogue data set. All of the digital algorithms gave similar or better figure-of-merit values than what was obtained with the analogue setup. A detailed study of the discrimination properties as a function of sampling frequency and bit resolution of the ADC was performed. It was shown that a sampling ADC with a bit resolution of 12 bits and a sampling frequency of 100 Ms/s is adequate for achieving an optimal neutron-gamma discrimination for pulses having a dynamic range for deposited neutron energies of 0.3-12 MeV. An investigation of the influence of the sampling frequency on the time resolution was made. A FWHM of 1.7 ns was obtained at 100 Ms/s.Comment: 26 pages, 14 figures, submitted to Nuclear Instruments and Methods in Physics Research

    Cognitive and neural plasticity in aging: General and task-specific limitations

    Get PDF
    There is evidence for cognitive as well as neural plasticity across the adult life span, although aging is associated with certain constraints on plasticity. In the current paper, we argue that the age-related reduction in cognitive plasticity may be due to (a) deficits in general processing resources, and (b) failure to engage in task-relevant cognitive operations. Memory-training research suggests that age-related processing deficits (e.g., executive functions, speed) hinder older adults from utilizing mnemonic techniques as efficiently as the young, and that this age difference is reflected by diminished frontal activity during mnemonic use. Additional constraints on memory plasticity in old age are related to difficulties that are specific to the task, such as creating visual images, as well as in binding together the information to be remembered. These deficiencies are paralleled by reduced activity in occipito-parietal and medial–temporal regions, respectively. Future attempts to optimize intervention-related gains in old age should consider targeting both general processing and task-specific origins of age-associated reductions in cognitive plasticity

    Angular distribution of photons from the delay of the GDR in hot and rotating light Yb nuclei from exclusive experiments

    Get PDF
    Abstract Angular distributions of photons associated with the damping of excited-state giant dipole resonances (GDR) in hot and rotating 161,162 Yb nuclei have been measured in exclusive experiments using the HECTOR array. In reactions with heavy ions ( 48 T) angular distributions are determined as a function of the angular momentum of the compound nuclei. In reactions with lighter ions ( 17,18 O) a difference method is applied to isolate GDR decays originating from specific excitation regions. The systematics of the measured angular distributions as a function of excitation energy and angular momentum are compared to theories taking into account fluctuations of the shape and orientation of the excited nuclei
    • …
    corecore