137 research outputs found
An adjustable focusing system for a 2 MeV H- ion beam line based on permanent magnet quadrupoles
A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed,
constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ
model is realised using finite element simulations, providing an integrated
field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype
is constructed and the magnetic field is measured, demonstrating good agreement
with the simulation. Particle track simulations provide initial values for the
quadrupole positions. Accordingly, four PMQs are constructed and assembled on
the beam line, their positions are then tuned to obtain a minimal beam spot
size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam
line for an external ion beam. The novel compact design based on commercially
available NdFeB magnets allows high flexibility for ion beam applications.Comment: published in JINST (4th Feb 2013
Multiresolution fuzzy clustering of functional MRI data
Recent developments in the analysis of functional MRI data reveal a shift from hypothesis-driven statistical tests to unsupervised strategies. One of the most promising approaches is the fuzzy clustering algorithm (FCA), whose potential to detect activation patterns has already been demonstrated. But the FCA suffers from three drawbacks: first the computational complexity, second the higher sensitivity to noise and third the dependence on the random initialization. With the multiresolution approach presented here, these weak points are significantly improved, as is demonstrated in our tests with simulated and real functional MRI dat
Unwarping of Unidirectionally Distorted EPI Images
Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful further processing. So far, this aspect has been too often neglected. In this paper, we suggest a new approach using an algorithm specifically developed for the automatic registration of distorted EPI images with corresponding anatomically correct MRI images. We model the deformation field with splines, which gives us a great deal of flexibility, while comprising the affine transform as a special case. The registration criterion is least squares. Interestingly, the complexity of its evaluation does not depend on the resolution of the control grid. The spline model gives us good accuracy thanks to its high approximation order. The short support of splines leads to a fast algorithm. A multiresolution approach yields robustness and additional speed-up. The algorithm was tested on real as well as synthetic data, and the results were compared with a manual method. A wavelet-based Sobolev-type random deformation generator was developed for testing purposes. A blind test indicates that the proposed automatic method is faster, more reliable, and more precise than the manual one
A laserball calibration device for the SNO+ scintillator phase
Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale
liquid scintillator experiment that primarily aims to search for neutrinoless
double beta decay. Whilst SNO+ has light and radioactive calibration sources
external to the inner volume, an internally deployed optical source is
necessary for the full characterization of the detector model. A laser diffuser
ball developed for SNO has previously demonstrated to be an effective optical
calibration device for both SNO and SNO+ water phase. Since the introduction of
liquid scintillator for SNO+, the material compatibility, cleanliness, and
radiopurity requirements of any materials in contact with the internal medium
have increased. Improving on the original SNO laserball design, a new laserball
calibration device has been developed for the SNO+ scintillator phase with the
goal of measuring the optical properties of the detector and performing routine
PMT gain and timing calibrations. Simulations have been written to model the
diffusion properties to optimise optical and temporal performance for
calibration. Prototype laserballs have been built and characterised,
demonstrating sub-ns timing resolution and a quasi-isotropic light distributionComment: 21 pages, 16 figure
Multiplicity and transverse momentum fluctuations in inelastic proton-proton interactions at the CERN Super Proton Synchrotron
Measurements of multiplicity and transverse momentum fluctuations of charged
particles were performed in inelastic p+p interactions at 20, 31, 40, 80 and
158 GeV/c beam momentum. Results for the scaled variance of the multiplicity
distribution and for three strongly intensive measures of multiplicity and
transverse momentum fluctuations \$\Delta[P_{T},N]\$, \$\Sigma[P_{T},N]\$ and
\$\Phi_{p_T}\$ are presented. For the first time the results on fluctuations
are fully corrected for experimental biases. The results on multiplicity and
transverse momentum fluctuations significantly deviate from expectations for
the independent particle production. They also depend on charges of selected
hadrons. The string-resonance Monte Carlo models EPOS and UrQMD do not describe
the data. The scaled variance of multiplicity fluctuations is significantly
higher in inelastic p+p interactions than in central Pb+Pb collisions measured
by NA49 at the same energy per nucleon. This is in qualitative disagreement
with the predictions of the Wounded Nucleon Model. Within the statistical
framework the enhanced multiplicity fluctuations in inelastic p+p interactions
can be interpreted as due to event-by-event fluctuations of the fireball energy
and/or volume.Comment: 18 pages, 12 figure
Measurements of , , , and proton production in proton-carbon interactions at 31 GeV/ with the NA61/SHINE spectrometer at the CERN SPS
Measurements of hadron production in p+C interactions at 31 GeV/c are
performed using the NA61/ SHINE spectrometer at the CERN SPS. The analysis is
based on the full set of data collected in 2009 using a graphite target with a
thickness of 4% of a nuclear interaction length. Inelastic and production cross
sections as well as spectra of , , p, and are
measured with high precision. These measurements are essential for improved
calculations of the initial neutrino fluxes in the T2K long-baseline neutrino
oscillation experiment in Japan. A comparison of the NA61/SHINE measurements
with predictions of several hadroproduction models is presented.Comment: v1 corresponds to the preprint CERN-PH-EP-2015-278; v2 matches the
final published versio
Measurement of negatively charged pion spectra in inelastic p+p interactions at = 20, 31, 40, 80 and 158 GeV/c
We present experimental results on inclusive spectra and mean multiplicities
of negatively charged pions produced in inelastic p+p interactions at incident
projectile momenta of 20, 31, 40, 80 and 158 GeV/c ( 6.3, 7.7,
8.8, 12.3 and 17.3 GeV, respectively). The measurements were performed using
the large acceptance NA61/SHINE hadron spectrometer at the CERN Super Proton
Synchrotron.
Two-dimensional spectra are determined in terms of rapidity and transverse
momentum. Their properties such as the width of rapidity distributions and the
inverse slope parameter of transverse mass spectra are extracted and their
collision energy dependences are presented. The results on inelastic p+p
interactions are compared with the corresponding data on central Pb+Pb
collisions measured by the NA49 experiment at the CERN SPS.
The results presented in this paper are part of the NA61/SHINE ion program
devoted to the study of the properties of the onset of deconfinement and search
for the critical point of strongly interacting matter. They are required for
interpretation of results on nucleus-nucleus and proton-nucleus collisions.Comment: Numerical results available at: https://edms.cern.ch/document/1314605
Updates in v3: Updated version, as accepted for publicatio
NA61/SHINE facility at the CERN SPS: beams and detector system
NA61/SHINE (SPS Heavy Ion and Neutrino Experiment) is a multi-purpose
experimental facility to study hadron production in hadron-proton,
hadron-nucleus and nucleus-nucleus collisions at the CERN Super Proton
Synchrotron. It recorded the first physics data with hadron beams in 2009 and
with ion beams (secondary 7Be beams) in 2011.
NA61/SHINE has greatly profited from the long development of the CERN proton
and ion sources and the accelerator chain as well as the H2 beamline of the
CERN North Area. The latter has recently been modified to also serve as a
fragment separator as needed to produce the Be beams for NA61/SHINE. Numerous
components of the NA61/SHINE set-up were inherited from its predecessors, in
particular, the last one, the NA49 experiment. Important new detectors and
upgrades of the legacy equipment were introduced by the NA61/SHINE
Collaboration.
This paper describes the state of the NA61/SHINE facility - the beams and the
detector system - before the CERN Long Shutdown I, which started in March 2013
- …