6 research outputs found

    Over-expression of cbaAB genes of Bacillus stearothermophilus produces a two-subunit SoxB-type cytochrome c oxidase with proton pumping activity

    Get PDF
    AbstractWe constructed expression plasmids containing cbaAB, the structural genes for the two-subunit cytochrome bo3-type cytochrome c oxidase (SoxB type) recently isolated from a Gram-positive thermophile Bacillus stearothermophilus.B. stearothermophilus cells transformed with the plasmids over-expressed an enzymatically active bo3-type cytochrome c oxidase protein composed of the two subunits, while the transformed Escherichia coli cells produced an inactive protein composed of subunit I without subunit II. The oxidase over-expressed in B. stearothermophilus was solubilized and purified. The oxidase contained protoheme IX and heme O, as the main low-spin heme and the high-spin heme, respectively. Analysis of the substrate specificity indicated that the high-affinity site is very specific for cytochrome c-551, a cytochrome c that is a membrane-bound lipoprotein of thermophilic Bacillus. The purified enzyme reconstituted into liposomal vesicles with cytochrome c-551 showed H+ pumping activity, although the efficiency was lower than those of cytochrome aa3-type oxidases belonging to the SoxM-type

    Effects of air abrasion with alumina or glass beads on surface characteristics of CAD/CAM composite materials and the bond strength of resin cements

    Get PDF
    ABSTRACT Objective The study aimed to evaluate effects of air abrasion with alumina or glass beads on bond strengths of resin cements to CAD/CAM composite materials. Material and Methods CAD/CAM composite block materials [Cerasmart (CS) and Block HC (BHC)] were pretreated as follows: (a) no treatment (None), (b) application of a ceramic primer (CP), (c) alumina-blasting at 0.2 MPa (AB), (d) AB followed by CP (AB+CP), and (e) glass-beads blasting at 0.4 MPa (GBB) followed by CP (GBB+CP). The composite specimens were bonded to resin composite disks using resin cements [G-CEM Cerasmart (GCCS) and ResiCem (RC)]. The bond strengths after 24 h (TC 0) and after thermal cycling (TC 10,000 at 4–60°C) were measured by shear tests. Three-way ANOVA and the Tukey compromise post hoc tests were used to analyze statistically significant differences between groups (α=0.05). Results For both CAD/CAM composite materials, the None group exhibited a significant decrease in bond strength after TC 10,000 (p0.05). The AB+CP group showed a significantly higher bond strength after TC 10,000 than did the AB group for RC (p<0.05), but not for GCCS. The GBB+CP group showed the highest bond strength for both thermal cyclings (p<0.05). Conclusions Air abrasion with glass beads was more effective in increasing bond durability between the resin cements and CAD/CAM composite materials than was using an alumina powder and a CP

    Clinical effectiveness of direct resin composite restorations bonded using one-step or two-step self-etch adhesive systems : A three-year multicenter study

    Get PDF
    The purpose of this multicenter clinical study was to compare the mid-term clinical effectiveness of direct resin composite restorations using one-step or two-step self-etch adhesives (1-SEAs or 2-SEAs). In total, 352 restorations of class I–V cavities and non-carious cervical lesions in vital teeth (1-SEAs; 52 cases, 2-SEAs; 300 cases) were placed at nine university hospitals and evaluated according to the modified USPHS criteria at baseline, and after 1, 2, and 3 years. The recall rates were 86.6% (1 year), 80.1% (2 years), and 62.2% (3 years). Two restorations failed due to fracture during the follow-up, and there was no significant difference in survival rates between 1-SEAs (97.6%) and 2-SEAs (99.4%). However, 2-SEAs exhibited significantly lower occurrences of discoloration, marginal discoloration, fracture, and plaque retention. Moreover, the subjects reported a significantly lower postoperative hypersensitivity and higher overall satisfaction at all evaluation periods if 2-SEAs were used
    corecore