66 research outputs found

    Single molecule imaging with longer x-ray laser pulses

    Get PDF
    During the last five years, serial femtosecond crystallography using x-ray laser pulses has developed into a powerful technique for determining the atomic structures of protein molecules from micrometer and sub-micrometer sized crystals. One of the key reasons for this success is the "self-gating" pulse effect, whereby the x-ray laser pulses do not need to outrun all radiation damage processes. Instead, x-ray induced damage terminates the Bragg diffraction prior to the pulse completing its passage through the sample, as if the Bragg diffraction was generated by a shorter pulse of equal intensity. As a result, serial femtosecond crystallography does not need to be performed with pulses as short as 5--10 fs, as once thought, but can succeed for pulses 50--100 fs in duration. We show here that a similar gating effect applies to single molecule diffraction with respect to spatially uncorrelated damage processes like ionization and ion diffusion. The effect is clearly seen in calculations of the diffraction contrast, by calculating the diffraction of average structure separately to the diffraction from statistical fluctuations of the structure due to damage ("damage noise"). Our results suggest that sub-nanometer single molecule imaging with 30--50 fs pulses, like those produced at currently operating facilities, should not yet be ruled out. The theory we present opens up new experimental avenues to measure the impact of damage on single particle diffraction, which is needed to test damage models and to identify optimal imaging conditions.Comment: 23 pages; 5 figure

    Rapidity gaps at HERA and the Tevatron from soft colour exchanges

    Get PDF
    Models based on soft colour exchanges to rearrange colour strings in the final state provide a general framework for both diffractive and non-diffractive events in ep and hadron-hadron collisions. We study two such models and find that they can reproduce rapidity gap data from both HERA and the Tevatron. We also discuss the influence of parton cascades and multiple interactions on the results.Comment: 4 pages, 4 EPS figures, presented at UK Phenomenology Workshop on Collider Physics, Durham. Uses iopart.cl

    Progress and Poverty—1965 Version

    Get PDF
    The first hard X-ray laser, the Linac Coherent Light Source (LCLS), produces 120 shots per second. Particles injected into the X-ray beam are hit randomly and in unknown orientations by the extremely intense X-ray pulses, where the femtosecond-duration X-ray pulses diffract from the sample before the particle structure is significantly changed even though the sample is ultimately destroyed by the deposited X-ray energy. Single particle X-ray diffraction experiments generate data at the FEL repetition rate, resulting in more than 400,000 detector readouts in an hour, the data stream during an experiment contains blank frames mixed with hits on single particles, clusters and contaminants. The diffraction signal is generally weak and it is superimposed on a low but continually fluctuating background signal, originating from photon noise in the beam line and electronic noise from the detector. Meanwhile, explosion of the sample creates fragments with a characteristic signature. Here, we describe methods based on rapid image analysis combined with ion Time-of-Flight (ToF) spectroscopy of the fragments to achieve an efficient, automated and unsupervised sorting of diffraction data. The studies described here form a basis for the development of real-time frame rejection methods, e. g. for the European XFEL, which is expected to produce 100 million pulses per hour. (C)2014 Optical Society of Americ

    A statistical approach to detect protein complexes at X-ray free electron laser facilities

    Get PDF
    The Flash X-ray Imaging (FXI) technique, under development at X-ray free electron lasers (XFEL), aims to achieve structure determination based on diffraction from individual macromolecular complexes. We report an FXI study on the first protein complex-RNA polymerase II-ever injected at an XFEL. A successful 3D reconstruction requires a high number of observations of the sample in various orientations. The measured diffraction signal for many shots can be comparable to background. Here we present a robust and highly sensitive hit-identification method based on automated modeling of beamline background through photon statistics. It can operate at controlled false positive hit-rate of 3 x10(-5). We demonstrate its power in determining particle hits and validate our findings against an independent hit-identification approach based on ion time-of-flight spectra. We also validate the advantages of our method over simpler hit-identification schemes via tests on other samples and using computer simulations, showing a doubled hit-identification power

    Coherent diffraction of single Rice Dwarf virus particles using hard X-rays at the Linac Coherent Light Source

    Get PDF
    Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a wellcharacterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 mu m diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 angstrom ngstrom were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.11Ysciescopu

    Intergenerational impacts of maternal mortality: Qualitative findings from rural Malawi

    Get PDF
    Background: Maternal mortality, although largely preventable, remains unacceptably high in developing countries such as Malawi and creates a number of intergenerational impacts. Few studies have investigated the far-reaching impacts of maternal death beyond infant survival. This study demonstrates the short- and long-term impacts of maternal death on children, families, and the community in order to raise awareness of the true costs of maternal mortality and poor maternal health care in Neno, a rural and remote district in Malawi. Methods: Qualitative in-depth interviews were conducted to assess the impact of maternal mortality on child, family, and community well-being. We conducted 20 key informant interviews, 20 stakeholder interviews, and six sex-stratified focus group discussions in the seven health centers that cover the district. Transcripts were translated, coded, and analyzed in NVivo 10. Results: Participants noted a number of far-reaching impacts on orphaned children, their new caretakers, and extended families following a maternal death. Female relatives typically took on caregiving responsibilities for orphaned children, regardless of the accompanying financial hardship and frequent lack of familial or governmental support. Maternal death exacerbated children’s vulnerabilities to long-term health and social impacts related to nutrition, education, employment, early partnership, pregnancy, and caretaking. Impacts were particularly salient for female children who were often forced to take on the majority of the household responsibilities. Participants cited a number of barriers to accessing quality child health care or support services, and many were unaware of programming available to assist them in raising orphaned children or how to access these services. Conclusions: In order to both reduce preventable maternal mortality and diminish the impacts on children, extended families, and communities, our findings highlight the importance of financing and implementing universal access to emergency obstetric and neonatal care, and contraception, as well as social protection programs, including among remote populations

    Is Radiation Damage the Limiting Factor in Single Particle Imaging with X-ray Free-Electron Lasers?

    Get PDF
    The prospect of single particle imaging with atomic resolution is one of the scientific drivers for the development of X-ray free-electron lasers. The assumption since the beginning has been that damage to the sample caused by intense X-ray pulses is one of the limiting factors of coherent diffractive imaging of single particles and that X-ray pulses need to be as short as possible. Based on molecular dynamics simulations of proteins in X-ray fields of various durations (5 fs, 25 fs and 50 fs), we show that the noise in the diffracted signal caused by radiation damage is less than what can be expected from other sources, such as sample inhomogeneity and X-ray shot-to-shot variations. These findings show a different aspect of the feasibility of single particle imaging using free-electron lasers, where employing X-ray pulses of longer durations could still provide a useful diffraction signal above the noise due to the Coulomb explosion
    corecore