576 research outputs found
First electron beam polarization measurements with a Compton polarimeter at Jefferson Laboratory
A Compton polarimeter has been installed in Hall A at Jefferson Laboratory.
This letter reports on the first electron beam polarization measurements
performed during the HAPPEX experiment at an electron energy of 3.3 GeV and an
average current of 40 A. The heart of this device is a Fabry-Perot cavity
which increased the luminosity for Compton scattering in the interaction region
so much that a 1.4% statistical accuracy could be obtained within one hour,
with a 3.3% total error
A new doubly discrete analogue of smoke ring flow and the real time simulation of fluid flow
Modelling incompressible ideal fluids as a finite collection of vortex
filaments is important in physics (super-fluidity, models for the onset of
turbulence) as well as for numerical algorithms used in computer graphics for
the real time simulation of smoke. Here we introduce a time-discrete evolution
equation for arbitrary closed polygons in 3-space that is a discretisation of
the localised induction approximation of filament motion. This discretisation
shares with its continuum limit the property that it is a completely integrable
system. We apply this polygon evolution to a significant improvement of the
numerical algorithms used in Computer Graphics.Comment: 15 pages, 3 figure
A photon calorimeter using lead tungstate crystals for the CEBAF Hall A Compton polarimeter
The performances of the calorimeter of the Jlab Hall A Compton Polarimeter
have been measured using the Mainz tagged photon beam.Comment: 13 page
Common peroneal nerve palsy complicating knee dislocation and bicruciate ligaments tears
SummaryIntroductionThe occurrence rate of common peroneal nerve (CPN) palsy associated with knee dislocation or bicruciate ligament injury ranges from 10 to 40%. The present study sought first to describe the anatomic lesions encountered and their associated prognoses and second to recommend adequate treatment strategy based on a prospective multicenter observational series of knee ligament trauma cases.Material and methodsTwelve out of 67 knees treated for dislocation or bicruciate lesion presented associated CPN palsy: two females, 10 males; mean age, 32 years. Four sports injuries, three traffic accidents and five other etiologies led to seven complete dislocations and five bicruciate ruptures. Four cases involved associated popliteal artery laceration ischemia; one of the dislocations was open. Paralysis was total in eight cases and partial in four. There were two complete ruptures, three contusions with CPN in continuity stretch lesions and three macroscopically normal aspects.ResultsAt a minimum 1 year's follow-up, regardless of the initial surgical technique performed, recovery was complete in six cases, partial (in terms of motor function) in one and absent in five. Without specific CPN surgery, spontaneous recovery was partial in one case, complete in two and absent in none. Following simple emergency or secondary neurolysis, remission was total in four cases and absent in one. Three nerve grafts were all associated with non-recovery.DiscussionThe present results agree with literature findings. Palsy rates varied with trauma circumstances and departmental recruitment. Neurologic impairment was commensurate to ligamentary damages. The anatomic status of the CPN, subjected to violent traction by dislocation, was the most significant prognostic factor for neurologic recovery. In about 25% of dislocations, contusion-elongation over several centimeters was associated with as poor a prognosis as total rupture. CPN neurolysis is recommended when early clinical and EMG recovery fails to progress and/or in case of lateral ligamentary reconstruction. Possible peripheral nerve impairment needs to be included in the overall functional assessment of treatment for severe ligaments injuries and knee dislocation.Level of evidenceLevel IV, prospective study
New pixelized Micromegas detector for the COMPASS experiment
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of
the future physics projects planned by the COMPASS collaboration at CERN.
Several major upgrades compared to present detectors are being studied:
detectors standing five times higher luminosity with hadron beams, detection of
beam particles (flux up to a few hundred of kHz/mm^2, 10 times larger than for
the present detectors) with pixelized read-out in the central part, light and
integrated electronics, and improved robustness. Studies were done with the
present detectors moved in the beam, and two first pixelized prototypes are
being tested with muon and hadron beams in real conditions at COMPASS. We
present here this new project and report on two series of tests, with old
detectors moved into the beam and with pixelized prototypes operated in real
data taking condition with both muon and hadron beams.Comment: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous
Detectors conference (MPGD2009), 12-15 June 2009, Kolympari, Crete, Greece
Minor details added and language corrections don
New pixelized Micromegas detector with low discharge rate for the COMPASS experiment
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of
the future physics projects planned by the COMPASS collaboration at CERN.
Several major upgrades compared to present detectors are being studied:
detectors standing five times higher luminosity with hadron beams, detection of
beam particles (flux up to a few hundred of kHz/mm^{2}, 10 times larger than
for the present Micromegas detectors) with pixelized read-out in the central
part, light and integrated electronics, and improved robustness. Two solutions
of reduction of discharge impact have been studied, with Micromegas detectors
using resistive layers and using an additional GEM foil. Performance of such
detectors has also been measured. A large size prototypes with nominal active
area and pixelized read-out has been produced and installed at COMPASS in 2010.
In 2011 prototypes featuring an additional GEM foil, as well as an resistive
prototype, are installed at COMPASS and preliminary results from those
detectors presented very good performance. We present here the project and
report on its status, in particular the performance of large size prototypes
with an additional GEM foil.Comment: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous
Detectors conference (MPGD2011), 29-31 August 2011, Kobe, Japa
A slow-fast trait continuum at the whole community level in relation to land-use intensification
Organismal functional strategies form a continuum from slow- to fast-growing organisms, in response to common drivers such as resource availability and disturbance. However, whether there is synchronisation of these strategies at the entire community level is unclear. Here, we combine trait data for >2800 above- and belowground taxa from 14 trophic guilds spanning a disturbance and resource availability gradient in German grasslands. The results indicate that most guilds consistently respond to these drivers through both direct and trophically mediated effects, resulting in a ‘slow-fast’ axis at the level of the entire community. Using 15 indicators of carbon and nutrient fluxes, biomass production and decomposition, we also show that fast trait communities are associated with faster rates of ecosystem functioning. These findings demonstrate that ‘slow’ and ‘fast’ strategies can be manifested at the level of whole communities, opening new avenues of ecosystem-level functional classification
Fast readout of the COMPASS RICH CsI-MWPC photon chambers
Abstract A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with "slow" signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from ∼3 μs for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5–6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficient data taking at higher trigger rate
Precision Measurement of the Neutron Spin Asymmetry and Spin-Flavor Decomposition in the Valence Quark Region
We have measured the neutron spin asymmetry with high precision at
three kinematics in the deep inelastic region at , 0.47 and 0.60, and
, 3.5 and 4.8 (GeV/c), respectively. Our results unambiguously
show, for the first time, that crosses zero around and becomes
significantly positive at . Combined with the world proton data,
polarized quark distributions were extracted. Our results, in general, agree
with relativistic constituent quark models and with perturbative quantum
chromodynamics (pQCD) analyses based on the earlier data. However they deviate
from pQCD predictions based on hadron helicity conservation.Comment: 5 pages, 2 figures, this is the final version appeared in Phys. Rev.
Let
- …