Wind-induced Ground-surface Pressures Around a Single-Family House
Wind induces a ground-surface pressure field around a building that can substantially affect the flow of soil gas and thereby the entry of radon and other soil-gas contaminants into the building. To quantify the effect of the wind-induced groundsurface pressure field on contaminant entry rates, the mean ground-surface pressure field was experimentally measured in a wind tunnel for several incidence angles of the wind, two atmospheric boundary layers, and two house geometries. The experimentally measured ground-surface pressure fields are compared with those predicted by a k-e turbulence model. Despite the fundamental limitations in applying a k-e model to a system with flow separation, predictions from the numerical simulations were good for the two wind incidence angles tested
Recommended from our members
Indoor Radon and Its Decay Products: Concentrations, Causes, and Control Strategies
This report is an introduction to the behavior of radon 222 and its decay products in indoor air. This includes review of basic characteristics of radon and its decay products and of features of the indoor environment itself, all of which factors affect behavior in indoor air. The experimental and theoretical evidence on behavior of radon and its decay products is examined, providing a basis for understanding the influence of geological, structural, and meteorological factors on indoor concentrations, as well as the effectiveness of control techniques. We go on to examine three important issues concerning indoor radon. We thus include (1) an appraisal of the concentration distribution in homes, (2) an examination of the utility and limitations of popular monitoring techniques and protocols, and (3) an assessment of the key elements of strategies for controlling radon levels in homes
Recommended from our members
Indoor radon and decay products: Concentrations, causes, and control strategies
This report is another in the on going technical report series that addresses various aspects of the DOE Radon Research Program. It provides an overview of what is known about the behavior of radon and its decay products in the indoor environment and examines the manner in which several important classes of factors -- structural, geological, and meteorological -- affect indoor radon concentrations. Information on US indoor radon concentrations, currently available monitoring methods and novel radon control strategies are also explored. 238 refs., 22 figs., 9 tabs
Recommended from our members
Experimental Determination of ETS Particle Deposition in a Low Ventilation Room
Deposition on indoor surfaces is an important removal mechanism for tobacco smoke particles. We report measurements of deposition rates of environmental tobacco smoke particles in a room-size chamber. The deposition rates were determined from the changes in measured concentrations by correcting for the effects of coagulation and ventilation. The air flow turbulent intensity parameter was determined independently by measuring the air velocities in the chamber. Particles with diameters smaller than 0.25 {micro}m coagulate to form larger particles of sizes between 0.25-0.5 {micro}m. The effect of coagulation on the particles larger than 0.5 {micro}m was found to be negligible. Comparison between our measurements and calculations using Crump and Seinfeld's theory showed smaller measured deposition rates for particles from 0.1 to 0.3 {micro}m in diameter and greater measured deposition rates for particles larger than 0.6 {micro}m at three mixing intensities. Comparison of Nazaroff and Cass model for natural convection flow showed good agreement with the measurements for particles larger than 0.1 {micro}m in diameter, however, measured deposition rates exceeded model prediction by a factor of approximately four for particles in size range 0.05-0.1 {micro}m diameter. These results were used to predict deposition of sidestream smoke particles on interior surfaces. Calculations predict that in 10 hours after smoking one cigarette, 22% of total sidestream particles by mass will deposit on interior surfaces at 0.03 air change per hour (ACH), 6% will deposit at 0.5 ACH, and 3% will deposit at 1 ACH
HUMAN DISEASE FROM RADON EXPOSURES: THE IMPACT OF ENERGY CONSERVATION IN RESIDENTIAL BUILDINGS
The level of radon and its daughters inside conventional buildings is often higher than the ambient background level. Interest in conserving energy is motivating homeowners and builers to reduce ventilation and hence to increase the concentration of indoor generated air contaminants, including radon. It is unliekly that the current radiation levels in conventional homes and buildings from radon daughters could account for a significant portion of the lung cancer rate in non-smokers. However, it is likely that some increased lung cancer risk would result from increased radon exposures; hence, it is prudent not to allow radon concentrations to rise significantly. There are several ways to implement energy conservation measures without increasing risks
A Portable Wireless Particulate Sensor System for Continuous Real-Time Environmental Monitoring
Airborne particulate matter has been shown to be associated with morbidity and mortality, and may interfere with certain sensitive experiment. Understanding the levels and movements of particulate matter in an enclosed space can lead to a reduction in the impact of this material on health and experimental results. A system of environmental sensors including particulate matter, selected gasses, humidity, temperature, and pressure can be used to assist in tracking air movement, providing real-time mapping of potential contaminants as they move through a space. In this paper we present a system that is capable of sensing these environmental factors, collecting data from multiple dispersed nodes and presenting the aggregated information in real-time. The highly modular system is based on a flexible and scalable framework developed for use in aircraft cabin environments. Use of this framework enables the deployment of a custom suite of sensors with minimal development effort. Individual nodes communicate using a self-organizing mesh network and can be powered from a variety of sources, bringing a high level of flexibility in the arrangement and distribution of the sensor array. Sensor data is transmitted to a coordinator node, which then passes the time-correlated information to a server-hosted database through a choice of wired or wireless networks. Presentation software is used to either monitor the real-time data stream, or to extract records of interest from the database. A reference implementation has been created for the National Institutes of Health consisting of a custom optical particle counter and off-the-shelf sensors for CO2, CO, temperature, humidity, pressure, and acoustic noise. The total environmental sensing system provides continuous, real-time data in a readable format that can be used to analyze ambient air for events of interest
Track Reconstruction and Performance of DRIFT Directional Dark Matter Detectors using Alpha Particles
First results are presented from an analysis of data from the DRIFT-IIa and
DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha
particle tracks were reconstructed and used to characterise detector
performance--an important step towards optimising directional technology. The
drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based
on an analysis of naturally-occurring alpha-emitting background. The drift
velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the
analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction
and energy spectra were used to identify alpha particles from the decay of
Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218
progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For
Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.Comment: 27 pages, 12 figures, 5 tables. Submitted to Nuclear Instruments and
Methods in Physics Research, Section A. Subj-class: Instrumentation and
Detector
Integrating Human Indoor Air Pollutant Exposure within Life Cycle Impact Assessment
Neglecting health effects from indoor pollutant emissions and exposure, as currently done in Life Cycle Assessment (LCA), may result in product or process optimizations at the expense of workers’ or consumers’ health. To close this gap, methods for considering indoor exposure to chemicals are needed to complement the methods for outdoor human exposure assessment already in use. This paper summarizes the work of an international expert group on the integration of human indoor and outdoor exposure in LCA, within the UNEP/SETAC Life Cycle Initiative. A new methodological framework is proposed for a general procedure to include human-health effects from indoor exposure in LCA. Exposure models from occupational hygiene and household indoor air quality studies and practices are critically reviewed and recommendations are provided on the appropriateness of various model alternatives in the context of LCA. A single-compartment box model is recommended for use as a default in LCA, enabling one to screen occupational and household exposures consistent with the existing models to assess outdoor emission in a multimedia environment. An initial set of model parameter values was collected. The comparison between indoor and outdoor human exposure per unit of emission shows that for many pollutants, intake per unit of indoor emission may be several orders of magnitude higher than for outdoor emissions. It is concluded that indoor exposure should be routinely addressed within LCA
Global Intraurban Intake Fractions for Primary Air Pollutants from Vehicles and Other Distributed Sources
We model intraurban intake fraction (iF) values for distributed ground-level emissions in all 3646 global cities with more than 100,000 inhabitants, encompassing a total population of 2.0 billion. For conserved primary pollutants, population-weighted median, mean, and interquartile range iF values are 26, 39, and 14-52 ppm, respectively, where 1 ppm signifies 1 g inhaled/t emitted. The global mean urban iF reported here is roughly twice as large as previous estimates for cities in the United States and Europe. Intake fractions vary among cities owing to differences in population size, population density, and meteorology. Sorting by size, population-weighted mean iF values are 65, 35, and 15 ppm, respectively, for cities with populations larger than 3, 0.6-3, and 0.1-0.6 million. The 20 worldwide megacities (each >10 million people) have a population-weighted mean iF of 83 ppm. Mean intraurban iF values are greatest in Asia and lowest in land-rich high-income regions. Country-average iF values vary by a factor of 3 among the 10 nations with the largest urban populations
Recommended from our members
Can combining economizers with improved filtration save energy and protect equipment in data centers?
Economizer use in data centers is an energy efficiency strategy that could significantly limit electricity demand in this rapidly growing economic sector. Widespread economizer implementation, however, has been hindered by potential equipment reliability concerns associated with exposing information technology equipment to particulate matter of outdoor origin. This study explores the feasibility of using economizers in data centers to save energy while controlling particle concentrations with high-quality air filtration. Physical and chemical properties of indoor and outdoor particles were analyzed at an operating northern California data center equipped with an economizer under varying levels of air filtration efficiency. Results show that when improved filtration is used in combination with an economizer, the indoor/outdoor concentration ratios for most measured particle types were similar to levels when using conventional filtration without economizers. An energy analysis of the data center reveals that, even during the summer months, chiller savings from economizer use greatly outweigh any increase in fan power associated with improved filtration. These findings indicate that economizer use combined with improved filtration could reduce data center energy demand while providing a level of protection from particles of outdoor origin similar to that observed with conventional design
- …