    Hybrid effect of basalt fiber textile and macro polypropylene fiber on flexural load-bearing capacity and toughness of two-way concrete slabs

    Get PDF
    This paper presents an experimental study on the two-way concrete slabs with steel-free reinforcements. These include basalt fiber textile, macro polypropylene (PP) fiber and a combination of both. The plain concrete (PC) slab and steel reinforced concrete (RC) slab are studied as references. Furthermore, a comparative analysis on load bearing capacity, toughness and failure pattern of the slabs is performed. The test results indicate that the incorporation of basalt fiber textile and macro PP fibers can significantly improve load bearing capacity and toughness, and there is a positive synergetic effect between basalt fiber textile and macro PP fiber in the hybrid system. Similar to PC slab, the concrete slab reinforced with only 1-layer basalt fiber textile (BTRC1) demonstrates clearly brittle behavior. The addition of macro PP fibers may enhance the load bearing capacity in the post-peak region and convert the brittle failure pattern into a ductile one. In addition, BTRC1 slab with 8 kg/m3 macro PP fibers shows higher flexural capacity than those of RC slab with a steel ratio of 0.31%, and this implies that the combination of basalt fiber textile and macro PP fiber can be used to replace the steel mesh as a new type of durable reinforcement in structural members.National Natural Science Foundation of China (Grant No. 51578109

    Securing a Wireless Site Network to Create a BIM-allied Work-front

    Get PDF
    The Building Information Model (BIM) serves as a framework to align all the project-related data, providing interoperability to store and retrieve information interactively. Unfortunately, the construction site itself is excluded from this interaction as the large amount of data requires high data transfer rates and ruggedized hardware. However, advanced wireless communication technologies open radically new avenues to relay large amounts of data automatically and in near real-time. Construction could be a key beneficiary of these advancements. Wireless communication integrated with BIM, GPS and the Internet is able to provide the backbone necessary for creating intelligent systems, supporting the designer in his or her office as well as workers on the work-front. This paper presents a study that documents the development and testing of prototypes designed to facilitate information sharing at the field-level during construction. The main system constitutes an information hub, called the eCKiosk, connecting “senders and receivers” both on-site as well as off-site. The system design is discussed and some of the main modules are demonstrated. Since the electronic Kiosk depends on robust connections to the wireless devices distributed across the site, reliable connectivity is essential. For this reason, the discussion includes a study of the electronic signals behaviour in an ever-changing construction site. Measurements of the signal strengths during excavation and concrete work are presented and compared with theoretical calculations used to predict wave propagation. The results show how present models overestimate signal attenuation patterns on the construction site. This is important for designing a reliable and secure wireless site networks to link BIM to the work-front

    Chemical resistance of the gram-negative bacteria to different sanitizers in a water purification system

    Get PDF
    BACKGROUND: Purified water for pharmaceutical purposes must be free of microbial contamination and pyrogens. Even with the additional sanitary and disinfecting treatments applied to the system (sequential operational stages), Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas alcaligenes, Pseudomonas picketti, Flavobacterium aureum, Acinetobacter lowffi and Pseudomonas diminuta were isolated and identified from a thirteen-stage purification system. To evaluate the efficacy of the chemical agents used in the disinfecting process along with those used to adjust chemical characteristics of the system, over the identified bacteria, the kinetic parameter of killing time (D-value) necessary to inactivate 90% of the initial bioburden (decimal reduction time) was experimentally determined. METHODS: Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas alcaligenes, Pseudomonas picketti, Flavobacterium aureum, Acinetobacter lowffi and Pseudomonas diminuta were called in house (wild) bacteria. Pseudomonas diminuta ATCC 11568, Pseudomonas alcaligenes INCQS , Pseudomonas aeruginosa ATCC 15442, Pseudomonas fluorescens ATCC 3178, Pseudomonas picketti ATCC 5031, Bacillus subtilis ATCC 937 and Escherichia coli ATCC 25922 were used as 'standard' bacteria to evaluate resistance at 25°C against either 0.5% citric acid, 0.5% hydrochloric acid, 70% ethanol, 0.5% sodium bisulfite, 0.4% sodium hydroxide, 0.5% sodium hypochlorite, or a mixture of 2.2% hydrogen peroxide (H(2)O(2)) and 0.45% peracetic acid. RESULTS: The efficacy of the sanitizers varied with concentration and contact time to reduce decimal logarithmic (log(10)) population (n cycles). To kill 90% of the initial population (or one log(10 )cycle), the necessary time (D-value) was for P. aeruginosa into: (i) 0.5% citric acid, D = 3.8 min; (ii) 0.5% hydrochloric acid, D = 6.9 min; (iii) 70% ethanol, D = 9.7 min; (iv) 0.5% sodium bisulfite, D = 5.3 min; (v) 0.4% sodium hydroxide, D = 14.2 min; (vi) 0.5% sodium hypochlorite, D = 7.9 min; (vii) mixture of hydrogen peroxide (2.2%) plus peracetic acid (0.45%), D = 5.5 min. CONCLUSION: The contact time of 180 min of the system with the mixture of H(2)O(2)+ peracetic acid, a total theoretical reduction of 6 log(10 )cycles was attained in the water purified storage tank and distribution loop. The contact time between the water purification system (WPS) and the sanitary agents should be reviewed to reach sufficient bioburden reduction (over 6 log(10))

    PRImary care Streptococcal Management (PRISM) study:In vitro study, diagnostic cohorts and a pragmatic adaptive randomised controlled trial with nested qualitative study and cost-effectiveness study

    Get PDF
    Background: Antibiotics are still prescribed to most patients attending primary care with acute sore throat, despite evidence that there is modest benefit overall from antibiotics. Targeting antibiotics using either clinical scoring methods or rapid antigen detection tests (RADTs) could help. However, there is debate about which groups of streptococci are important (particularly Lancefield groups C and G), and uncertainty about the variables that most clearly predict the presence of streptococci. Objective: This study aimed to compare clinical scores or RADTs with delayed antibiotic prescribing. Design: The study comprised a RADT in vitro study; two diagnostic cohorts to develop streptococcal scores (score 1; score 2); and, finally, an open pragmatic randomised controlled trial with nested qualitative and cost-effectiveness studies. Setting: The setting was UK primary care general practices. Participants: Participants were patients aged ≥ 3 years with acute sore throat. Interventions: An internet program randomised patients to targeted antibiotic use according to (1) delayed antibiotics (control group), (2) clinical score or (3) RADT used according to clinical score. Main outcome measures: The main outcome measures were self-reported antibiotic use and symptom duration and severity on seven-point Likert scales (primary outcome: mean sore throat/difficulty swallowing score in the first 2-4 days). Results: The IMI TestPack Plus Strep A (Inverness Medical, Bedford, UK) was sensitive, specific and easy to use. Lancefield group A/C/G streptococci were found in 40% of cohort 2 and 34% of cohort 1. A five-point score predicting the presence of A/C/G streptococci [FeverPAIN: Fever; Purulence; Attend rapidly (≤ 3 days); severe Inflammation; and No cough or coryza] had moderate predictive value (bootstrapped estimates of area under receiver operating characteristic curve: 0.73 cohort 1, 0.71 cohort 2) and identified a substantial number of participants at low risk of streptococcal infection. In total, 38% of cohort 1 and 36% of cohort 2 scored ≤ 1 for FeverPAIN, associated with streptococcal percentages of 13% and 18%, respectively. In an adaptive trial design, the preliminary score (score 1; n = 1129) was replaced by FeverPAIN (n = 631). For score 1, there were no significant differences between groups. For FeverPAIN, symptom severity was documented in 80% of patients, and was lower in the clinical score group than in the delayed prescribing group (-0.33; 95% confidence interval -0.64 to -0.02; p = 0.039; equivalent to one in three rating sore throat a slight rather than moderately bad problem), and a similar reduction was observed for the RADT group (-0.30; -0.61 to 0.00; p = 0.053). Moderately bad or worse symptoms resolved significantly faster (30%) in the clinical score group (hazard ratio 1.30; 1.03 to 1.63) but not the RADT group (1.11; 0.88 to 1.40). In the delayed group, 75/164 (46%) used antibiotics, and 29% fewer used antibiotics in the clinical score group (risk ratio 0.71; 0.50 to 0.95; p = 0.018) and 27% fewer in the RADT group (0.73; 0.52 to 0.98; p = 0.033). No significant differences in complications or reconsultations were found. The clinical score group dominated both other groups for both the cost/quality-adjusted life-years and cost/change in symptom severity analyses, being both less costly and more effective, and cost-effectiveness acceptability curves indicated the clinical score to be the most likely to be cost-effective from an NHS perspective. Patients were positive about RADTs. Health professionals' concerns about test validity, the time the test took and medicalising self-limiting illness lessened after using the tests. For both RADTs and clinical scores, there were tensions with established clinical experience. Conclusions: Targeting antibiotics using a clinical score (FeverPAIN) efficiently improves symptoms and reduces antibiotic use. RADTs used in combination with FeverPAIN provide no clear advantages over FeverPAIN alone, and RADTs are unlikely to be incorporated into practice until health professionals' concerns are met and they have experience of using them. Clinical scores also face barriers related to clinicians' perceptions of their utility in the face of experience. This study has demonstrated the limitation of using one data set to develop a clinical score. FeverPAIN, derived from two data sets, appears to be valid and its use improves outcomes, but diagnostic studies to confirm the validity of FeverPAIN in other data sets and settings are needed. Experienced clinicians need to identify barriers to the use of clinical scoring methods. Implementation studies that address perceived barriers in the use of FeverPAIN are needed