504 research outputs found

    Comparison of serum levels of hepcidin and pro-hepcidin in hemodialysis patients and healthy subjects

    Get PDF
    Hepcidin prevents absorption of iron from the intestine and inhibits release of iron from macrophages and hepatocytes. For this reason, it seems that high levels of hepcidin are a predisposing factor for anemia in chronic inflammatory conditions such as chronic kidney disease and dialysis patients. This study was designed to determine the role of changes in the level of serum hepcidin in the management of hemodialysis patients. This study included 44 dialysis patients and 44 controls. The hepcidin and pro-hepcidin levels were measured by the enzyme linked immunosorbent assay method. The serum ferritin level was measured by the chemiluminescence method. The mean hepcidin level was 999.3 ± 996.7 ng/mL in the case group and 770.4 ± 815.9 ng/mL in the control group (P = 0.25). The mean pro-hepcidin level was, respectively, 186.1 ± 220.3 pg/mL and 150.87 ± 207.7 pg/mL, in the case group and control groups (P = 0.45). The mean (standard deviation) ferritin level was 816.4 ± 379.4 ng/mL in the case group and 193 ± 171.8 ng/mL in the control group (P < 0.001). In the case group, the correlation between serum ferritin and hepcidin was not significant (r = 0.6, P = 0.08). Also, there was no significant correlation between serum ferritin and pro-hepcidin levels (r = 0.6, P = 0.08). A positive correlation was seen between pro-hepcidin and hepcidin levels (r = 0.92, P < 0.01). In this study, the results showed that the serum hepcidin levels are high in dialysis patients and that there was no correlation with the serum ferritin levels

    Idiopathic Gastric Rupture in a Child: Critical Situation

    Get PDF
    Idiopathic gastric rupture is extremely rare condition in children. We report herein a 4-years-old girl with Idiopathic GR who presented with shock. Resuscitation and early surgical intervention led to saving the child's life. Index Word: Gastric rupture, Pneumoperitoneum, Abdominal distension, Resuscitation

    Medición y análisis de la impedancia en PLC de banda angosta en un ambiente universitario

    Get PDF
    Narrowband powerline communication systems are widely used in many applications, such as smart metering devices, home automation and low-speed command and control systems. However, power lines were not designed for data transmission and they represent a harsh environment for communication. In the specific bibliography, it is possible to find studies that show the diverse issues of Narrowband Powerline Communication, being the impedance of the grid one of them. The main objective of the present work is to provide a study on the impedance of the grid over this communication band. This study was done in a University environment which has a diverse number of unknown loads, considering the variation with time and location. The data acquisition system developed to conduct the study is shown. The analysis of the results shows that the local grid exhibits issues as least as severe as the ones presented by other authors in different countries and environments.Los sistemas de comunicación por la red eléctrica de banda angosta son ampliamente utilizados en aplicaciones como medidores inteligentes, automatización de hogares, y sistemas de control y comando de baja velocidad, entre otras. Sin embargo, las redes eléctricas no fueron diseñadas para transmitir datos y representan un ambiente hostil para las comunicaciones. En la bibliografía específica se encuentran estudios que evidencian las diversas problemáticas de las comunicaciones por la red eléctrica de banda angosta, siendo la impedancia una de las más importantes. El principal objetivo de este trabajo es proveer un estudio de la impedancia de la red eléctrica para esta banda de comunicación. Este estudio fue realizado en un ambiente Universitario que contiene un número diverso de cargas desconocidas, considerando las variaciones con respecto al tiempo y la ubicación. Se describe el sistema de adquisición desarrollado a medida para hacer el relevamiento. El análisis de los resultados muestra que la impedancia de la red presenta problemas para la comunicación PLC al menos tan severos como los relevados en otros estudios realizados en diferentes países y entornos

    Particle production in string cosmology models

    Get PDF
    We compute spectra of particles produced during a dilaton-driven kinetic inflation phase within string cosmology models. The resulting spectra depend on the parameters of the model and on the type of particle and are quite varied, some increasing and some decreasing with frequency. We use an approximation scheme in which all spectra can be expressed in a nice symmetric form, perhaps hinting at a deeper symmetry of the underlying physics. Our results may serve as a starting point for detailed studies of relic abundances, dark matter candidates, and possible sources of large scale anisotropy.Comment: 20 pages, no figures, latex, RevTe

    The Effects of Postoperative Physician Phone Calls for Hand and Wrist Fractures: A Prospective, Randomized Controlled Trial

    Get PDF
    Background: In this study, we sought to determine if postoperative physician phone calls following hand and wrist fracture surgery improve patient outcomes, satisfaction, and treatment adherence. Methodology: We prospectively enrolled 24 consecutive adult patients who underwent outpatient surgery for isolated hand and wrist fractures at a single, metropolitan, safety-net hospital over one year to receive an additional physician phone call starting on postoperative day one. We measured preoperative and postoperative Brief Michigan Hand Questionnaire (bMHQ) composite score, overall satisfaction on a five-point Likert scale, compliance with treatment recommendations, presence of complications, discharge instructions reading level, and clarity of discharge and follow-up instructions. The surgical team was blinded to the treatment arm. Results: The bMHQ score improved 26% after surgery; however, there was no difference in absolute score change between groups (12.2 vs. 6.5, p = 0.69). Most patients were satisfied throughout all stages of care, but postoperative satisfaction did not differ between groups (1.4 vs. 2.5, p = 0.21). There was a stronger correlation between patient hand function and satisfaction starting one month after surgery (R2 = 0.502, p = 0.002) than preoperatively (R2 = 0.252, p = 0.029). Immediately following surgery, most patients stated that discharge instructions were clear, and the average readability was below the average patient education level. Despite this, 13% removed their splint or Kirschner wires, 67% did not follow up within a week of recommendation, 62% did not complete postoperative treatment, and 33% had complications. Conclusions: Postoperative phone calls by physicians did not improve compliance with recommendations, patient-rated outcome measures, or clinical outcomes among our hand and wrist fracture patient population

    Properties of electrons scattered on a strong plane electromagnetic wave with a linear polarization: classical treatment

    Get PDF
    The relations among the components of the exit momenta of ultrarelativistic electrons scattered on a strong electromagnetic wave of a low (optical) frequency and linear polarization are established using the exact solutions to the equations of motion with radiation reaction included (the Landau-Lifshitz equation). It is found that the momentum components of the electrons traversed the electromagnetic wave depend weakly on the initial values of the momenta. These electrons are mostly scattered at the small angles to the direction of propagation of the electromagnetic wave. The maximum Lorentz factor of the electrons crossed the electromagnetic wave is proportional to the work done by the electromagnetic field and is independent of the initial momenta. The momentum component parallel to the electric field strength vector of the electromagnetic wave is determined only by the diameter of the laser beam measured in the units of the classical electron radius. As for the reflected electrons, they for the most part lose the energy, but remain relativistic. There is a reflection law for these electrons that relates the incident and the reflection angles and is independent of any parameters.Comment: 12 pp, 3 fig

    Depuración del efluente de una empresa metalúrgica utilizando un wetland construido

    Get PDF
    Los humedales o wetlands han demostrado ser altamente eficientes en la remoción de contaminantes, son de bajo costo de instalación y mantenimiento, operables por mano de obra no especializada e integrables funcionalmente con el entorno. El objetivo de este trabajo fue evaluar la eficiencia de un wetland construido para la depuración en forma conjunta del efluente industrial y el cloacal de una industria metalúrgica. Las dimensiones del mismo son de 50 m de largo por 40 m de ancho y profundidad de 80 cm, con un tabique central de manera que la relación largo-ancho sea 5:1. Está impermeabilizado con bentonita, y las plantas se arraigan sobre una capa de 1 m de suelo. Se transplantaron macrófitas de la zona del Río Paraná Medio: Eichhornia crassipes (jacinto de agua), Typha domingensis (totora) y Pontederia cordata (aguapey), entre otras. La eficiencia del humedal se determinó analizando la composición química del efluente a la entrada y salida. En sedimentos y vegetales se determinó P, Cr, Ni y Zn. El muestreo se realizó quincenalmente durante 2 años. El wetland eficientemente disminuyó las concentraciones medias y la variabilidad de los parámetros analizados, salvo en el caso de fosfato y amonio debido a la anoxia. Las remociones medias fueron de 86% para Cr, 67% para Ni, 95% para Fe, 70% para nitrato, 60% para nitrito, 78% para DQO, 77% para DBO. Las concentraciones de Zn en el afluente estuvieron por debajo de los 50 μg.l-1 en la mayoría de los muestreos. La concentración de metales no aumentó significativamente en el sedimento de fondo después de 2 años de operación. Un aumento en la concentración de metales y nutrientes en los tejidos de las macrófitas, así como también el aumento de la biomasa, representó el principal mecanismo de remoción de contaminantes. La ventaja de las macrófitas es la posibilidad de ser cosechadas, lo que conduce a importantes tasas de remoción en corto tiempo. La superficie del wetland se cubrió en un 80% de E. crassipes, lo que probablemente contribuyó a la disminución de oxígeno en agua. Disminuir el nivel de agua contribuiría a favorecer la dominancia de las macrófitas enraizadas y a aumentar la concentración de oxígeno en agua. La calidad del efluente se mejoró diseñándose la salida del mismo a nivel superficial.Facultad de Ciencias Naturales y Muse

    Depuración del efluente de una empresa metalúrgica utilizando un wetland construido

    Get PDF
    Los humedales o wetlands han demostrado ser altamente eficientes en la remoción de contaminantes, son de bajo costo de instalación y mantenimiento, operables por mano de obra no especializada e integrables funcionalmente con el entorno. El objetivo de este trabajo fue evaluar la eficiencia de un wetland construido para la depuración en forma conjunta del efluente industrial y el cloacal de una industria metalúrgica. Las dimensiones del mismo son de 50 m de largo por 40 m de ancho y profundidad de 80 cm, con un tabique central de manera que la relación largo-ancho sea 5:1. Está impermeabilizado con bentonita, y las plantas se arraigan sobre una capa de 1 m de suelo. Se transplantaron macrófitas de la zona del Río Paraná Medio: Eichhornia crassipes (jacinto de agua), Typha domingensis (totora) y Pontederia cordata (aguapey), entre otras. La eficiencia del humedal se determinó analizando la composición química del efluente a la entrada y salida. En sedimentos y vegetales se determinó P, Cr, Ni y Zn. El muestreo se realizó quincenalmente durante 2 años. El wetland eficientemente disminuyó las concentraciones medias y la variabilidad de los parámetros analizados, salvo en el caso de fosfato y amonio debido a la anoxia. Las remociones medias fueron de 86% para Cr, 67% para Ni, 95% para Fe, 70% para nitrato, 60% para nitrito, 78% para DQO, 77% para DBO. Las concentraciones de Zn en el afluente estuvieron por debajo de los 50 μg.l-1 en la mayoría de los muestreos. La concentración de metales no aumentó significativamente en el sedimento de fondo después de 2 años de operación. Un aumento en la concentración de metales y nutrientes en los tejidos de las macrófitas, así como también el aumento de la biomasa, representó el principal mecanismo de remoción de contaminantes. La ventaja de las macrófitas es la posibilidad de ser cosechadas, lo que conduce a importantes tasas de remoción en corto tiempo. La superficie del wetland se cubrió en un 80% de E. crassipes, lo que probablemente contribuyó a la disminución de oxígeno en agua. Disminuir el nivel de agua contribuiría a favorecer la dominancia de las macrófitas enraizadas y a aumentar la concentración de oxígeno en agua. La calidad del efluente se mejoró diseñándose la salida del mismo a nivel superficial.Facultad de Ciencias Naturales y Muse
    corecore