A low-noise CMOS front-end for TOF-PET
An analogue CMOS front-end for triggering and amplification of signals produced by a silicon photomultiplier (SiPM) coupled to a LYSO scintillator is proposed. The solution is intended for time-of-flight measurement in compact Positron Emission Tomography (TOF-PET) medical imaging equipments where excellent timing resolution is required (approximate to 100 ps). A CMOS 0.13 mu m technology was used to implement such front end, and the design includes preamplification, shaping, baseline holder and biasing circuitry, for a total silicon area of 500x90 mu m. Waveform sampling and time-over-threshold (ToT) techniques are under study and the front-end provides fast and shaped outputs for time and energy measurements. Post layout simulation results show that, for the trigger of a single photoelectron, the time jitter due to the pre-amplifier noise can be as low as 15 ps (FWHM), for a photodetector with a total capacitance of 70 pF. The very low input impedance of the pre-amplifier (approximate to 5 Omega) allows 1.8 ns of peaking time, at the cost of 10 mW of power consumption
A low-noise CMOS front-end for TOF-PET
An analogue CMOS front-end for triggering and amplification of signals produced by a silicon photomultiplier (SiPM) coupled to a LYSO scintillator is proposed. The solution is intended for time-of-flight measurement in compact Positron Emission Tomography (TOF-PET) medical imaging equipments where excellent timing resolution is required (approximate to 100 ps). A CMOS 0.13 mu m technology was used to implement such front end, and the design includes preamplification, shaping, baseline holder and biasing circuitry, for a total silicon area of 500x90 mu m. Waveform sampling and time-over-threshold (ToT) techniques are under study and the front-end provides fast and shaped outputs for time and energy measurements. Post layout simulation results show that, for the trigger of a single photoelectron, the time jitter due to the pre-amplifier noise can be as low as 15 ps (FWHM), for a photodetector with a total capacitance of 70 pF. The very low input impedance of the pre-amplifier (approximate to 5 Omega) allows 1.8 ns of peaking time, at the cost of 10 mW of power consumption
A low-noise CMOS front-end for TOF-PET
An analogue CMOS front-end for triggering and amplification of signals produced by a silicon photomultiplier (SiPM) coupled to a LYSO scintillator is proposed. The solution is intended for time-of-flight measurement in compact Positron Emission Tomography (TOF-PET) medical imaging equipments where excellent timing resolution is required (approximate to 100 ps). A CMOS 0.13 mu m technology was used to implement such front end, and the design includes preamplification, shaping, baseline holder and biasing circuitry, for a total silicon area of 500x90 mu m. Waveform sampling and time-over-threshold (ToT) techniques are under study and the front-end provides fast and shaped outputs for time and energy measurements. Post layout simulation results show that, for the trigger of a single photoelectron, the time jitter due to the pre-amplifier noise can be as low as 15 ps (FWHM), for a photodetector with a total capacitance of 70 pF. The very low input impedance of the pre-amplifier (approximate to 5 Omega) allows 1.8 ns of peaking time, at the cost of 10 mW of power consumption
Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging
Recently CMOS Active Pixels Sensors (APSs) have become a valuable alternative to amorphous Silicon and Selenium Flat Panel Imagers (FPIs) in bio-medical imaging applications. CMOS APSs can now be scaled up to the standard 20 cm diameter wafer size by means of a reticle stitching block process. However despite wafer scale CMOS APS being monolithic, sources of non-uniformity of response and regional variations can persist representing a significant challenge for wafer scale sensor response. Non-uniformity of stitched sensors can arise from a number of factors related to the manufacturing process, including variation of amplification, variation between readout components, wafer defects and process variations across the wafer due to manufacturing processes. This paper reports on an investigation into the spatial non-uniformity and regional variations of a wafer scale stitched CMOS APS. For the first time a per-pixel analysis of the electro-optical performance of a wafer CMOS APS is presented, to address inhomogeneity issues arising from the stitching techniques used to manufacture wafer scale sensors. A complete model of the signal generation in the pixel array has been provided and proved capable of accounting for noise and gain variations across the pixel array. This novel analysis leads to readout noise and conversion gain being evaluated at pixel level, stitching block level and in regions of interest, resulting in a coefficient of variation ≤ 1.9%. The uniformity of the image quality performance has been further investigated in a typical X-ray application, i.e. mammography, showing a uniformity in terms of CNR among the highest when compared with mammography detectors commonly used in clinical practise. Finally, in order to compare the detection capability of this novel APS with the currently used technology (i.e. FPIs), theoretical evaluation of the Detection Quantum Efficiency (DQE) at zero-frequency has been performed, resulting in a higher DQE for this detector compared to FPIs. Optical characterization, X-ray contrast measurements and theoretical DQE evaluation suggest that a trade off can be found between the need of a large imaging area and the requirement of a uniform imaging performance, making the DynAMITe large area CMOS APS suitable for a range of bio-medical applications
Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
Recent tests of a single module of the Jagiellonian Positron Emission
Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips
have proven its applicability for the detection of annihilation quanta (0.511
MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved
resolution is almost by a factor of two better with respect to the current
TOF-PET detectors and it can still be improved since, as it is shown in this
article, the intrinsic limit of time resolution for the determination of time
of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much
lower. As the major point of the article, a method allowing to record
timestamps of several photons, at two ends of the scintillator strip, by means
of matrix of silicon photomultipliers (SiPM) is introduced. As a result of
simulations, conducted with the number of SiPM varying from 4 to 42, it is
shown that the improvement of timing resolution saturates with the growing
number of photomultipliers, and that the 2 x 5 configuration at two ends
allowing to read twenty timestamps, constitutes an optimal solution. The
conducted simulations accounted for the emission time distribution, photon
transport and absorption inside the scintillator, as well as quantum efficiency
and transit time spread of photosensors, and were checked based on the
experimental results. Application of the 2 x 5 matrix of SiPM allows for
achieving the coincidence resolving time in positron emission tomography of
0.170 ns for 15 cm axial field-of-view (AFOV) and 0.365 ns
for 100 cm AFOV. The results open perspectives for construction of a
cost-effective TOF-PET scanner with significantly better TOF resolution and
larger AFOV with respect to the current TOF-PET modalities.Comment: To be published in Phys. Med. Biol. (26 pages, 17 figures
Measurement and comparison of individual external doses of high-school students living in Japan, France, Poland and Belarus -- the "D-shuttle" project --
Twelve high schools in Japan (of which six are in Fukushima Prefecture), four
in France, eight in Poland and two in Belarus cooperated in the measurement and
comparison of individual external doses in 2014. In total 216 high-school
students and teachers participated in the study. Each participant wore an
electronic personal dosimeter "D-shuttle" for two weeks, and kept a journal of
his/her whereabouts and activities. The distributions of annual external doses
estimated for each region overlap with each other, demonstrating that the
personal external individual doses in locations where residence is currently
allowed in Fukushima Prefecture and in Belarus are well within the range of
estimated annual doses due to the background radiation level of other
regions/countries
Design and construction of the MicroBooNE detector
This paper describes the design and construction of the MicroBooNE liquid
argon time projection chamber and associated systems. MicroBooNE is the first
phase of the Short Baseline Neutrino program, located at Fermilab, and will
utilize the capabilities of liquid argon detectors to examine a rich assortment
of physics topics. In this document details of design specifications, assembly
procedures, and acceptance tests are reported
Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector
Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark
matter and are expected to produce nuclear recoil (NR) events within liquid
xenon time-projection chambers. We present a measurement of the scintillation
timing characteristics of liquid xenon in the LUX dark matter detector and
develop a pulse shape discriminant to be used for particle identification. To
accurately measure the timing characteristics, we develop a template-fitting
method to reconstruct the detection times of photons. Analyzing calibration
data collected during the 2013-16 LUX WIMP search, we provide a new measurement
of the singlet-to-triplet scintillation ratio for electron recoils (ER) below
46~keV, and we make a first-ever measurement of the NR singlet-to-triplet ratio
at recoil energies below 74~keV. We exploit the difference of the photon time
spectra for NR and ER events by using a prompt fraction discrimination
parameter, which is optimized using calibration data to have the least number
of ER events that occur in a 50\% NR acceptance region. We then demonstrate how
this discriminant can be used in conjunction with the charge-to-light
discrimination to possibly improve the signal-to-noise ratio for nuclear
recoils.Comment: 16 pages, 11 figure
- …