67 research outputs found

    Deadbeat control of power leveling unit with bidirectional buck/boost DC/DC converter

    Get PDF
    As a distributed generation system increases, a stable power supply becomes difficult. Thus control of power leveling (PL) unit is required to maintain the balance of power flow for irregular power generation. The unit is required to respond to change of voltage and bidirectional power flow. So the bidirectional buck/boost DC/DC converter is applied for the control of PL unit in this research. The PL unit with Electric double-layer capacitor (EDLC) is able to absorb change of power, and it is examined whether the stable power supply is possible. The output current of PL unit is controlled so as to keep power balance and DC bus voltage. The effectiveness of the deadbeat control for power leveling unit is proved in simulation and experiment.7th International Power Electronics Conference, IPEC-Hiroshima - ECCE Asia 2014; Hiroshima; Japan; 18 May 2014 through 21 May 201

    Endoscopic Ultrasonography-Guided Gastroenterostomy Techniques for Treatment of Malignant Gastric Outlet Obstruction

    Get PDF
    Gastric outlet obstruction (GOO) can be caused by periampullary malignancies and often leads to a reduction in a patient’s quality of life. Recently, endoscopic ultrasonography-guided gastroenterostomy (EUS-GE) using a lumen-apposing self-expandable metal stent (LAMS) has been developed as a minimally invasive and durable endoscopic treatment for GOO. There are three types of EUS-GE technique: (1) the direct technique; (2) device-assisted techniques, such as a balloon catheter, nasobiliary drainage tube, and ultraslim endoscopy; and (3) EUS-guided double balloon-occluded gastrojejunostomy bypass. Previous reports of EUS-GE with LAMS have shown technical and clinical success rates (regardless of technique and etiology) of 87%–100% and 84%–100%, respectively. Studies comparing EUS-GE and surgical gastrojejunostomy have shown similar success rates, reintervention rates, and cost benefits, with a lower rate of early adverse events in EUS-GE. A comparison of EUS-GE and endoscopic enteral stent placement revealed similar technical success rates, but initial clinical success rate was higher and the rate of stent failure requiring reintervention was lower with EUS-GE

    PKN3 is the major regulator of angiogenesis and tumor metastasis in mice

    Get PDF
    PKN, a conserved family member related to PKC, was the first protein kinase identified as a target of the small GTPase Rho. PKN is involved in various functions including cytoskeletal arrangement and cell adhesion. Furthermore, the enrichment of PKN3 mRNA in some cancer cell lines as well as its requirement in malignant prostate cell growth suggested its involvement in oncogenesis. Despite intensive research efforts, physiological as well as pathological roles of PKN3 in vivo remain elusive. Here, we generated mice with a targeted deletion of PKN3. The PKN3 knockout (KO) mice are viable and develop normally. However, the absence of PKN3 had an impact on angiogenesis as evidenced by marked suppressions of micro-vessel sprouting in ex vivo aortic ring assay and in vivo corneal pocket assay. Furthermore, the PKN3 KO mice exhibited an impaired lung metastasis of melanoma cells when administered from the tail vein. Importantly, PKN3 knock-down by small interfering RNA (siRNA) induced a glycosylation defect of cell-surface glycoproteins, including ICAM-1, integrin β1 and integrin α5 in HUVECs. Our data provide the first in vivo genetic demonstration that PKN3 plays critical roles in angiogenesis and tumor metastasis, and that defective maturation of cell surface glycoproteins might underlie these phenotypes

    Confinement improvement during detached phase with RMP application in deuterium plasmas of LHD

    Get PDF
    In order to explore the compatibility of good core plasma performance with divertor heat load mitigation, the interaction between cold edge plasma and core plasma transport, including the edge transport barrier (ETB), has been analysed in the divertor detachment discharges of deuterium plasmas in LHD with resonant magnetic perturbation (RMP) field application. The RMP application introduces a widened edge stochastic layer and sharp boundary in the magnetic field structure between the confinement region and the edge stochastic layer. The widened edge stochastic layer enhances impurity radiation and provides stable detachment operation as compared with the case without RMP. It is found that ETB is formed at the confinement boundary at the onset of detachment transition. However, as the detachment deepens, the resistive pressure gradient-driven MHD mode is excited, which degrades the ETB. At the same time, however, the core transport decreases to keep global plasma stored energy (Wp) unchanged, showing clear core-edge coupling. After a gradual increase of density fluctuation during the MHD activity, a spontaneous increase of Wp and the recovery of ETB are observed while the detachment is maintained. Then, the coherent MHD mode ceases and ELM-like bursts appear. In the improved mode, impurity decontamination occurs, and the divertor heat load increases slightly. Key controlling physical processes in the interplay between core and cold edge plasma are discussed. A comparison between deuterium and hydrogen plasmas shows that hydrogen plasmas exhibit similar features to the deuterium ones in terms of density and magnetic fluctuations, impurity decontamination towards higher confinement, etc. But most of the features are modest in the hydrogen plasmas and thus no clear confinement mode transition with clear ETB formation is defined. Better global confinement is obtained in the deuterium plasmas than the hydrogen ones at a higher radiation level

    The Hayabusa Spacecraft Asteroid Multi-Band Imaging Camera: AMICA

    Full text link
    The Hayabusa Spacecraft Asteroid Multiband Imaging Camera (AMICA) has acquired more than 1400 multispectral and high-resolution images of its target asteroid, 25143 Itokawa, since late August 2005. In this paper, we summarize the design and performance of AMICA. In addition, we describe the calibration methods, assumptions, and models, based on measurements. Major calibration steps include corrections for linearity and modeling and subtraction of bias, dark current, read-out smear, and pixel-to-pixel responsivity variations. AMICA v-band data were calibrated to radiance using in-flight stellar observations. The other band data were calibrated to reflectance by comparing them to ground-based observations to avoid the uncertainty of the solar irradiation in those bands. We found that the AMICA signal was linear with respect to the input signal to an accuracy of << 1% when the signal level was < 3800 DN. We verified that the absolute radiance calibration of the AMICA v-band (0.55 micron) was accurate to 4% or less, the accuracy of the disk-integrated spectra with respect to the AMICA v-band was about 1%, and the pixel-to-pixel responsivity (flatfield) variation was 3% or less. The uncertainty in background zero-level was 5 DN. From wide-band observations of star clusters, we found that the AMICA optics have an effective focal length of 120.80 \pm 0.03 mm, yielding a field-of-view (FOV) of 5.83 deg x 5.69 deg. The resulting geometric distortion model was accurate to within a third of a pixel. We demonstrated an image-restoration technique using the point-spread functions of stars, and confirmed that the technique functions well in all loss-less images. An artifact not corrected by this calibration is scattered light associated with bright disks in the FOV.Comment: 107 pages, 22 figures, 9 tables. will appear in Icaru

    Carbon impurities behavior and its impact on ion thermal confinement in high-ion-temperature deuterium discharges on the Large Helical Device

    Get PDF
    The behavior of carbon impurities in deuterium plasmas and its impact on thermal confinement were investigated in comparison with hydrogen plasmas in the Large Helical Device (LHD). Deuterium plasma experiments have been started in the LHD and high-ion-temperature plasmas with central ion temperature (T i) of 10 keV were successfully obtained. The thermal confinement improvement could be sustained for a longer time compared with hydrogen plasmas. An isotope effect was observed in the time evolution of the carbon density profiles. A transiently peaked profile was observed in the deuterium plasmas due to the smaller carbon convection velocity and diffusivity in the deuterium plasmas compared with the hydrogen plasmas. The peaked carbon density profile was strongly correlated to the ion thermal confinement improvement. The peaking of the carbon density profile will be one of the clues to clarify the unexplained mechanisms for the formations of ion internal transport barrier and impurity hole on LHD. These results could also lead to a better understanding of the isotope effect in the thermal confinement in torus plasma

    Transport characteristics of deuterium and hydrogen plasmas with ion internal transport barrier in the Large Helical Device

    Get PDF
    A remarkable extension of the high-ion-temperature (high-Ti) regime was obtained in deuterium plasma experiments in the Large Helical Device. In order to clarify transport characteristics in the ion internal transport barrier (ITB) formation with an isotope effect, a dataset of pure deuterium (nD/ne  >  0.8) and pure hydrogen (nH/ne  >  0.8) plasmas in the high-Ti regime were analyzed, and two mechanisms of transport improvement were characterized. A significant reduction of ion heat transport in the core of both deuterium and hydrogen plasmas was observed, indicating ion ITB formation. The dependence of the ion heat diffusivity on temperature ratio (Te/Ti) and normalized Ti-gradient (R/LTi  =  −(R/Ti)(dTi/dr)) was investigated in the core region, in which gyrokinetic simulations with the GKV code predict the destabilization of ion temperature gradient (ITG) modes. The Te/Ti dependence shows ITG-like property, while a significant deviation from the ITG-like property is found in the R/ dependence, indicating suppression of the ITG mode in the large R/ regime and resultant ion ITB formation. In the comparison between deuterium plasma and hydrogen plasma, the lower transport in the deuterium plasma is observed in both ion and electron heat diffusivities, indicating a significant isotope effect. It was found with the nonlinear turbulent transport simulation with GKV that the zonal flow enhancement contributes to the ITG suppression in the deuterium plasma

    Japanese multicenter database of healthy controls for [¹²³I]FP-CIT SPECT

    Get PDF
    Purpose: The aim of this multicenter trial was to generate a [¹²³I]FP-CIT SPECT database of healthy controls from the common SPECT systems available in Japan. Methods: This study included 510 sets of SPECT data from 256 healthy controls (116 men and 140 women; age range, 30–83 years) acquired from eight different centers. Images were reconstructed without attenuation or scatter correction (NOACNOSC), with only attenuation correction using the Chang method (ChangACNOSC) or X-ray CT (CTACNOSC), and with both scatter and attenuation correction using the Chang method (ChangACSC) or X-ray CT (CTACSC). These SPECT images were analyzed using the Southampton method. The outcome measure was the specific binding ratio (SBR) in the striatum. These striatal SBRs were calibrated from prior experiments using a striatal phantom. Results: The original SBRs gradually decreased in the order of ChangACSC, CTACSC, ChangACNOSC, CTACNOSC, and NOACNOSC. The SBRs for NOACNOSC were 46% lower than those for ChangACSC. In contrast, the calibrated SBRs were almost equal under no scatter correction (NOSC) conditions. A significant effect of age was found, with an SBR decline rate of 6.3% per decade. In the 30–39 age group, SBRs were 12.2% higher in women than in men, but this increase declined with age and was absent in the 70–79 age group. Conclusions: This study provided a large-scale quantitative database of [¹²³I]FP-CIT SPECT scans from different scanners in healthy controls across a wide age range and with balanced sex representation. The phantom calibration effectively harmonizes SPECT data from different SPECT systems under NOSC conditions. The data collected in this study may serve as a reference database

    The isotope effect on impurities and bulk ion particle transport in the Large Helical Device

    Get PDF
    The isotope effect on impurities and bulk ion particle transport is investigated by using the deuterium, hydrogen, and isotope mixture plasma in the Large Helical Device (LHD). A clear isotope effect is observed in the impurity transport but not the bulk ion transport. The isotope effects on impurity transport and ion heat transport are observed as a primary and a secondary effect, respectively, in the plasma with an internal transport barrier (ITB). In the LHD, an ion ITB is always transient because the impurity hole triggered by the increase of ion temperature gradient causes the enhancement of ion heat transport and gradually terminates the ion ITB. The formation of an impurity hole becomes slower in the deuterium (D) plasma than the hydrogen (H) plasma. This primary isotope effect on impurity transport contributes the longer sustainment of the ion ITB state because the low ion thermal diffusivity can be sustained as long as the normalized carbon impurity gradient R/Ln,c, where , is above the critical value (~−5). Therefore, the longer sustainment of the ITB state in the deuterium plasma is considered to be a secondary isotope effect due to the mitigation of the impurity hole. The radial profile of H and D ion density is measured using bulk charge exchange spectroscopy inside the isotope mixture plasma. The decay time of H ion density after the H-pellet injection and the decay time of D ion density after D-pellet injection are almost identical, which demonstrates that there is no significant isotope effect on ion particle transport

    Realization of high Ti plasmas and confinement characteristics of ITB plasmas in the LHD deuterium experiments

    Get PDF
    The deuterium (D) operation was initiated in the LHD in 2017. In the first campaign of the D experiments, we successfully extended the high temperature regime in the LHD. The new record of the ion temperature (Ti) of 10 keV associated with the ion internal transport barrier (ITB) was achieved due to several operational optimization. The thermal confinement characteristics of ITB plasmas were compared between hydrogen and D discharges. The effective ion thermal diffusivity of the ion-ITB plasmas was found to be smaller in the D discharges than that in the H discharges. The profiles of the Ti, the electron density, and the impurity of the high Ti plasmas strongly depended on the magnetic configuration and these profiles tended to peaked in the inward-shifted configuration. It was also found that the electron thermal confinement of the electron-ITB plasmas was clearly improved in the deuterium case. The GKV simulation showed the linear growth rate of TEM/ITG reduced in the plasmas with D both for the ion ITB and the electron ITB plasmas and qualitatively agreed with the tendency of the change in the thermal diffusivity obtained from the power balance analysis
    corecore