77 research outputs found

    a feature tracking model simulates the motion direction bias induced by phase congruency

    Get PDF
    Here we report a new motion illusion where the prevailing motion direction is strongly influenced by the relative phase of the harmonic components of the stimulus. The basic stimulus is the sum of three sinusoidal contrast-reversing gratings: the first, the third, and the fifth harmonic of two square wave gratings that drift in opposite direction. The phase of one of the fifth components was kept constant at 180 deg, whereas the phase of the other fifth harmonic was varied over the range 0Y150 deg. For each phase value of the fifth harmonic, the motion was strongly biased toward its direction, corresponding to the direction with stronger phase congruency between the three harmonics. The strength of the prevailing motion was assessed by measuring motion direction discrimination thresholds, by varying the contrast of the third and the fifth harmonics plaid pattern. Results show that the contrast of high harmonics had to be increased by more than a factor of 10, to achieve a balance of motion for phase differences greater than 60 deg between the 2 fifth harmonics. We also measured the dependence on the absolute phase of harmonic components and found that it is not an important parameter, excluding the possibility that local luminance cues could be mediating the effect. A feature-tracking model based on previous work is proposed to simulate the data. The model computes local energy function from a pair of space-time separable front stage filters and applies a battery of directional second stage mechanisms. It is able to simulate quantitatively the phase congruency dependence illusion and the insensitivity to overall phase. Other energy models based on directional filters fail to simulate the phase congruency dependency effect

    Large receptive fields for optic flow detection in humans

    Get PDF
    AbstractWe used a psychophysical summation technique to study the properties of detectors tuned to radial, circular and translational motion, and to determine the spatial extent of their receptive fields. Signal-to-noise motion thresholds were measured for patterns curtailed spatially in various ways. Sensitivity for radial, circular and translational motion increased with stimulus area at a rate predicted by an ideal integrator. When sectors of noise were added to the stimulus, sensitivity decreased at a rate consistent with an ideal integrator. Summation was tested for large annular stimuli, and shown to hold up to 70° in some cases, suggesting very large receptive fields for this type of motion (consistent with the physiology of neurones in the dorsal region of the medial superior temporal area (MSTd)). This is a far greater area than observed for summation of contrast sensitivity to gratings (Anderson SJ and Burr DC, Vis Res 1987;29:621–635, and to this type of stimuli (Morrone MC, Burr DC and Vaina LM, Nature 1995;376:507–509, consistent with the suggestion that the two techniques examine different levels of motion analysis

    Saccadic compression can improve detection of Glass patterns

    Get PDF
    Abstract Around the time of saccadic eye movements, briefly presented stimuli are seen to be displaced from their real positions. The direction of the displacement is always towards the saccadic target, resulting in a compression of visual space (Nature 386 (1997) 598). To examine whether the compression may be used by the visual system to aid performance, we measured sensitivity for detecting horizontal and vertical Glass patterns around the time of saccades. Sensitivity to widely spaced horizontal Glass patterns improved slightly during the period just prior to making a horizontal saccade, while sensitivity to vertical patterns was impaired by the saccade. The results provide further evidence for compression in the direction of the saccade at saccadic onset, and show that it does not only affect the apparent position of visual stimuli, but can also improve performance on a visual task.

    Long Covid: where we stand and challenges ahead

    Get PDF
    Post-acute sequelae of SARS-CoV-2 (PASC), also known as Post-Covid Syndrome, and colloquially as Long Covid, has been defined as a constellation of signs and symptoms which persist for weeks or months after the initial SARS-CoV-2 infection. PASC affects a wide range of diverse organs and systems, with manifestations involving lungs, brain, the cardiovascular system and other organs such as kidney and the neuromuscular system. The pathogenesis of PASC is complex and multifactorial. Evidence suggests that seeding and persistence of SARS-CoV-2 in different organs, reactivation, and response to unrelated viruses such as EBV, autoimmunity, and uncontrolled inflammation are major drivers of PASC. The relative importance of pathogenetic pathways may differ in different tissue and organ contexts. Evidence suggests that vaccination, in addition to protecting against disease, reduces PASC after breakthrough infection although its actual impact remains to be defined. PASC represents a formidable challenge for health care systems and dissecting pathogenetic mechanisms may pave the way to targeted preventive and therapeutic approaches

    Inversion of perceived direction of motion caused by spatial undersampling in two children with periventricular leukomalacia

    Get PDF
    We report here two cases of two young diplegic patients with cystic periventricular leukomalacia who systematically, and with high sensitivity, perceive translational motion of a random-dot display in the opposite direction. The apparent inversion was specific for translation motion: Rotation and expansion motion were perceived correctly, with normal sensitivity. It was also specific for random-dot patterns, not occurring with gratings. For the one patient that we were able to test extensively, contrast sensitivity for static stimuli was normal, but was very low for direction discrimination at high spatial frequencies and all temporal frequencies. His optokinetic nystagmus movements were normal but he was unable to track a single translating target, indicating a perceptual origin of the tracking deficit. The severe deficit for motion perception was also evident in the seminatural situation of a driving simulation video game. The perceptual deficit for translational motion was reinforced by functional magnetic resonance imaging studies. Translational motion elicited no response in the MT complex, although it did produce a strong response in many visual areas when contrasted with blank stimuli. However, radial and rotational motion produced a normal pattern of activation in a subregion of the MT complex. These data reinforce the existent evidence for independent cortical processing for translational, and circular or radial flow motion, and further suggest that the two systems have different vulnerability and plasticity to prenatal damage. They also highlight the complexity of visual motion perception, and how the delicate balance of neural activity can lead to paradoxical effects such as consistent misperception of the direction of motion. We advance a possible explanation of a reduced spatial sampling of the motion stimuli and report a simple model that simulates well the experimental results

    Multicentric Atrial Strain COmparison between Two Different Modalities: MASCOT HIT Study

    Get PDF
    Two methods are currently available for left atrial (LA) strain measurement by speckle tracking echocardiography, with two different reference timings for starting the analysis: QRS (QRS-LASr) and P wave (P-LASr). The aim of MASCOT HIT study was to define which of the two was more reproducible, more feasible, and less time consuming. In 26 expert centers, LA strain was analyzed by two different echocardiographers (young vs senior) in a blinded fashion. The study population included: healthy subjects, patients with arterial hypertension or aortic stenosis (LA pressure overload, group 2) and patients with mitral regurgitation or heart failure (LA volume–pressure overload, group 3). Difference between the inter-correlation coefficient (ICC) by the two echocardiographers using the two techniques, feasibility and analysis time of both methods were analyzed. A total of 938 subjects were included: 309 controls, 333 patients in group 2, and 296 patients in group 3. The ICC was comparable between QRS-LASr (0.93) and P-LASr (0.90). The young echocardiographers calculated QRS-LASr in 90% of cases, the expert ones in 95%. The feasibility of P-LASr was 85% by young echocardiographers and 88% by senior ones. QRS-LASr young median time was 110 s (interquartile range, IR, 78-149) vs senior 110 s (IR 78-155); for P-LASr, 120 s (IR 80-165) and 120 s (IR 90-161), respectively. LA strain was feasible in the majority of patients with similar reproducibility for both methods. QRS complex guaranteed a slightly higher feasibility and a lower time wasting compared to the use of P wave as the reference

    Spatial maps for time and motion

    No full text
    In this article, we review recent research studying the mechanisms for transforming coordinate systems to encode space, time and motion. A range of studies using functional imaging and psychophysical techniques reveals mechanisms in the human brain for encoding information in external rather than retinal coordinates. This reinforces the idea of a tight relationship between space and time, in the parietal cortex of primates

    A feature-tracking model simulates the motion direction bias induced by phase congruency

    No full text
    corecore