38 research outputs found

    Realising the European network of biodosimetry: RENEB-status quo

    Get PDF
    Creating a sustainable network in biological and retrospective dosimetry that involves a large number of experienced laboratories throughout the European Union (EU) will significantly improve the accident and emergency response capabilities in case of a large-scale radiological emergency. A well-organised cooperative action involving EU laboratories will offer the best chance for fast and trustworthy dose assessments that are urgently needed in an emergency situation. To this end, the EC supports the establishment of a European network in biological dosimetry (RENEB). The RENEB project started in January 2012 involving cooperation of 23 organisations from 16 European countries. The purpose of RENEB is to increase the biodosimetry capacities in case of large-scale radiological emergency scenarios. The progress of the project since its inception is presented, comprising the consolidation process of the network with its operational platform, intercomparison exercises, training activities, proceedings in quality assurance and horizon scanning for new methods and partners. Additionally, the benefit of the network for the radiation research community as a whole is addressed

    Dedicated to

    No full text
    et de nationalité française acceptée sur proposition du jury: Prof. D. Thalmann, directeur de thès

    A new cytogenetic biodosimetry image repository for the dicentric assay

    No full text
    The BioDoseNet was founded by the World Health Organization as a global network of biodosimetry laboratories for building biodosimetry laboratory capacities in countries. The newly established BioDoseNet image repository is a databank of ~25 000 electronically captured images of metaphases from the dicentric assay, which have been previously analysed by international experts. The detailed scoring results and dose estimations have, in most cases, already been published. The compilation of these images into one image repository provides a valuable tool for training and research purposes in biological dosimetry. No special software is needed to view and score the image galleries. For those new to the dicentric assay, the BioDoseNet Image Repository provides an introduction to and training for the dicentric assay. It is an excellent instrument for intra-laboratory training purposes or inter-comparisons between laboratories, as recommended by the International Organization for Standardisation standards. In the event of a radiation accident, the repository can also increase the surge capacity and reduce the turnaround time for dose estimations. Finally, it provides a mechanism for the discussion of scoring discrepancies in difficult cases. © The Author 2016

    The first gamma-H2AX biodosimetry intercomparison exercise of the developing European biodosimetry network RENEB

    No full text
    In the event of a mass casualty radiation incident, the gamma-H2AX foci assay could be a useful tool to estimate radiation doses received by individuals. The rapid processing time of blood samples of just a few hours and the potential for batch processing, enabling high throughput, make the assay ideal for early triage categorisation to separate the 'worried well' from the low and critically exposed by quantifying radiation-induced foci in peripheral blood lymphocytes. Within the RENEB framework, 8 European laboratories have taken part in the first European gamma-H2AX biodosimetry exercise, which consisted of a telescoring comparison of 200 circulated foci images taken from 8 samples, and a comparison of 10 fresh blood lymphocyte samples that were shipped overnight to participating labs 4 or 24 h post-exposure. Despite large variations between laboratories in the dose-response relationship for foci induction, the obtained results indicate that the network should be able to use the gamma-H2AX assay for rapidly identifying the most severely exposed individuals within a cohort who could then be prioritised for accurate chromosome dosimetry

    A new cytogenetic biodosimetry image repository for the dicentric assay

    No full text
    The BioDoseNet was founded by the World Health Organization as a global network of biodosimetry laboratories for building biodosimetry laboratory capacities in countries. The newly established BioDoseNet image repository is a databank of ~25 000 electronically captured images of metaphases from the dicentric assay, which have been previously analysed by international experts. The detailed scoring results and dose estimations have, in most cases, already been published. The compilation of these images into one image repository provides a valuable tool for training and research purposes in biological dosimetry. No special software is needed to view and score the image galleries. For those new to the dicentric assay, the BioDoseNet Image Repository provides an introduction to and training for the dicentric assay. It is an excellent instrument for intra-laboratory training purposes or inter-comparisons between laboratories, as recommended by the International Organization for Standardisation standards. In the event of a radiation accident, the repository can also increase the surge capacity and reduce the turnaround time for dose estimations. Finally, it provides a mechanism for the discussion of scoring discrepancies in difficult cases

    Randomised comparison of coronary stenting with and without balloon predilatation in selected patients

    No full text
    BACKGROUND—The SWIBAP (stent without balloon predilatation) prospective randomised trial was designed to compare direct coronary stenting with stenting preceded by lesion predilatation with an angioplasty balloon.
OBJECTIVE—To determine the feasibility and safety of direct stenting in non-complex coronary lesions in a prospective study.
PATIENTS AND DESIGN—All patients < 76 years of age scheduled to undergo angioplasty of a non-complex, non-calcified lesion in a coronary artery of > 3.0 mm, who granted their informed consent, were randomised into the trial. In group I, the stent was placed without balloon predilatation, while in group II stent implantation was preceded by balloon predilatation. The primary end point was the angiographic result according to procedure assigned by randomisation. An intravascular ultrasound substudy was performed in 60( )patients.
RESULTS—Stent implantation was successful without predilatation in 192 of the 197 group I patients (97.5%), and with predilatation in 197 of the 199 group II patients (99%) (NS). No in-hospital stent thrombosis or death occurred. Overall procedural times, fluoroscopy times, and volumes of contrast agent given (mean (SD)) in group I v group II were 23.50 (13.54) min v 27.96 (15.23) min (p = 0.002), 6.04 (4.13) min v 6.67 (3.65) min (NS), and 135 (65) ml v 157 (62) ml (p < 0.001), respectively. No major adverse cardiovascular events had occurred by 30( )days.
CONCLUSIONS—The feasibility and safety of direct stenting of selected and non-complex coronary lesions is confirmed. This technique was as successful as the conventional approach and was associated with a minor reduction in fluoroscopic exposure and procedure time and the administration of less contrast agent.


Keywords: coronary artery angioplasty; stent; coronary artery ultrasoun

    Web based scoring is useful for validation and harmonisation of scoring criteria within RENEB

    No full text
    International audiencePurpose To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners. Materials and methods Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies. Results The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes. Conclusions Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network. © 2016 The Author(s). Published by Informa UK Limited, trading as Taylor and Francis Group
    corecore