58 research outputs found

    Analytical solutions for wall slip effects on magnetohydrodynamic oscillatory rotating plate and channel flows in porous media using a fractional burgers viscoelastic model

    Get PDF
    A theoretical analysis of magnetohydrodynamic (MHD) incompressible flows of Burger's fluid through a porous medium in a rotating frame of reference is presented. The constitutive model of a Burger's fluid is used based on a fractional calculus formulation. Hydrodynamic slip at the wall (plate) is incorporated and a fractional generalized Darcy model deployed to simulate porous medium drag force effects. Three different cases are considered- namely, flow induced by a general periodic oscillation at a rigid plate, periodic flow in a parallel plate channel and finally Poiseuille flow. In all cases the plate (s) boundary (ies) are electrically-non-conducting and small magnetic Reynolds is assumed, negating magnetic induction effects. The well-posed boundary value problems associated with each case are solved via Fourier transforms. Comparisons are made between the results derived with and without slip conditions. 4 special cases are retrieved from the general fractional Burgers model, viz Newtonian fluid, general Maxwell viscoelastic fluid, generalized Oldroyd-B fluid and the conventional Burger’s viscoelastic model. Extensive interpretation of graphical plots is included. We study explicitly the influence on wall slip on primary and secondary velocity evolution. The model is relevant to MHD rotating energy generators employing rheological working fluids

    Highly-parallelized simulation of a pixelated LArTPC on a GPU

    Get PDF
    The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on 10^3 pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype

    Acesso aos serviços de saúde: uma abordagem de geografia em saúde pública Access to health services: a geographical approach to public health

    Get PDF
    O acesso da população aos serviços de saúde é um pré-requisito de fundamental importância para uma eficiente assistência à saúde. A localização geográfica dos serviços é um dos fatores que interferem nessa acessibilidade. Pretendeu-se estudar a localização dos serviços de saúde. A proposta básica foi a de apresentação de uma metodologia considerando-se as relações de variáveis geográficas, demográficas e sociais. Enfatizou-se, no processo, a participação da comunidade. Efetuou-se o estudo da adequação dessa metodologia às características da região de Santo Amaro, Município de São Paulo, Brasil. A contribuição dada pela abordagem geográfica abre ampla perspectiva quanto ao estabelecimento de novas linhas de estudo, planejamento e gestão, advindas do intercâmbio entre a Geografia Humana e a Saúde Pública, numa área que se sugere denominar Geografia em Saúde Pública.<br>The access of the population to the health services is a requirement of basic importance for the efficiency of health assistance. The geographical localization of the services is one of the factors that interfere with this accessibility. It is intended to make a contribution to the study of the localization of health services. The basic proposal introduces a method which takes into account the relationships between geographical, demographical and social variables. Emphasis is placed on community participation in the process. The study of the adequacy of this method was undertaken under the regional characteristics of Santo Amaro, a suburb of the city of S. Paulo, Brazil. The contribution furnished by the geographical approach in this work opens up a broad perspective for the setting up of new lines of research, planning and administration resulting from the interation between human geography and public health within the common field for which it is suggested Geography of Public Health

    Transcatheter Aortic Heart Valves Histological Analysis Providing Insight to Leaflet Thickening and Structural Valve Degeneration

    No full text
    OBJECTIVES This study investigated processes causing leaflet thickening and structural valve degeneration (SVD).BACKGROUND Although transcatheter aortic valve replacement (TAVR) has changed the treatment of aortic stenosis, concerns remain regarding SVD, potentially related to valve thrombosis and thickening, based on studies using computed tomography (CT). Detailed histological analyses are provided to help attain insights into these processes.METHODS Explanted transcatheter heart valves (THVs) were evaluated for thrombosis, fibrosis, and calcification for quantification of leaflet thickness. Immunohistochemical and microscopy approaches were used to investigate SVD-associated mechanisms.RESULTS THVs (n=23) were obtained from 22 patients (median 81 years of age; 50% male) from 0 to 2,583 days post TAVR. Maximal leaflet thickness increased relative to implant duration (p = 0.427; p = 0.027). THVs explanted after >2 years were thicker than those explanted after <2 years (p = 0.007). All THVs had adherent thrombus on both aortic and ventricular sides, which beyond 60 days was seen in combination with fibrosis and beyond 4 years had calcification. Early thrombus formation (<60 days) occurred despite rapid endothetialization with an abnormal hyperplastic phenotype. Fibrosis was observed in 6 patients on both the aortic and the ventricular THV surfaces, remodeled over time, and was associated with matrix metalloproteinase-1 expression. Five THVs showed overt calcification associated with adherent thrombus and fibrosis.CONCLUSIONS There is a time-dependent degeneration of THVs consisting of thrombus formation, endothelial hyperplasia, fibrosis, tissue remodeling, proteinase expression, and calcification. Future investigation is needed to further understand these mechanisms contributing to leaflet thickening and SVD. (C) 2019 by the American College of Cardiology Foundation.Cardiolog
    corecore