188 research outputs found

    A five-year survey for plastic surgery malpractice claims in Rome, Italy

    Get PDF
    (1) Introduction: Medical malpractice claims against both health institutions and physicians are a crucial topic in Italy, as well as in other countries, particularly regarding civil proceedings. Our study reports an analysis of all of the malpractice judgments concerning plastic surgery decided in the Civil Court of Rome between 2012 and 2016. (2) Methods: the database of the Observatory Project on Medical Responsibility (ORMe) was analyzed, which collects all of the judgments of the Civil Court of Rome, that is, the first instance district court. Therefore, neither the jurisprudence of the second level court nor that of the Supreme Court was taken into account. (3) Results: 144 judgments concerning plastic surgery were delivered in the five-year period of 2012–2016 (corresponding to 10.6% of total professional liability verdicts of the Civil Court of Rome in the same period). In 101/144 cases (70.14%), the claim was accepted. A total of €4,727,579.00 was paid in compensation for plastic surgery malpractice claims, with a range from a minimum amount of €1555.96 to a maximum amount of €1,425,155.00 and an average compensation of €46,807.71 per claim that was significantly lower compared to other surgical disciplines. (4) Conclusions: Our data confirm that the analyzed branch has a high litigation rate, with a prevalence of convictions for cosmetic procedures over reconstructive ones, both for malpractice and for violation of the informed consent. Plastic surgery is also confirmed among those branches in which the professionals are more frequently sued compared to health institutions

    A Novel Approach for an Integrated Straw tube-Microstrip Detector

    Full text link
    We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell ®^{\circledR} lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.Comment: Accepted by Transactions on Nuclear Science (2005). 11 pages, 9 figures, uses lnfprep.st

    Two- and Three-Dimensional Reconstruction and Analysis of the Straw Tubes Tomography in the Btev Experiment

    Full text link
    A check of the eccentricity of the aluminised kapton straw tubes used in the BTeV experiment is accomplished using X-ray tomography of the section of tubes modules. 2 and 3-dimensional images of the single tubes and of the modules are reconstructed and analysed. Preliminary results show that a precision better than 40 μ\mum can be reached on the measurement of the straw radii.Comment: Presented by F.Massa at ICATPP05, Villa Olmo (Como) Italy, November 2005. 4 pages, 8 figures, uses lnfprep.st

    Micrometric Position Monitoring Using Fiber Bragg Grating Sensors in Silicon Detectors

    Full text link
    We show R&D results including long term stability, resolution, radiation hardness and characterization of Fiber Grating sensors used to monitor structure deformation, repositioning and surveying of silicon detector in High Energy Physics.Comment: Presented by S.Bianco at ICATPP05, Villa Olmo (Como) Italy, November 2005. 5 pages, 6 figures, uses lnfprep.st

    Primary squamous cell carcinoma of major salivary gland: “Sapienza Head and Neck Unit” clinical recommendations

    Get PDF
    Primary squamous cell carcinoma of salivary gland (SCG) is an extremely rare type of malignant salivary gland tumor, which in turn results in scarcity of data available regarding both its treatment and associated genetic alterations. A retrospective analysis of 12 patients with primary SCG was conducted, along with analysis of the association between treatment, clinical/pathological characteristics, and outcomes. Most patients (8) were staged IVa, with the majority of them (10) having G3 fast growing cancer. Local and systemic recurrence were reported in only three out of nine parotid cases (0 out of 2 submandibular SCGs). In two out of eight patients local relapse occurred after integrated treatment, while recurrence occurred in two out of three patients undergoing exclusive surgery. Five patients eventually died. Treatment of resectable disease must be aggressive and multimodal, with achievement of loco-regional control in order to reduce rate of recurrence and improve outcomes. Metastatic disease would require a therapeutic strategy tailored to the molecular profile in order to improve the currently disappointing results

    Uncertainty on radiation doses estimated by biological and retrospective physical methods

    Get PDF
    Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the ‘EURADOS Working Group 10— Retrospective dosimetry’ members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte Carlo techniques to support characterisation of uncertainties. It is concluded that sufficient techniques are available and in use by most laboratories for acute, whole body exposures to highly penetrating radiation, but further work will be required to ensure that statistical analysis is always wholly sufficient for the more complex exposure scenarios

    Handling the Background in IXPE Polarimetric Data

    Get PDF
    Imaging X-ray Polarimetry Explorer (IXPE) is a Small Explorer mission by NASA and Agenzia Spaziale Italiana, launched on 2021 December 9, dedicated to investigating X-ray polarimetry allowing angular-, time-, and energy-resolved observations in the 2-8 keV energy band. IXPE is in the science observation phase since 2022 January; it is comprised of three identical telescopes with grazing-incidence mirrors, each one having in the focal plane a gas pixel detector. In this paper, we present a possible guideline to obtain an optimal background selection in polarimetric analysis, and a rejection strategy to remove instrumental background. This work is based on the analysis of IXPE observations, aiming to improve as much as possible the polarimetric sensitivity. In particular, the developed strategies have been applied as a case study to the IXPE observation of the 4U 0142+61 magnetar
    corecore