274 research outputs found
Ureteral endometriosis: clinical and radiological follow-up after laparoscopic ureterocystoneostomy
n/
Treatment of atrial fibrillation with a dual defibrillator in heart failure patients (TRADE HF): protocol for a randomized clinical trial.
Background: Heart failure(HF) and atrial fibrillation(AF) frequently coexist in the same patient and are associated with increased mortality and frequent hospitalizations. As the concomitance of AF and HF is often associated with a poor prognosis, the prompt treatment of AF in HF patients may significantly improve outcome.Methods/design: Recent implantable cardiac resynchronization (CRT) devices allow electrical therapies to treat AF automatically. TRADE-HF (trial registration: NCT00345592; http://www.clinicaltrials.gov) is a prospective, randomized, double arm study aimed at demonstrating the efficacy of an automatic, device-based therapy for treatment of atrial tachycardia and fibrillation(AT/AF) in patients indicated for CRT. The study compares automatic electrical therapy to a traditional more usual treatment of AT/AF: the goal is to demonstrate a reduction in a combined endpoint of unplanned hospitalizations for cardiac reasons, death from cardiovascular causes or permanent AF when using automatic atrial therapy as compared to the traditional approach involving hospitalization for symptoms and in-hospital treatment of AT/AF.Discussion: CRT pacemaker with the additional ability to convert AF as well as ventricular arrhythmias may play a simultaneous role in rhythm control and HF treatment. The value of the systematic implantation of CRT ICDs with the capacity to deliver atrial therapy in HF patients at risk of AF has not yet been explored. The TRADE-HF study will assess in CRT patients whether a strategy based on automatic management of atrial arrhythmias might be a valuable option to reduce the number of hospital admission and to reduce the progression the arrhythmia to a permanent for
Integration of a Smartphone HF-Dedicated App in the Remote Monitoring of Heart Failure Patients with Cardiac Implantable Electronic Devices: Patient Access, Acceptance, and Adherence to Use
(200 w) Introduction. Remote monitoring (RM) of cardiac implantable electronic device (CIED) diagnostics helps to identify patients potentially at risk of worsening heart failure (HF). Additionally, knowledge of patient HF-related symptoms is crucial for decision making. Patient smartphone applications may represent an ideal option to remotely collect this information. Purpose. To assess real-world HF patient access, acceptance, and adherence to use of an HF-dedicated smartphone application (HF app). Methods. In this study, 10 Italian hospitals administered a survey on smartphone/app use to HF patients with CIED. The subgroup who accepted it downloaded the HF app. Mean 1-year adherence of the HF app use was evaluated. Results. A total of 495 patients (67 ± 13 years, 79% males, 26% NYHA III–IV) completed the survey, of which 84% had access to smartphones and 85% were willing to use the HF app. In total, 311/495 (63%) downloaded the HF app. Patients who downloaded the HF app were younger and had higher school qualification. Patients who were ≥60 years old had higher mean 1-year adherence (54.1%) than their younger counterparts (42.7%; p < 0.001). Hospitals with RM-dedicated staff had higher mean 1-year patient adherence (64.0% vs. 33.5%; p < 0.001). Adherence to HF app decreased from 63.3% (weeks_1–13) to 42.2% (weeks_40–52, p < 0.001). Conclusions. High access and acceptance of smartphones/apps by HF patients with CIED allow HF app use for RM of patient signs/symptoms. Younger patients with higher school qualifications are more likely to accept HF app; however, older patients have higher long-term adherence
Continuous pulse advances in the negative ion source NIO1
Consorzio RFX and INFN-LNL have designed, built and operated the compact
radiofrequency negative ion source NIO1 (Negative Ion Optimization phase 1)
with the aim of studying the production and acceleration of H- ions. In
particular, NIO1 was designed to keep plasma generation and beam extraction
continuously active for several hours. Since 2020 the production of negative
ions at the plasma grid (the first grid of the acceleration system) has been
enhanced by a Cs layer, deposited though active Cs evaporation in the source
volume. For the negative ion sources applied to fusion neutral beam injectors,
it is essential to keep the beam current and the fraction of co-extracted
electrons stable for at least 1 h, against the consequences of Cs sputtering
and redistribution operated by the plasma. The paper presents the latest
results of the NIO1 source, in terms of caesiation process and beam
performances during continuous (6{\div}7 h) plasma pulses. Due to the small
dimensions of the NIO1 source (20 x (diam.)10 cm), the Cs density in the volume
is high (10^15 \div 10^16 m^-3) and dominated by plasma-wall interaction. The
maximum beam current density and minimum fraction of co-extracted electrons
were respectively about 30 A/m^2 and 2. Similarly to what done in other
negative ion sources, the plasma grid temperature in NIO1 was raised for the
first time, up to 80 {\deg}C, although this led to a minimal improvement of the
beam current and to an increase of the co-extracted electron current.Comment: 11 pages, 7 figures. Contributed paper for the 8th International
symposium on Negative Ions, Beams and Sources - NIBS'22. Revision 1 of the
preprint under evaluation at Journal of Instrumentation (JINST
Effectiveness of cardiac resynchronization therapy in heart failure patients with valvular heart disease: comparison with patients affected by ischaemic heart disease or dilated cardiomyopathy. The InSync/InSync ICD Italian Registry
AimsTo analyse the effectiveness of cardiac resynchronization therapy (CRT) in patients with valvular heart disease (a subset not specifically investigated in randomized controlled trials) in comparison with ischaemic heart disease or dilated cardiomyopathy patients.Methods and resultsPatients enrolled in a national registry were evaluated during a median follow-up of 16 months after CRT implant. Patients with valvular heart disease treated with CRT (n = 108) in comparison with ischaemic heart disease (n = 737) and dilated cardiomyopathy (n = 635) patients presented: (i) a higher prevalence of chronic atrial fibrillation, with atrioventricular node ablation performed in around half of the cases; (ii) a similar clinical and echocardiographic profile at baseline; (iii) a similar improvement of LVEF and a similar reduction in ventricular volumes at 6-12 months; (iv) a favourable clinical response at 12 months with an improvement of the clinical composite score similar to that occurring in patients with dilated cardiomyopathy and more pronounced than that observed in patients with ischaemic heart disease; (v) a long-term outcome, in term of freedom from death or heart transplantation, similar to patients affected by ischaemic heart disease and basically more severe than that of patients affected by dilated cardiomyopathy.ConclusionIn 'real world' clinical practice, CRT appears to be effective also in patients with valvular heart disease. However, in this group of patients the outcome after CRT does not precisely overlap any of the two other groups of patients, for which much more data are currently available
CD8+ T-Cells Expressing Interferon Gamma or Perforin Play Antagonistic Roles in Heart Injury in Experimental Trypanosoma Cruzi-Elicited Cardiomyopathy
In Chagas disease, CD8+ T-cells are critical for the control of Trypanosoma cruzi during acute infection. Conversely, CD8+ T-cell accumulation in the myocardium during chronic infection may cause tissue injury leading to chronic chagasic cardiomyopathy (CCC). Here we explored the role of CD8+ T-cells in T. cruzi-elicited heart injury in C57BL/6 mice infected with the Colombian strain. Cardiomyocyte lesion evaluated by creatine kinase-MB isoenzyme activity levels in the serum and electrical abnormalities revealed by electrocardiogram were not associated with the intensity of heart parasitism and myocarditis in the chronic infection. Further, there was no association between heart injury and systemic anti-T. cruzi CD8+ T-cell capacity to produce interferon-gamma (IFNγ) and to perform specific cytotoxicity. Heart injury, however, paralleled accumulation of anti-T. cruzi cells in the cardiac tissue. In T. cruzi infection, most of the CD8+ T-cells segregated into IFNγ+ perforin (Pfn)neg or IFNγnegPfn+ cell populations. Colonization of the cardiac tissue by anti-T. cruzi CD8+Pfn+ cells paralleled the worsening of CCC. The adoptive cell transfer to T. cruzi-infected cd8−/− recipients showed that the CD8+ cells from infected ifnγ−/−pfn+/+ donors migrate towards the cardiac tissue to a greater extent and caused a more severe cardiomyocyte lesion than CD8+ cells from ifnγ+/+pfn−/− donors. Moreover, the reconstitution of naïve cd8−/− mice with CD8+ cells from naïve ifnγ+/+pfn−/− donors ameliorated T. cruzi-elicited heart injury paralleled IFNγ+ cells accumulation, whereas reconstitution with CD8+ cells from naïve ifnγ−/−pfn+/+ donors led to an aggravation of the cardiomyocyte lesion, which was associated with the accumulation of Pfn+ cells in the cardiac tissue. Our data support a possible antagonist effect of CD8+Pfn+ and CD8+IFNγ+ cells during CCC. CD8+IFNγ+ cells may exert a beneficial role, whereas CD8+Pfn+ may play a detrimental role in T. cruzi-elicited heart injury
A Role for the Chemokine RANTES in Regulating CD8 T Cell Responses during Chronic Viral Infection
RANTES (CCL5) is a chemokine expressed by many hematopoietic and non-hematopoietic cell types that plays an important role in homing and migration of effector and memory T cells during acute infections. The RANTES receptor, CCR5, is a major target of anti-HIV drugs based on blocking viral entry. However, defects in RANTES or RANTES receptors including CCR5 can compromise immunity to acute infections in animal models and lead to more severe disease in humans infected with west Nile virus (WNV). In contrast, the role of the RANTES pathway in regulating T cell responses and immunity during chronic infection remains unclear. In this study, we demonstrate a crucial role for RANTES in the control of systemic chronic LCMV infection. In RANTES−/− mice, virus-specific CD8 T cells had poor cytokine production. These RANTES−/− CD8 T cells also expressed higher amounts of inhibitory receptors consistent with more severe exhaustion. Moreover, the cytotoxic ability of CD8 T cells from RANTES−/− mice was reduced. Consequently, viral load was higher in the absence of RANTES. The dysfunction of T cells in the absence of RANTES was as severe as CD8 T cell responses generated in the absence of CD4 T cell help. Our results demonstrate an important role for RANTES in sustaining CD8 T cell responses during a systemic chronic viral infection
- …