6,612 research outputs found

    On weakly (tilderho,tildeD)(tilde{rho}, tilde{D})-separable polynomials in skew polynomial rings (Algebras, logics, languages and related areas)

    Get PDF
    Separable polynomials in skew polynomial rings were studied extensively by Y. Miyashita, T. Nagahara, S. Ikehata, and G. S eto. In particular, Ikehata gave the characteri ation of (overline{rho}, overline{D})-separable polynomials in skew polynomial rings. In this article, we shall introduce the notion of weakly (overline{rho}, tilde{D})-separable polynomials in skew polynomial rings, and we shall give a characteri ation of the (overline{p}, overline{D})-separability and that of the weak (overline{rho}, overline{D})-separability

    Evaluation of the effects of gastrectomy on the development of metabolic bone disease

    Get PDF
    13301甲第4588号博士(医学)金沢大学博士論文要旨Abstract 以下に掲載:Journal of Surgical Research 212 pp.22811-22824 2017. Scott LeMaire. 共著者:Higashi Y, Fujimura T, Oyama K, Kinoshita J, Miyashita T, Tajima H, Fushida S, Ohta T

    Energy and time resolution for a LYSO matrix prototype of the Mu2e experiment

    Full text link
    We have measured the performances of a LYSO crystal matrix prototype tested with electron and photon beams in the energy range 60-450 MeV. This study has been carried out to determine the achievable energy and time resolutions for the calorimeter of the Mu2e experiment.Comment: 2 pages, 3 figures, 13th Pisa Meeting on Advanced Detector

    Quality Assurance on a custom SiPMs array for the Mu2e experiment

    Full text link
    The Mu2e experiment at Fermilab will search for the coherent μe\mu \to e conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.Comment: 4 pages, 10 figures, conference proceeding for NSS-MIC 201

    Design, status and perspective of the Mu2e crystal calorimeter

    Full text link
    The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less μe\mu \to e coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about 2.510172.5\cdot 10^{-17} that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform μ\mu/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R&\&D results.Comment: 4 pages, conference proceeding for a presentation held at TIPP'2017. To be published on Springer Proceedings in Physic

    The Mu2e undoped CsI crystal calorimeter

    Full text link
    The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.Comment: 6 pages, 8 figures, proceedings of the "Calorimetry for the high energy frontier (CHEF17)" conference, 2-6 October 2017, Lyon, Franc

    Experimental Signature of Medium Modifications for rho and omega Mesons in the 12 GeV p + A Reactions

    Full text link
    The invariant mass spectra of e+e- pairs produced in 12-GeV proton-induced nuclear reactions are measured at the KEK Proton-Synchrotron. On the low-mass side of the omega meson peak, a significant enhancement over the known hadronic sources has been observed. The mass spectra, including the excess, are well reproduced by a model that takes into account the density dependence of the vector meson mass modification, as theoretically predicted.Comment: 4 pages, 3 figures, Version accepted for Physical Review Lette

    Improved Limits on B0B^{0} decays to invisible (+γ)(+\gamma) final states

    Get PDF
    We establish improved upper limits on branching fractions for B0 decays to final States 10 where the decay products are purely invisible (i.e., no observable final state particles) and for final states where the only visible product is a photon. Within the Standard Model, these decays have branching fractions that are below the current experimental sensitivity, but various models of physics beyond the Standard Model predict significant contributions for these channels. Using 471 million BB pairs collected at the Y(4S) resonance by the BABAR experiment at the PEP-II e+e- storage ring at the SLAC National Accelerator Laboratory, we establish upper limits at the 90% confidence level of 2.4x10^-5 for the branching fraction of B0-->Invisible and 1.7x10^-5 for the branching fraction of B0-->Invisible+gammaComment: 8 pages, 3 postscript figures, submitted to Phys. Rev. D (Rapid Communications

    Soluble tau species, not neurofibrillary aggregates, disrupt neural system integration in a tau transgenic model

    Get PDF
    Neurofibrillary tangles are a feature of Alzheimer disease and other tauopathies, and while they are generally believed to be markers of neuronal pathology, there is little evidence evaluating whether tangles directly impact neuronal function. To investigate the response of cells in hippocampal circuits to complex behavioral stimuli, we used an environmental enrichment paradigm to induce expression of an immediate-early gene, Arc, in the rTg4510 mouse model of tauopathy. These mice reversibly overexpress P301L tau and exhibit substantial neurofibrillary tangle deposition, neuronal loss, and memory deficits. Employing fluorescent in situ hybridization to detect Arc mRNA, we found that rTg4510 mice have impaired hippocampal Arc expression both without stimulation and in response to environmental enrichment; this likely reflects the combination of functional impairments of existing neurons and loss of neurons. However, tangle-bearing cells were at least as likely as non-tangle-bearing neurons to exhibit Arc expression in response to enrichment. Transgene suppression with doxycycline for 6 weeks resulted in increased percentages of Arc-positive cells in rTg4510 brains compared to untreated transgenics, restoring enrichment-induced Arc mRNA levels to that of wild-type controls despite the continued presence of neurofibrillary pathology. We interpret these data to indicate that soluble tau contributes to impairment of hippocampal function, while tangles do not preclude neurons from responding in a functional circuit
    corecore