19 research outputs found
Routine use of ancillary investigations in staging diffuse large B-cell lymphoma improves the International Prognostic Index (IPI)
<p>Abstract</p> <p>Background</p> <p>The International Prognostic Index (IPI) is used to determine prognosis in diffuse large B-cell lymphoma (DLBCL). One of the determinants of IPI is the stage of disease with bone marrow involvement being classified as stage IV. For the IPI, involvement on bone marrow is traditionally defined on the basis of histology with ancillary investigations used only in difficult cases to aid histological diagnosis. This study aimed to determine the effect of the routine use of flow cytometry, immunohistochemistry and molecular studies in bone marrow staging upon the IPI.</p> <p>Results</p> <p>Bone marrow trephines of 156 histologically proven DLBCL cases at initial diagnosis were assessed on routine histology, and immunohistochemistry using two T-cell markers (CD45RO and CD3), two B-cell markers (CD20 and CD79a) and kappa and lambda light chains. Raw flow cytometry data on all samples were reanalysed and reinterpreted blindly. DNA extracted from archived paraffin-embedded trephine biopsy samples was used for immunoglobulin heavy chain and light chain gene rearrangement analysis. Using immunophenotyping (flow cytometry and immunohistochemistry), 30 (19.2%) cases were upstaged to stage IV. A further 8 (5.1%) cases were upstaged using molecular studies. A change in IPI was noted in 18 cases (11.5%) on immunophenotyping alone, and 22 (14.1%) cases on immunophenotyping and molecular testing. Comparison of two revised IPI models, 1) using immunophenotyping alone, and 2) using immunophenotyping with molecular studies, was performed with baseline IPI using a Cox regression model. It showed that the revised IPI model using immunophenotyping provides the best differentiation between the IPI categories.</p> <p>Conclusion</p> <p>Improved bone marrow staging using flow cytometry and immunohistochemistry improves the predictive value of the IPI in patients with DLBCL and should be performed routinely in all cases.</p
Diagnosis of acute myeloid leukemia according to the WHO classification in the Japan Adult Leukemia Study Group AML-97 protocol
We reviewed and categorized 638 of 809 patients who were registered in the Japan Adult Leukemia Study Group acute myeloid leukemia (AML)-97 protocol using morphological means. Patients with the M3 subtype were excluded from the study group. According to the WHO classification, 171 patients (26.8%) had AML with recurrent genetic abnormalities, 133 (20.8%) had AML with multilineage dysplasia (MLD), 331 (51.9%) had AML not otherwise categorized, and 3 (0.5%) had acute leukemia of ambiguous lineage. The platelet count was higher and the rate of myeloperoxidase (MPO)-positive blasts was lower in AML with MLD than in the other WHO categories. The outcome was significantly better in patients with high (â„50%) than with low (<50%) ratios of MPO-positive blasts (PÂ <Â 0.01). The 5-year survival rates for patients with favorable, intermediate, and adverse karyotypes were 63.4, 39.1, and 0.0%, respectively, and 35.5% for those with 11q23 abnormalities (PÂ <Â 0.0001). Overall survival (OS) did not significantly differ between nine patients with t(9;11) and 23 with other 11q23 abnormalities (PÂ =Â 0.22). Our results confirmed that the cytogenetic profile, MLD phenotype, and MPO-positivity of blasts are associated with survival in patients with AML, and showed that each category had the characteristics of the WHO classification such as incidence, clinical features, and OS
A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real-time quantitative PCR
Serial quantification of BCRâABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a
substantial variation in results reported by diff
Standardization of molecular monitoring of CML: results and recommendations from the European treatment and outcome study
Standardized monitoring of BCR::ABL1 mRNA levels is essential for the management of chronic myeloid leukemia (CML) patients. From 2016 to 2021 the European Treatment and Outcome Study for CML (EUTOS) explored the use of secondary, lyophilized cell-based BCR::ABL1 reference panels traceable to the World Health Organization primary reference material to standardize and validate local laboratory tests. Panels were used to assign and validate conversion factors (CFs) to the International Scale and assess the ability of laboratories to assess deep molecular response (DMR). The study also explored aspects of internal quality control. The percentage of EUTOS reference laboratories (n = 50) with CFs validated as optimal or satisfactory increased from 67.5% to 97.6% and 36.4% to 91.7% for ABL1 and GUSB, respectively, during the study period and 98% of laboratories were able to detect MR4.5 in most samples. Laboratories with unvalidated CFs had a higher coefficient of variation for BCR::ABL1(IS) and some laboratories had a limit of blank greater than zero which could affect the accurate reporting of DMR. Our study indicates that secondary reference panels can be used effectively to obtain and validate CFs in a manner equivalent to sample exchange and can also be used to monitor additional aspects of quality assurance.</p
A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real time quantitative PCR
Serial quantification of BCRâABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a substantial variation in results reported by different laboratories. To improve comparability, an internationally accepted plasmid certified reference material (CRM) was developed according to ISO Guide 34:2009. Fragments of BCRâABL1 (e14a2 mRNA fusion), BCR and GUSB transcripts were amplified and cloned into pUC18 to yield plasmid pIRMM0099. Six different linearised plasmid solutions were produced with the following copy number concentrations, assigned by digital PCR, and expanded uncertainties: 1.08±0.13 Ă 106, 1.08±0.11 Ă 105, 1.03±0.10 Ă 104, 1.02±0.09 Ă 103, 1.04±0.10 Ă 102 and 10.0±1.5 copies/?l. The certification of the material for the number of specific DNA fragments per plasmid, copy number concentration of the plasmid solutions and the assessment of inter-unit heterogeneity and stability were performed according to ISO Guide 35:2006. Two suitability studies performed by 63 BCRâABL1 testing laboratories demonstrated that this set of 6 plasmid CRMs can help to standardise a number of measured transcripts of e14a2 BCRâABL1 and three control genes (ABL1, BCR and GUSB). The set of six plasmid CRMs is distributed worldwide by the Institute for Reference Materials and Measurements (Belgium) and its authorised distributors (https://ec.europa.eu/jrc/en/reference-materials/catalogue/; CRM code ERM-AD623a-f)
Development and evaluation of a secondary reference panel for BCR-ABL1 quantitation on the International Scale
Molecular monitoring of chronic myeloid leukemia patients using robust BCR-ABL1 tests standardized to the International Scale (IS) is key to proper disease management, especially when treatment cessation is considered. Most laboratories currently utilize a time-consuming sample exchange process with reference laboratories for IS calibration. A World Health Organization (WHO) BCR-ABL1 reference panel was developed (MR1-MR4), but access to the material is limited. In this study, we describe the development of the first cell-based secondary reference panel thatâs traceable to and faithfully replicates the WHO panel, with an additional MR4.5 level. The secondary panel was calibrated to IS using digital PCR with ABL1, BCR, and GUSB as reference genes and evaluated by 44 laboratories worldwide. Interestingly, we found that >40% of BCR-ABL1 assays showed signs of inadequate optimization such as poor linearity and suboptimal PCR efficiency. Nonetheless, when optimized sample inputs were used, >60% demonstrated satisfactory IS accuracy, precision and/or MR4.5 sensitivity, and 58% obtained IS conversion factors from the secondary reference concordant with their current ones. Correlation analysis indicated no significant alterations in %BCR-ABL1 results caused by different assay configurations. More assays achieved good precision and/or sensitivity than IS accuracy, indicating the need for better IS calibration mechanisms