43 research outputs found

    The Outer Disks of Early-Type Galaxies. I. Surface-Brightness Profiles of Barred Galaxies

    Full text link
    We present a study of 66 barred, early-type (S0-Sb) disk galaxies, focused on the disk surface brightness profile outside the bar region and the nature of Freeman Type I and II profiles, their origins, and their possible relation to disk truncations. This paper discusses the data and their reduction, outlines our classification system, and presents RR-band profiles and classifications for all galaxies in the sample. The profiles are derived from a variety of different sources, including the Sloan Digital Sky Survey (Data Release 5). For about half of the galaxies, we have profiles derived from more than one telescope; this allows us to check the stability and repeatability of our profile extraction and classification. The vast majority of the profiles are reliable down to levels of mu_R ~ 27 mag arcsec^-2; in exceptional cases, we can trace profiles down to mu_R > 28. We can typically follow disk profiles out to at least 1.5 times the traditional optical radius R_25; for some galaxies, we find light extending to ~ 3 R_25. We classify the profiles into three main groups: Type I (single-exponential), Type II (down-bending), and Type III (up-bending). The frequencies of these types are approximately 27%, 42%, and 24%, respectively, plus another 6% which are combinations of Types II and III. We further classify Type II profiles by where the break falls in relation to the bar length, and in terms of the postulated mechanisms for breaks at large radii ("classical trunction" of star formation versus the influence of the Outer Lindblad Resonance of the bar). We also classify the Type III profiles by the probable morphology of the outer light (disk or spheroid). Illustrations are given for all cases. (Abridged)Comment: 41 pages, 26 PDF figures. To appear in the Astronomical Journal. Version with full-resolution figures available at http://www.mpe.mpg.de/~erwin/research

    Poplar GTL1 Is a Ca2+/Calmodulin-Binding Transcription Factor that Functions in Plant Water Use Efficiency and Drought Tolerance

    Get PDF
    Diminishing global fresh water availability has focused research to elucidate mechanisms of water use in poplar, an economically important species. A GT-2 family trihelix transcription factor that is a determinant of water use efficiency (WUE), PtaGTL1 (GT-2 like 1), was identified in Populus tremula × P. alba (clone 717-IB4). Like other GT-2 family members, PtaGTL1 contains both N- and C-terminal trihelix DNA binding domains. PtaGTL1 expression, driven by the Arabidopsis thaliana AtGTL1 promoter, suppressed the higher WUE and drought tolerance phenotypes of an Arabidopsis GTL1 loss-of-function mutation (gtl1-4). Genetic suppression of gtl1-4 was associated with increased stomatal density due to repression of Arabidopsis STOMATAL DENSITY AND DISTRIBUTION1 (AtSDD1), a negative regulator of stomatal development. Electrophoretic mobility shift assays (EMSA) indicated that a PtaGTL1 C-terminal DNA trihelix binding fragment (PtaGTL1-C) interacted with an AtSDD1 promoter fragment containing the GT3 box (GGTAAA), and this GT3 box was necessary for binding. PtaGTL1-C also interacted with a PtaSDD1 promoter fragment via the GT2 box (GGTAAT). PtaSDD1 encodes a protein with 60% primary sequence identity with AtSDD1. In vitro molecular interaction assays were used to determine that Ca2+-loaded calmodulin (CaM) binds to PtaGTL1-C, which was predicted to have a CaM-interaction domain in the first helix of the C-terminal trihelix DNA binding domain. These results indicate that, in Arabidopsis and poplar, GTL1 and SDD1 are fundamental components of stomatal lineage. In addition, PtaGTL1 is a Ca2+-CaM binding protein, which infers a mechanism by which environmental stimuli can induce Ca2+ signatures that would modulate stomatal development and regulate plant water use

    Applications and efficiencies of the first cat 63K DNA array

    Get PDF
    Correction, Volume: 8 Article Number: 8746 DOI: 10.1038/s41598-018-26885-5 Published: JUN 4 2018The development of high throughput SNP genotyping technologies has improved the genetic dissection of simple and complex traits in many species including cats. The properties of feline 62,897 SNPs Illumina Infinium iSelect DNA array are described using a dataset of over 2,000 feline samples, the most extensive to date, representing 41 cat breeds, a random bred population, and four wild felid species. Accuracy and efficiency of the array's genotypes and its utility in performing population-based analyses were evaluated. Average marker distance across the array was 37,741 Kb, and across the dataset, only 1% (625) of the markers exhibited poor genotyping and only 0.35% (221) showed Mendelian errors. Marker polymorphism varied across cat breeds and the average minor allele frequency (MAF) of all markers across domestic cats was 0.21. Population structure analysis confirmed a Western to Eastern structural continuum of cat breeds. Genome-wide linkage disequilibrium ranged from 50-1,500 Kb for domestic cats and 750 Kb for European wildcats (Felis silvestris silvestris). Array use in trait association mapping was investigated under different modes of inheritance, selection and population sizes. The efficient array design and cat genotype dataset continues to advance the understanding of cat breeds and will support monogenic health studies across feline breeds and populations.Peer reviewe

    Progression of pathology in PINK1-deficient mouse brain from splicing via ubiquitination, ER stress, and mitophagy changes to neuroinflammation

    Full text link

    Ascending Aortic Endograft and Thoracic Aortic Deformation After Ascending Thoracic Endovascular Aortic Repair

    No full text
    Purpose: We aim to quantify multiaxial cardiac pulsatility-induced deformation of the thoracic aorta after ascending thoracic endovascular aortic repair (TEVAR) as a part of the GORE ARISE Early Feasibility Study. Materials and Methods: Fifteen patients (7 females and 8 males, age 73\ub19 years) with ascending TEVAR underwent computed tomography angiography with retrospective cardiac gating. Geometric modeling of the thoracic aorta was performed; geometric features including axial length, effective diameter, and centerline, inner surface, and outer surface curvatures were quantified for systole and diastole; and pulsatile deformations were calculated for the ascending aorta, arch, and descending aorta. Results: From diastole to systole, the ascending endograft exhibited straightening of the centerline (0.224\ub10.039 to 0.217\ub10.039 cm−1, p<0.05) and outer surface (0.181\ub10.028 to 0.177\ub10.029 cm−1, p<0.05) curvatures. No significant changes were observed for inner surface curvature, diameter, or axial length in the ascending endograft. The aortic arch did not exhibit any significant deformation in axial length, diameter, or curvature. The descending aorta exhibited small but significant expansion of effective diameter from 2.59\ub10.46 to 2.63\ub10.44 cm (p<0.05). Conclusion: Compared with the native ascending aorta (from prior literature), ascending TEVAR damps axial and bending pulsatile deformations of the ascending aorta similar to how descending TEVAR damps descending aortic deformations, while diametric deformations are damped to a greater extent. Downstream diametric and bending pulsatility of the native descending aorta was muted compared with that in patients without ascending TEVAR (from prior literature). Deformation data from this study can be used to evaluate the mechanical durability of ascending aortic devices and inform physicians about the downstream effects of ascending TEVAR to help predict remodeling and guide future interventional strategies. Clinical Impact: This study quantified local deformations of both stented ascending and native descending aortas to reveal the biomechanical impact of ascending TEVAR on the entire thoracic aorta, and reported that the ascending TEVAR muted cardiac-induced deformation of the stented ascending aorta and native descending aorta. Understanding of in vivo deformations of the stented ascending aorta, aortic arch and descending aorta can inform physicians about the downstream effects of ascending TEVAR. Notable reduction of compliance may lead to cardiac remodeling and long-term systemic complications. This is the first report which included dedicated deformation data regarding ascending aortic endograft from clinical trial

    A randomized study of low-dose conjugated estrogens on sexual function and quality of life in postmenopausal women

    No full text
    Objective: To evaluate the effects of combined vaginal and oral low-dose estrogen plus progestogen therapy (EPT) on the frequency and severity of dyspareunia, sexual function, and quality of life in recently postmenopausal women.Methods: This outpatient, double-blind, randomized, placebo-controlled trial enrolled 285 healthy, sexually active postmenopausal women aged 45 to 65 years. Women received either one daily oral low-dose conjugated estrogens (0.45 mg)/medroxyprogesterone (1.5 mg) tablet for six 28-day cycles along with I g conjugated estrogens vaginal cream (0.625 mg), intravaginally for the first 6 weeks of the trial or a placebo cream and placebo tablet. Efficacy was evaluated using the McCoy Female Sexuality Questionnaire, self-reported daily diary cards, the Brief Index of Sexual Functioning-Women (BISF-W), and the Women's Health Questionnaire.Results: the EPT group had a significant decrease in the frequency of dyspareunia compared with baseline and placebo in an analysis of responses to the McCoy Female Sexuality Questionnaire. Also, EPT was associated with a significant improvement in a woman's level of sexual interest, frequency of orgasm, and pleasure of orgasm. There was no effect of EPT use on coital frequency. the EPT group had significant improvement in receptivity/initiation and relationship satisfaction, although not in other BISF-W domains, versus placebo (BISF-W analysis) and significant improvement versus placebo on most Women's Health Questionnaire responses.Conclusions: EPT provided a statistically significant improvement compared with placebo in dyspareunia, sexual experience, and quality of life as measured in this study. in general, EPT also improved self-reported sexual perception and enjoyment significantly compared with placebo.Wyeth, Collegeville, PAPREMARINWyeth Pharmaceut, Collegeville, PA USAMed Coll Georgia, Dept Obstet & Gynecol, Augusta, GA 30912 USAInst Saude & Ben Estar da Mulher, São Paulo, BrazilUniversidade Federal de São Paulo, Dept Gynaecol, São Paulo, BrazilLoyola Univ Chicago, Dept Obstet & Gynaecol, Maywood, IL USAUniversidade Federal de São Paulo, Dept Gynaecol, São Paulo, BrazilWeb of Scienc

    Chopstick surgery: A novel technique improves surgeon performance and eliminates arm collision in robotic single-incision laparoscopic surgery

    No full text
    Introduction Single-incision laparoscopic surgery (SILS) is limited by the coaxial arrangement of the instruments. A surgical robot with wristed instruments could overcome this limitation, but the arms often collide when working coaxially. This study tests a new technique of chopstick surgery to enable use of the robotic arms through a single incision without collision. Methods Experiments were conducted utilizing the da Vinci S® robot (Intuitive Surgical, Inc., Sunnyvale, CA) in a Fundamentals of Laparoscopic Surgery (FLS) box trainer with three laparoscopic ports (1 × 12 mm, 2 × 5 mm) introduced through a single incision. Pilot work determined the optimal setup for SILS to be a triangular port arrangement with 2-cm trocar distance and remote center at the abdominal wall. Using this setup, five experienced robotic surgeons performed three FLS tasks utilizing either a standard robotic arm setup or the chopstick technique. The chopstick arrangement crosses the instruments at the abdominal wall so that the right instrument is on the left side of the target and the left instrument on the right. This results in separation of the robotic arms outside the box. To correct for the change in handedness, the robotic console is instructed to drive the left instrument with the right-hand effector and the right instrument with the left. Performances were compared while measuring time, errors, number of clutching maneuvers, and degree of instrument collision (Likert scale 1-4). Results Compared with the standard setup, the chopstick configuration increased surgeon dexterity and global performance through significantly improved performance times, eliminating instrument collision, and decreasing number of camera manipulations, clutching maneuvers, and errors during all tasks. Conclusion Chopstick surgery significantly enhances the functionality of the surgical robot when working through a small single incision. This technique will enable surgeons to utilize the robot for SILS and possibly for intraluminal or transluminal surgery. © Springer Science+Business Media, LLC 2009
    corecore