932 research outputs found

    Note on strongly Lie nilpotent rings

    Get PDF
    This note contains a few introductory results on strongly Lie nilpotent rings and, in particular, an analogue of a well known theorem of P. Hall on nilpotent groups

    A systematic review of a polyvagal perspective on embodied contemplative practices as promoters of cardiorespiratory coupling and traumatic stress recovery for ptsd and ocd: Research methodologies and state of the art

    Get PDF
    Baseline respiratory sinus arrhythmia (RSA) has been proposed as a transdiagnostic biomarker of stress vulnerability across psychopathologies, and a reliable association between PTSD, OCD and lower resting RSA was found. Contemplative practices have been linked to the activation of the vagus as well as to an increased RSA that, according to the polyvagal theory, reflects the activation of the ventral vagal complex (VVC) and may promote PTSD and OCD recovery. PubMed and Scopus databases were selected to conduct a search following the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) 2020 guidelines, and A MeaSurement Tool to Assess systematic Reviews-2 (AMSTAR-2) was used to appraise the methodological quality for this systematic review. Six articles met the inclusion criteria (one cross-sectional study, one study with pre-post measurements, two cohort studies and two RCT studies). Mindfulness-related interventions promoted parasympathetic activity, an increased vagal tone and improvements in PTSD and OCD symptoms. According to the polyvagal theory, mindfulness-related and compassion-related meditations would be conceptualized as neural exercises expanding the capacity of the ventral vagal complex to regulate the present state and to promote resilience. Clinical and methodological issues are discussed

    Set-theoretic solutions of the Yang–Baxter equation associated to weak braces

    Get PDF
    We investigate a new algebraic structure which always gives rise to a set-theoretic solution of the Yang–Baxter equation. Specifically, a weak (left) brace is a non-empty set S endowed with two binary operations + and ∘ such that both (S, +) and (S, ∘) are inverse semigroups and a∘(b+c)=(a∘b)-a+(a∘c)anda∘a-=-a+ahold, for all a, b, c∈ S, where - a and a- are the inverses of a with respect to + and ∘ , respectively. In particular, such structures include that of skew braces and form a subclass of inverse semi-braces. Any solution r associated to an arbitrary weak brace S has a behavior close to bijectivity, namely r is a completely regular element in the full transformation semigroup on S× S. In addition, we provide some methods to construct weak braces

    New concepts for light mechanical structures of cylindrical drift chambers

    Get PDF
    A significant reduction in the amount of material at the end plates of a drift chamber can be obtained by the simple consideration of separating, in the mechanical structure, the gas containment function from the wire tension support function. According to this scheme, the wires are anchored to a self-sustaining light structure ("wire cage") surrounded by a very thin skin ("gas envelope") of suitable profile to compensate for the gas differential pressure with respect to the outside. The "wire cage" is schematically made of a set of radial spokes, constrained into a polygonal shape at the inner ends and extended to the outer endplate rim, thus subdividing the chamber in identical sectors. The drift chamber is, then, built by stacking up radially, in each of the sectors and between adjacent spokes, printed circuit boards, where the ends of the wires are soldered, alternated with proper spacers, to define the cell width. A system of adjustable tie-rods steers the wire tension to the outer endplate rim, where a rigid cylindrical carbon fibre support structure, bearing the total wire load, is attached. Two thin carbon fibre domes, free to deform under the gas pressure without affecting the wire tension and conveniently shaped to minimize the stress at the inner rim, contribute to the "gas envelope" and, together with an inner thin cylindrical foil and with the outer structural support, enclose the gas volume

    Commissioning of the MEG II tracker system

    Full text link
    The MEG experiment at the Paul Scherrer Institut (PSI) represents the state of the art in the search for the charged Lepton Flavour Violating (cLFV) μ+→e+γ\mu^+ \rightarrow e^+ \gamma decay. With the phase 1, MEG set the new world best upper limit on the \mbox{BR}(\mu^+ \rightarrow e^+ \gamma) < 4.2 \times 10^{-13} (90% C.L.). With the phase 2, MEG II, the experiment aims at reaching a sensitivity enhancement of about one order of magnitude compared to the previous MEG result. The new Cylindrical Drift CHamber (CDCH) is a key detector for MEG II. CDCH is a low-mass single volume detector with high granularity: 9 layers of 192 drift cells, few mm wide, defined by ∼12000\sim 12000 wires in a stereo configuration for longitudinal hit localization. The filling gas mixture is Helium:Isobutane (90:10). The total radiation length is 1.5×10−31.5 \times 10^{-3} \mbox{X}_0, thus minimizing the Multiple Coulomb Scattering (MCS) contribution and allowing for a single-hit resolution <120< 120 μ\mum and an angular and momentum resolutions of 6 mrad and 90 keV/c respectively. This article presents the CDCH commissioning activities at PSI after the wiring phase at INFN Lecce and the assembly phase at INFN Pisa. The endcaps preparation, HV tests and conditioning of the chamber are described, aiming at reaching the final stable working point. The integration into the MEG II experimental apparatus is described, in view of the first data taking with cosmic rays and μ+\mu^+ beam during the 2018 and 2019 engineering runs. The first gas gain results are also shown. A full engineering run with all the upgraded detectors and the complete DAQ electronics is expected to start in 2020, followed by three years of physics data taking.Comment: 10 pages, 12 figures, 1 table, proceeding at INSTR'20 conference, accepted for publication in JINS

    A 10-3 drift velocity monitoring chamber

    Full text link
    The MEG-II experiment searches for the lepton flavor violating decay: mu in electron and gamma. The reconstruction of the positron trajectory uses a cylindrical drift chamber operated with a mixture of He and iC4H10 gas. It is important to provide a stable performance of the detector in terms of its electron transport parameters, avalanche multiplication, composition and purity of the gas mixture. In order to have a continuous monitoring of the quality of gas, we plan to install a small drift chamber, with a simple geometry that allows to measure very precisely the electron drift velocity in a prompt way. This monitoring chamber will be supplied with gas coming from the inlet and the outlet of the detector to determine if gas contaminations originate inside the main chamber or in the gas supply system. The chamber is a small box with cathode walls, that define a highly uniform electric field inside two adjacent drift cells. Along the axis separating the two drift cells, four staggered sense wires alternated with five guard wires collect the drifting electrons. The trigger is provided by two 90Sr weak calibration radioactive sources placed on top of a two thin scintillator tiles telescope. The whole system is designed to give a prompt response (within a minute) about drift velocity variations at the 0.001 level

    One-Dimensional ZnO/Gold Junction for Simultaneous and Versatile Multisensing Measurements

    Get PDF
    The sensing capabilities of zinc oxide nano/micro-structures have been widely investigated and these structures are frequently used in the fabrication of cutting-edge sensors. However, to date, little attention has been paid to the multi-sensing abilities of this material. In this work, we present an efficient multisensor based on a single zinc oxide microwire/gold junction. The device is able to detect in real time three different stimuli, UV-VIS light, temperature and pH variations. This is thanks to three properties of zinc oxide its photoconductive response, pyroelectricity and surface functionalization with amino-propyl groups, respectively. The three stimuli can be detected either simultaneously or in a sequence/random order. A specific mathematical tool was also developed, together with a design of experiments (DoE), to predict the performances of the sensor. Our micro-device allows reliable and versatile real-time measurements of UV-VIS light, temperature and pH variations. Therefore, it shows great potential for use in the field of sensing for living cell cultures

    From shunt to recovery: A multidisciplinary approach to hydrocephalus treatment in severe acquired brain injury rehabilitation

    Get PDF
    Background: Hydrocephalus among Severe Acquired Brain Injury (SABI) patients remains overlooked during rehabilitation. Methods: A retrospective cohort study was carried out of traumatic and non-traumatic SABI patients with hydrocephalus, consecutively admitted over 9 years in a tertiary referral specialized rehabilitation hospital. Patients were treated with ventriculoperitoneal shunt before or during inpatient rehabilitation and assessed using the Level of Cognitive Functioning Scale and Disability Rating Scale. Logistic regression models were used to identify predictors of post-surgical complications. Linear regression models were used to investigate predictors of hospital length of stay (LOS), disability, and cognitive function. Results: Of the 82 patients, 15 had post-surgical complications and 16 underwent cranioplasty. Shunt placement complication risk was higher when fixed vs. when programmable pressure valves were used. A total of 56.3% achieved functional improvement at discharge and 88.7% improved in cognitive function; of the 82 patients, 56% were discharged home. In multiple regression analyses, higher disability at discharge was related to cranioplasty and longer LOS, while poorer cognitive function was associated with cranioplasty. Increase in LOS was associated with increasing time to shunt and decreasing age. Conclusions: A significant improvement in cognitive and functional outcomes can be achieved. Cranioplasty increased LOS, and fixed pressure valves were related to poorer outcomes

    Sorafenib and Thyroid Cancer

    Get PDF
    Sorafenib (Nexavar) is a multikinase inhibitor, which has demonstrated both anti-proliferative and anti-angiogenic properties in vitro and in vivo, inhibiting the activity of targets present in the tumor cell [c-RAF (proto-oncogene serine/threonine-protein kinase), BRAF, V600EBRAF, c-KIT, and FMS-like tyrosine kinase 3] and in tumor vessels (c-RAF, vascular endothelial growth factor receptor-2, vascular endothelial growth factor receptor-3, and platelet-derived growth factor receptor β). For several years, sorafenib has been approved for the treatment of hepatocellular carcinoma and advanced renal cell carcinoma. After previous studies showing that sorafenib was able to inhibit oncogenic RET mutants, V600EBRAF, and angiogenesis and growth of orthotopic anaplastic thyroid cancer xenografts in nude mice, some clinical trials demonstrated the effectiveness of sorafenib in advanced thyroid cancer. Currently, the evaluation of the clinical safety and efficacy of sorafenib for the treatment of advanced thyroid cancer is ongoing. This article reviews the anti-neoplastic effect of sorafenib in thyroid cancer. Several completed (or ongoing) studies have evaluated the long-term efficacy and tolerability of sorafenib in patients with papillary and medullary aggressive thyroid cancer. The results suggest that sorafenib is a promising therapeutic option in patients with advanced thyroid cancer that is not responsive to traditional therapeutic strategies
    • …
    corecore