87 research outputs found

    Il calcio coronarico come marker precoce di aterosclerosi

    Get PDF
    Non-invasive diagnostic techniques such as electron beam computed tomography and multislice spiral computed tomography are able to detect and quantify coronary calcifications. Several clinical studies have shown how the amount of coronary calcifications correlates to the coronary plaque burden. The detection of coronary calcium therefore provides a unique opportunity to identify and quantify coronary atherosclerosis in a subclinical stage. Measures of subclinical atherosclerosis may also help in recognizing factors related to atherosclerosis in asymptomatic populations. In addition, a significant proportion of subjects who develop premature clinical disease are not identified as being at high risk by current strategies. A scan negative for coronary calcium has a high negative predictive value indicating the absence of stenotic coronary artery disease. The aim of this review was to describe the potentials of coronary calcium detection and to summarize its clinical relevance. © 2005 CEPI Srl

    Spatial segregation of Darwinula stevensoni (Crustacea: Ostracoda) genotypes in lentic and lotic habitats of Northern Italy

    Get PDF
    The clonal structure of apomictic populations of Darwinula stevensoni from Northern Italy lacustrine and riverine habitats has been analysed by allozyme electrophoresis. Thirty two sites were sampled and a total of 748 individuals were analysed. Only one polymorphic locus, Gpi, turned out to have enough variation to be informative. Two thirds of all individuals were homozygous for the most frequent allele but the frequency of this genotype was significantly lower in rivers (16%) than in lakes (92%). As a consequence homozygous clonal females are dominant in lacustrine habitats while heterozygous clonal females are dominant in riverine ones. Differences in genetic structure between habitats were observed even at distances of a few meters. Allele and genotype frequencies are significantly different between Lake Montorfano and its outflow (River Seveso) and between Mantova lakes and their two tributaries, the River Mincio and Corniano Channel. The former is also the outflow of Lake Garda. By laboratory experiments, we previously reported difference between genotypes: homozygous females from Mantova lakes show significantly lower starvation tolerance than heterozygous females from River Mincio. We discuss the hypothesis that habitat segregation is related to this difference. Riverine females should be better adapted to low productivity ecosystems than lacustrine ones

    An abnormal neural reflex plays a role in causing syncope in sinus bradycardia

    Get PDF
    AbstractObjectives. This study Investigates the rote of an abnormal neural reflex in causing syncope in patients with sinus bradycardia.Background. Syncope is commonly considered an indication of severity in sinus bradycardia. However, the occurrence of syncope is unpredictable, and the prognosis appears to be similar in patients with and without syncope.Methods. Head-up tilt testing (60 ° for 60 min), carotid sinus massage in the supine and standing positions, 24-h Bolter ambulatory electrocardiographic (ECG) recording and etectrophysiologic study before and after pharmacologic autonomic blockade were performed in 25 patients with sinus bradycardia and syncope (group I, sinus rate <50 beats/min, age 71 ± 12 years) and 25 patients with sinus bradycardia and no neurologic symptoms (group II, sinus rate <50 beats/min, age 67 ± 16 years).Results. Clinical characteristics and ambulatory ECG monitoring data were similar in the two study groups. A positive response (induction of syncope or presyncope with hypotension and/or bradycardia) was obtained by head-up tilt testing in 15 group I (60%) and in 3 group II (12%) patients (p < 0.001) and by carotid sinus massage in 11 group I (44%) and 6 group II (24%) patients (p = NS). Results of at least one test (head-up tilt testing or carotid sinus massage, or both) were positive in 19 group I (76%) and 9 group II (36%) patients (p < 0.01). Basal and intrinsic corrected sinus node recovery time did not differ significantly between the two groups. An abnormal intrinsic heart rate was present in 66% of group I and 26% of group II patients (p < 0.01). The different percentage of positive findings on head-up tilt testing and carotid sinus massage in the two groups was independent of the presence of intrinsic sinus node dysfunction.Conclusions. These results indicate that an abnormal neural reflex plays a role in causing syncope in patients with sinus bradycardia. This reflex seems to be unrelated to the severity of sinus node dysfunction, even if the latter could enhance the cardioinhibitory response

    Theoretical and practical aspects of the design and production of synthetic holograms for transmission electron microscopy

    Get PDF
    Beam shaping-the ability to engineer the phase and the amplitude of massive and massless particles-has long interested scientists working on communication, imaging, and the foundations of quantum mechanics. In light optics, the shaping of electromagnetic waves (photons) can be achieved using techniques that include, but are not limited to, direct manipulation of the beam source (as in X-ray free electron lasers and synchrotrons), deformable mirrors, spatial light modulators, mode converters, and holograms. The recent introduction of holographic masks for electrons provides new possibilities for electron beam shaping. Their fabrication has been made possible by advances in micrometric and nanometric device production using lithography and focused on ion beam patterning. This article provides a tutorial on the generation, production, and analysis of synthetic holograms for transmission electron microscopy. It begins with an introduction to synthetic holograms, outlining why they are useful for beam shaping to study material properties. It then focuses on the fabrication of the required devices from theoretical and experimental perspectives, with examples taken from both simulations and experimental results. Applications of synthetic electron holograms as aberration correctors, electron vortex generators, and spatial mode sorters are then presented

    Genetic determinants in a critical domain of ns5a correlate with hepatocellular carcinoma in cirrhotic patients infected with hcv genotype 1b

    Get PDF
    HCV is an important cause of hepatocellular carcinoma (HCC). HCV NS5A domain‐1 interacts with cellular proteins inducing pro‐oncogenic pathways. Thus, we explore genetic variations in NS5A domain‐1 and their association with HCC, by analyzing 188 NS5A sequences from HCV genotype‐1b infected DAA‐naïve cirrhotic patients: 34 with HCC and 154 without HCC. Specific NS5A mutations significantly correlate with HCC: S3T (8.8% vs. 1.3%, p = 0.01), T122M (8.8% vs. 0.0%, p &lt; 0.001), M133I (20.6% vs. 3.9%, p &lt; 0.001), and Q181E (11.8% vs. 0.6%, p &lt; 0.001). By multivariable analysis, the presence of &gt;1 of them independently correlates with HCC (OR (95%CI): 21.8 (5.7–82.3); p &lt; 0.001). Focusing on HCC‐group, the presence of these mutations correlates with higher viremia (median (IQR): 5.7 (5.4–6.2) log IU/mL vs. 5.3 (4.4–5.6) log IU/mL, p = 0.02) and lower ALT (35 (30–71) vs. 83 (48–108) U/L, p = 0.004), suggesting a role in enhancing viral fitness without affecting necroinflammation. Notably, these mutations reside in NS5A regions known to interact with cellular proteins crucial for cell‐cycle regulation (p53, p85‐PIK3, and β‐ catenin), and introduce additional phosphorylation sites, a phenomenon known to ameliorate NS5A interaction with cellular proteins. Overall, these results provide a focus for further investigations on molecular bases of HCV‐mediated oncogenesis. The role of these NS5A domain‐1 mutations in triggering pro‐oncogenic stimuli that can persist also despite achievement of sustained virological response deserves further investigation

    Effectiveness of cardiac resynchronization therapy in heart failure patients with valvular heart disease: comparison with patients affected by ischaemic heart disease or dilated cardiomyopathy. The InSync/InSync ICD Italian Registry

    Get PDF
    AimsTo analyse the effectiveness of cardiac resynchronization therapy (CRT) in patients with valvular heart disease (a subset not specifically investigated in randomized controlled trials) in comparison with ischaemic heart disease or dilated cardiomyopathy patients.Methods and resultsPatients enrolled in a national registry were evaluated during a median follow-up of 16 months after CRT implant. Patients with valvular heart disease treated with CRT (n = 108) in comparison with ischaemic heart disease (n = 737) and dilated cardiomyopathy (n = 635) patients presented: (i) a higher prevalence of chronic atrial fibrillation, with atrioventricular node ablation performed in around half of the cases; (ii) a similar clinical and echocardiographic profile at baseline; (iii) a similar improvement of LVEF and a similar reduction in ventricular volumes at 6-12 months; (iv) a favourable clinical response at 12 months with an improvement of the clinical composite score similar to that occurring in patients with dilated cardiomyopathy and more pronounced than that observed in patients with ischaemic heart disease; (v) a long-term outcome, in term of freedom from death or heart transplantation, similar to patients affected by ischaemic heart disease and basically more severe than that of patients affected by dilated cardiomyopathy.ConclusionIn 'real world' clinical practice, CRT appears to be effective also in patients with valvular heart disease. However, in this group of patients the outcome after CRT does not precisely overlap any of the two other groups of patients, for which much more data are currently available

    Understanding Factors Associated With Psychomotor Subtypes of Delirium in Older Inpatients With Dementia

    Get PDF

    Mission Scientifique de l\u27Omo. Tome IV. Fascicule 34 : Orthoptera. II. Dermaptera

    No full text
    Volume: 8Start Page: 135End Page: 14

    In-Place Characterization of On-State Voltage for SiC MOSFETs: Controlled Shoot-Through vs. Film Heater

    No full text
    The on-state voltage of MOSFETs is a convenient and powerful temperature-sensitive electric parameter (TSEP) to determine the junction temperature, thus enabling device monitoring, protection, diagnostics and prognostics. The main hurdle in the use of the on-state voltage as a TSEP is the per-device characterization procedure, to be carried out in a controlled environment, with high costs. In this paper, we compare two novel techniques for MOSFET junction temperature estimation: controlled shoot-through and direct heating by resistive heaters embedded in two Kapton (polyimide) films. Both allow in-place characterization of the TSEP curve with the device mounted in its final circuit and assembly, including the working heat sink. The two methods are also validated against the conventional procedure in a thermal chamber
    corecore