244 research outputs found

    Bullous central serous chorioretinopathy: A rare and atypical form of central serous chorioretinopathy. a systematic review

    Get PDF
    Bullous central serous chorioretinopathy (bCSCR) is a rare variant of the central serous chorioretinopathy, complicated by an exudative retinal detachment with shifting fluid. This systematic review aims to present the epidemiology, the pathogenesis, the clinical presentation, the imaging, the differential diagnosis, and the latest treatments of this disease. A total of 60 studies were identified following a literature search adhering to PRISMA guidelines. After full-text evaluation, 34 studies about bCSCR were included. bCSCR usually affects middle-aged men, and the principal risk factor is corticosteroid medications. Pathogenesis is related to an increased choroidal vessel and choriocapillaris permeability, with subsequent subretinal fluid accumulation, rich in fibrin, which may provoke the exudative retinal detachment. Clinical presentation and imaging are fundamental to distinguish bCSCR from other pathologies, avoiding unappropriated treatment. Corticosteroid withdraws (if assumed) and laser photocoagulation of leakage sites seen at angiography may speed up retinal reattachment. Verteporfin photodynamic therapy, transpupillary thermal therapy, oral eplerenone and scleral thinning surgery are other therapeutic options. An early diagnosis might prevent disease progression due to harmful medications as well as unnecessary surgery

    Fungal endogenous endophthalmitis secondary to magnusiomyces capitatus

    Get PDF
    We report the case of a 68-year-old immunocompetent patient with a dilatation of the ascending aorta, intraluminal vegetations, and pseudoaneurysmatic bulging who presented with unilateral fungal endogenous endophthalmitis 8 days after coronary angiogram. The isolated pathogen resulted to be Magnusiomyces capitatus, a filamentous, yeast-like fungus that can be commonly found in normal human microflora, with an immunosuppression-related pathogenicity. A literature research revealed a single case of ophthalmic infection - a keratitis - caused by this pathogen. Furthermore, we add a review of mycotic endophthalmitis related to aortic infection

    Eunice rubra Grube (Annelida, Polychaeta, Eunicidae), a redescription based on the holotype and Brazilian specimens

    Get PDF
    Based on features of the holotype and seven Brazilian specimens examined under stereomicroscope, light microscope, and scanning electron microscope, Eunice rubra Grube, 1856 is redescribed, allowing for intraspecific variation and providing informationon characters not included in a previous redescription. Characters important for the taxonomy of the genus varied widely, although in some cases because of fixation artefacts.243259Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq

    Integrated plan for the sustainable management of the Lagoon of Marano and Grado

    Get PDF
    The Lagoon of Marano and Grado has been experiencing some remarkable environmental impacts, which have affected the high-value natural ecosystem and consequently influenced relevant socio-economic aspects. One of the main problems relates to the diffuse contamination of soil and groundwater in the mainland, as well as sediments in rivers and in the lagoon itself. The need to ensure safe navigation conditions in the lagoon and in the Corno River serving Porto Nogaro harbour is another critical emergency. Other environmental issues of concern are: loss of morphological diversity, watershed basins’ pollution loads and protection of lagoon habitats. Due to the emergency situation, a Special Commissioner has been appointed by the national government to proceed with the resolution of the most critical problems. A specific “Operational Plan of interventions” was therefore elaborated in 2009. Approaching problems and solutions in an integrated way, the Plan represents one of the tools for the sustainable development of the lagoon. It strongly supports the adoption of adaptive management, foreseeing the periodical updating and improvement of objectives, strategies and interventions. The Plan also identifies the need for coordination among institutions and involvement of stakeholders as key elements for the implementation of adaptive management

    Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy

    Get PDF
    Background Diabetic macular oedema (DMO) is a thickening of the central retina, or the macula, and is associated with long-term visual loss in people with diabetic retinopathy (DR). Clinically significant macular oedema (CSMO) is the most severe form of DMO. Almost 30 years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS) found that CSMO, diagnosed by means of stereoscopic fundus photography, leads to moderate visual loss in one of four people within three years. It also showed that grid or focal laser photocoagulation to the macula halves this risk. Recently, intravitreal injection of antiangiogenic drugs has also been used to try to improve vision in people with macular oedema due to DR. Optical coherence tomography (OCT) is based on optical reflectivity and is able to image retinal thickness and structure producing cross-sectional and three-dimensional images of the central retina. It is widely used because it provides objective and quantitative assessment ofmacular oedema, unlike the subjectivity of fundus biomicroscopic assessment which is routinely used by ophthalmologists instead of photography. Optical coherence tomography is also used for quantitative follow-up of the effects of treatment of CSMO. Objectives To determine the diagnostic accuracy of OCT for detecting DMO and CSMO, defined according to ETDRS in 1985, in patients referred to ophthalmologists afterDR is detected. In the update of this review we also aimed to assess whetherOCTmight be considered the new reference standard for detecting DMO. Search methods We searched the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA) and the NHS Economic Evaluation Database (NHSEED) (The Cochrane Library 2013, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2013), EMBASE (January 1950 to June 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1990 to June 2013), BIOSIS Previews (January 1969 to June 2013), MEDION and the Aggressive Research Intelligence Facility database (ARIF).We did not use any date or language restrictions in the electronic searches for trials.We last searched the electronic databases on 25 June 2013.We checked bibliographies of relevant studies for additional references. Selection criteria We selected studies that assessed the diagnostic accuracy of anyOCTmodel for detectingDMOorCSMOin patientswithDR whowere referred to eye clinics. Diabetic macular oedema and CSMO were diagnosed by means of fundus biomicroscopy by ophthalmologists or stereophotography by ophthalmologists or other trained personnel. Data collection and analysis Three authors independently extracted data on study characteristics and measures of accuracy. We assessed data using random-effects hierarchical sROC meta-analysis models. Main results We included 10 studies (830 participants, 1387 eyes), published between 1998 and 2012. Prevalence of CSMO was 19% to 65% (median 50%) in nine studies with CSMO as the target condition. Study quality was often unclear or at high risk of bias for QUADAS 2 items, specifically regarding study population selection and the exclusion of participants with poor quality images. Applicablity was unclear in all studies since professionals referring patients and results of prior testing were not reported. There was a specific 'unit of analysis' issue because both eyes of the majority of participants were included in the analyses as if they were independent. In nine studies providing data on CSMO (759 participants, 1303 eyes), pooled sensitivity was 0.78 (95%confidence interval (CI) 0.72 to 0.83) and specificity was 0.86 (95% CI 0.76 to 0.93). The median central retinal thickness cut-off we selected for data extraction was 250 \uce\ubcm (range 230 \uce\ubcm to 300 \uce\ubcm). Central CSMO was the target condition in all but two studies and thus our results cannot be applied to non-central CSMO. Data from three studies reporting accuracy for detection of DMO (180 participants, 343 eyes) were not pooled. Sensitivities and specificities were about 0.80 in two studies and were both 1.00 in the third study. Since this review was conceived, the role of OCT has changed and has become a key ingredient of decision-making at all levels of ophthalmic care in this field.Moreover, disagreements between OCT and fundus examination are informative, especially false positives which are referred to as subclinical DMO and are at higher risk of developing clinical CSMO. Authors' conclusions Using retinal thickness thresholds lower than 300 \uce\ubcm and ophthalmologist's fundus assessment as reference standard, central retinal thickness measured with OCT was not sufficiently accurate to diagnose the central type of CSMO in patients with DR referred to retina clinics. However, at least OCT false positives are generally cases of subclinical DMO that cannot be detected clinically but still suffer from increased risk of disease progression. Therefore, the increasing availability of OCT devices, together with their precision and the ability to inform on retinal layer structure, now make OCT widely recognised as the new reference standard for assessment of DMO, even in some screening settings. Thus, this review will not be updated further

    Bronchial artery embolization for management of massive cryptogenic hemoptysis: a case series

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Hemoptysis constitutes a common and urgent medical problem. Swift and effective management is of crucial importance, especially in severe, life-threatening cases. In cases of idiopathic hemoptysis, in which no underlying pulmonary pathology can be identified, treatment is challenging. We report our experience with bronchial artery embolization in the treatment of massive idiopathic hemoptysis.</p> <p>Cases presentation</p> <p>We report three consecutive cases of acute severe idiopathic hemoptysis. Our patients (two men aged 51 and 56 years and one woman aged 46 years), were of Caucasian ethnicity. We discuss the results and management of the patients, and review the literature. All three patients were treated safely and successfully with transcatheter embolization of the bronchial arteries using tris-acryl gelatin microspheres. Hemoptysis was controlled. All cases were followed up for 12 months, and there was no recurrence of bleeding.</p> <p>Conclusion</p> <p>Bronchial artery embolization is an effective tool for the evaluation and treatment of massive idiopathic hemoptysis.</p

    Vascular risk factors in glaucoma: the results of a national survey

    Get PDF
    Background The role of vascular risk factors in glaucoma is still being debated. To assess the importance of vascular risk factors in patients with primary open-angle glaucoma (POAG), data from the medical history of 2,879 POAG patients and 973 age-matched controls were collected and analyzed. Methods Design: observational survey. Setting: 35 Italian academic centers. Study population: POAG patients and age-matched controls. In order to reduce bias consecutive patients were included. Observation procedures: data concerning vascular risk factors were collected for all patients with a detailed questionnaire. A complete ophthalmological examination with assessment of intraocular pressure (IOP), visual field, optic disc, and systemic blood pressure was performed. Main outcome measures: the ESH-ESC (European Society of Hypertension-European Society of Cardiology) guidelines were used to calculate the level of cardiovascular risk. Crude and adjusted estimates of the odds ratios (OR) were calculated for all cardiovascular risk factors in POAG and controls. Results The study included 2,879 POAG patients and 973 controls. POAG cases had a significantly higher systolic and diastolic blood pressure (p=0.001) and systolic perfusion pressure (p=0.02) as compared with controls. Also mean IOP was significantly higher in the POAG group (p=0.01), while diastolic perfusion pressure was not significantly different in the two groups. Myopia was more prevalent in the POAG group (23 vs 18%, p=0.005) as well as a positive family history for glaucoma (26 vs 12%, p= 0.004). POAG patients tended to have a higher cardiovascular risk than controls: 63% of glaucoma cases vs 55% of controls (OR: 1.38, p=0.005) had a “high” or “very high” cardiovascular risk. Conclusions The level of cardiovascular risk was significantly higher in glaucoma patients than in controls
    • …
    corecore