7,961 research outputs found
Performance of prototype BTeV silicon pixel detectors in a high energy pion beam
The silicon pixel vertex detector is a key element of the BTeV spectrometer.
Sensors bump-bonded to prototype front-end devices were tested in a high energy
pion beam at Fermilab. The spatial resolution and occupancies as a function of
the pion incident angle were measured for various sensor-readout combinations.
The data are compared with predictions from our Monte Carlo simulation and very
good agreement is found.Comment: 24 pages, 20 figure
Search for CP Violation in the decays D+ -> K_S pi+ and D+ -> K_S K+
A high statistics sample of photo-produced charm from the FOCUS(E831)
experiment at Fermilab has been used to search for direct CP violation in the
decays D+->K_S pi+ and D+ -> K_S K+. We have measured the following asymmetry
parameters relative to D+->K-pi+pi+: A_CP(K_S pi+) = (-1.6 +/- 1.5 +/- 0.9)%,
A_CP(K_S K+) = (+6.9 +/- 6.0 +/- 1.5)% and A_CP(K_S K+) = (+7.1 +/- 6.1 +/-
1.2)% relative to D+->K_S pi+. The first errors quoted are statistical and the
second are systematic. We also measure the relative branching ratios:
\Gamma(D+->\bar{K0}pi+)/\Gamma(D+->K-pi+pi+) = (30.60 +/- 0.46 +/- 0.32)%,
\Gamma(D+->\bar{K0}K+)/\Gamma(D+->K-pi+pi+) = (6.04 +/- 0.35 +/- 0.30)% and
\Gamma(D+->\bar{K0}K+)/\Gamma(D+->\bar{K0}pi+) = (19.96 +/- 1.19 +/- 0.96)%.Comment: 4 pages, 3 figure
New FOCUS results on charm mixing and CP violation
We present a summary of recent results on CP violation and mixing in the
charm quark sector based on a high statistics sample collected by
photoproduction experiment FOCUS (E831 at Fermilab). We have measured the
difference in lifetimes for the decays: and . This translates into a measurement of the mixing parameter in
the \d0d0 system, under the assumptions that is an equal mixture of
CP odd and CP even eigenstates, and CP violation is negligible in the neutral
charm meson system. We verified the latter assumption by searching for a CP
violating asymmetry in the Cabibbo suppressed decay modes , and . We show preliminary
results on a measurement of the branching ratio .Comment: 9 pages, 6 figures, requires espcrc2.sty. Presented by S.Bianco at
CPConf2000, September 2000, Ferrara (Italy). In this revision, fixed several
stylistic flaws, add two significant references, fixed a typo in Tab.
Search for CP violation in D0 and D+ decays
A high statistics sample of photoproduced charm particles from the FOCUS
(E831) experiment at Fermilab has been used to search for CP violation in the
Cabibbo suppressed decay modes D+ to K-K+pi+, D0 to K-K+ and D0 to pi-pi+. We
have measured the following CP asymmetry parameters: A_CP(K-K+pi+) = +0.006 +/-
0.011 +/- 0.005, A_CP(K-K+) = -0.001 +/- 0.022 +/- 0.015 and A_CP(pi-pi+) =
+0.048 +/- 0.039 +/- 0.025 where the first error is statistical and the second
error is systematic. These asymmetries are consistent with zero with smaller
errors than previous measurements.Comment: 12 pages, 4 figure
Study of Cabibbo Suppressed Decays of the Ds Charmed-Strange Meson involving a KS
We study the decay of Ds meson into final states involving a Ks and report
the discovery of Cabibbo suppressed decay modes Ds -> Kspi-pi+pi+ (179 +/- 36
events) and Ds -> Kspi+ (113 +/-26 events). The branching ratios for the new
modes are Gamma(Ds -> Kspi-pi+pi+)/Gamma(Ds -> KsK-pi+pi+) = 0.18 +/- 0.04 +/-
0.05 and Gamma(Ds -> Kspi+)/Gamma(Ds -> KsK+) = 0.104 +/- 0.024 +/- 0.013.Comment: 11 pages, 6 figure
Search for CP violation in D0 and D+ decays
A high statistics sample of photoproduced charm particles from the FOCUS
(E831) experiment at Fermilab has been used to search for CP violation in the
Cabibbo suppressed decay modes D+ to K-K+pi+, D0 to K-K+ and D0 to pi-pi+. We
have measured the following CP asymmetry parameters: A_CP(K-K+pi+) = +0.006 +/-
0.011 +/- 0.005, A_CP(K-K+) = -0.001 +/- 0.022 +/- 0.015 and A_CP(pi-pi+) =
+0.048 +/- 0.039 +/- 0.025 where the first error is statistical and the second
error is systematic. These asymmetries are consistent with zero with smaller
errors than previous measurements.Comment: 12 pages, 4 figure
Dalitz plot analysis of D_s+ and D+ decay to pi+pi-pi+ using the K-matrix formalism
FOCUS results from Dalitz plot analysis of D_s+ and D+ to pi+pi-pi+ are
presented. The K-matrix formalism is applied to charm decays for the first time
to fully exploit the already existing knowledge coming from the light-meson
spectroscopy experiments. In particular all the measured dynamics of the S-wave
pipi scattering, characterized by broad/overlapping resonances and large
non-resonant background, can be properly included. This paper studies the
extent to which the K-matrix approach is able to reproduce the observed Dalitz
plot and thus help us to understand the underlying dynamics. The results are
discussed, along with their possible implications on the controversial nature
of the sigma meson.Comment: To be submitted to Phys.Lett.B A misprint corrected in formula
Beam Test Results of the BTeV Silicon Pixel Detector
The results of the BTeV silicon pixel detector beam test carried out at
Fermilab in 1999-2000 are reported. The pixel detector spatial resolution has
been studied as a function of track inclination, sensor bias, and readout
threshold.Comment: 8 pages of text, 8 figures, Proceedings paper of Pixel 2000:
International Workshop on Semiconductor Pixel Detectors for Particles and
X-Rays, Genova, June 5-8, 200
A Measurement of the Ds+ Lifetime
A high statistics measurement of the Ds+ lifetime from the Fermilab
fixed-target FOCUS photoproduction experiment is presented. We describe the
analysis of the two decay modes, Ds+ -> phi(1020)pi+ and Ds+ ->
\bar{K}*(892)0K+, used for the measurement. The measured lifetime is 507.4 +/-
5.5 (stat.) +/- 5.1 (syst.) fs using 8961 +/- 105 Ds+ -> phi(1020)pi+ and 4680
+/- 90 Ds+ -> \bar{K}*(892)0K+ decays. This is a significant improvement over
the present world average.Comment: 5 pages, 3 figures, 2 tables, submitted to PR
Beam Test of BTeV Pixel Detectors
The silicon pixel vertex detector is one of the key elements of the BTeV
spectrometer. Detector prototypes were tested in a beam at Fermilab. We report
here on the measured spatial resolution as a function of the incident angles
for different sensor-readout electronics combinations. We compare the results
with predictions from our Monte Carlo simulation.Comment: 7 pages, 5 figures, Invited talk given by J.C. Wang at "Vertex 2000,
9th International Workshop on Vertex Detectors", Michigan, Sept 10-15, 2000.
To be published in NIM
- …
