6,312 research outputs found

    Magnetization reversal and local switching fields of ferromagnetic Co/Pd microtubes with radial magnetization

    Get PDF
    Three-dimensional nanomagnetism is a rapidly growing field of research covering both noncollinear spin textures and curved magnetic geometries including microtubular structures. We spatially resolve the field-induced magnetization reversal of free-standing ferromagnetic microtubes utilizing multifrequency magnetic force microscopy (MFM). The microtubes are composed of Co/Pd multilayer films with perpendicular magnetic anisotropy that translates to an anisotropy with radial easy axis upon rolling-up. Simultaneously mapping the topography and the perpendicular magnetostatic force derivative, the relation between surface angle and local magnetization configuration is evaluated for a large number of locations with slopes exceeding 45 degrees. The angle-dependence of the switching field is concurrent with the Kondorsky model, i.e., the rolled-up nanomembrane behaves like a planar magnetic film with perpendicular anisotropy and a pinning dominated magnetization reversal. Additionally, we discuss methodological challenges when detecting magnetostatic force derivatives near steep surfaces

    Self-consistent model of unipolar transport in organic semiconductor diodes: accounting for a realistic density-of-states distribution

    Full text link
    A self-consistent, mean-field model of charge-carrier injection and unipolar transport in an organic semiconductor diode is developed utilizing the effective transport energy concept and taking into account a realistic density-of-states distribution as well as the presence of trap states in an organic material. The consequences resulting from the model are discussed exemplarily on the basis of an indium tin oxide/organic semiconductor/metallic conductor structure. A comparison of the theory to experimental data of a unipolar indium tin oxide/poly-3-hexyl-thiophene/Al device is presented.Comment: 6 pages, 2 figures; to be published in Journal of Applied Physic

    Self consistent theory of unipolar charge-carrier injection in metal/insulator/metal systems

    Full text link
    A consistent device model to describe current-voltage characteristics of metal/insulator/metal systems is developed. In this model the insulator and the metal electrodes are described within the same theoretical framework by using density of states distributions. This approach leads to differential equations for the electric field which have to be solved in a self consistent manner by considering the continuity of the electric displacement and the electrochemical potential in the complete system. The model is capable of describing the current-voltage characteristics of the metal/insulator/metal system in forward and reverse bias for arbitrary values of the metal/ insulator injection barriers. In the case of high injection barriers, approximations are provided offering a tool for comparison with experiments. Numerical calculations are performed exemplary using a simplified model of an organic semiconductor.Comment: 21 pages, 8 figure

    Economic inequalities in burden of illness, diagnosis and treatment of five long-term conditions in England: panel study

    Get PDF
    We compared the distribution by wealth of self-reported illness burden (estimated from validated scales, biomarker and reported symptoms) for angina, cataract, depression, diabetes and osteoarthritis, with the distribution of self-reported medical diagnosis and treatment. We aimed to determine if the greater illness burden borne by poorer participants was matched by appropriately higher levels of diagnosis and treatment

    Spectroscopic biomedical imaging with the Medipix2 detector

    Get PDF
    This study confirms that the Medipix2 x-ray detector enables spectroscopic bio-medical plain radiography. We show that the detector has the potential to provide new, useful information beyond the limited spectroscopic information of modern dual-energy computed tomography (CT) scanners. Full spectroscopic 3D-imaging is likely to be the next major technological advance in computed tomography, moving the modality towards molecular imaging applications. This paper focuses on the enabling technology which allows spectroscopic data collection and why this information is useful. In this preliminary study we acquired the first spectroscopic images of human tissue and other biological samples obtained using the Medipix2 detector. The images presented here include the clear resolution of the 1.4mm long distal phalanx of a 20-week-old miscarried foetus, showing clear energy-dependent variations. The opportunities for further research using the forthcoming Medipix3 detector are discussed and a prototype spectroscopic CT scanner (MARS, Medipix All Resolution System) is briefly describe

    Stationary Velocity and Charge Distributions of Grains in Dusty Plasmas

    Get PDF
    Within the kinetic approach velocity and charge distributions of grains in stationary dusty plasmas are calculated and the relations between the effective temperatures of such distributions and plasma parameters are established. It is found that the effective temperature which determines the velocity grain distribution could be anomalously large due to the action of accelerating ionic bombarding force. The possibility to apply the results obtained to the explanation of the increasing grain temperature in the course of the Coulomb-crystal melting by reduction of the gas pressure is discussed. This paper was received by Phys.Rev.Lett. on 11 August 1999. As potential referees the authors offered to Editor the following persons: V.N.Tsytovich, Russia; R.Bingham, UK; D.Resendes, Portugal; G.Morfill, P.Shukla, Y.M.Yu., Germany.Comment: 8 pages, no figure

    Events in Early Life are Associated with Female Reproductive Ageing: A UK Biobank Study.

    Get PDF
    The available oocyte pool is determined before birth, with the majority of oocytes lost before puberty. We hypothesised that events occurring before birth, in childhood or in adolescence ('early-life risk factors') could influence the size of the oocyte pool and thus the timing of menopause. We included cross-sectional data from 273,474 women from the UK Biobank, recruited in 2006-2010 from across the UK. We analysed the association of early menopause with events occurring before adulthood in 11,781 cases (menopause aged under 45) and 173,641 controls (menopause/pre-menopausal at ≥ 45 years), in models controlling for potential confounding variables. Being part of a multiple birth was strongly associated with early menopause (odds ratio = 1.42, confidence interval: 1.11, 1.82, P = 8.0 × 10(-9), fully-adjusted model). Earlier age at menarche (odds ratio = 1.03, confidence interval: 1.01, 1.06, P = 2.5 × 10(-6)) and earlier year of birth were also associated with EM (odds ratio = 1.02, confidence interval: 1.00, 1.04, P = 8.0 × 10(-6)). We also confirmed previously reported associations with smoking, drinking alcohol, educational level and number of births. We identified an association between multiple births and early menopause, which connects events pre-birth, when the oocyte pool is formed, with reproductive ageing in later life.This research has been conducted using the UK Biobank Resource. This work was generously supported by a Wellcome Trust Institutional Strategic Support Award [WT097835MF to University of Exeter].This is the final version of the article. It first appeared from Nature Publishing Group via http://dx.doi.org/10.1038/srep2471

    Self-consistent analytical solution of a problem of charge-carrier injection at a conductor/insulator interface

    Full text link
    We present a closed description of the charge carrier injection process from a conductor into an insulator. Common injection models are based on single electron descriptions, being problematic especially once the amount of charge-carriers injected is large. Accordingly, we developed a model, which incorporates space charge effects in the description of the injection process. The challenge of this task is the problem of self-consistency. The amount of charge-carriers injected per unit time strongly depends on the energy barrier emerging at the contact, while at the same time the electrostatic potential generated by the injected charge- carriers modifies the height of this injection barrier itself. In our model, self-consistency is obtained by assuming continuity of the electric displacement and the electrochemical potential all over the conductor/insulator system. The conductor and the insulator are properly taken into account by means of their respective density of state distributions. The electric field distributions are obtained in a closed analytical form and the resulting current-voltage characteristics show that the theory embraces injection-limited as well as bulk-limited charge-carrier transport. Analytical approximations of these limits are given, revealing physical mechanisms responsible for the particular current-voltage behavior. In addition, the model exhibits the crossover between the two limiting cases and determines the validity of respective approximations. The consequences resulting from our exactly solvable model are discussed on the basis of a simplified indium tin oxide/organic semiconductor system.Comment: 23 pages, 6 figures, accepted to Phys.Rev.
    • …
    corecore