54 research outputs found

    Performance limitations of small-format high-speed infrared arrays for active control loops in interferometry and adaptive optics

    Get PDF
    The detector mounted in the VLTI fringe sensor FINITO is a 256x256 HgCdTe array with a cut-off wavelength of 1.9 micron. The same arrays having cut-off wavelengths of 2.5 micron will be used in the tip tilt sensor IRIS and the PRIMA instrument of the VLT interferometer. The arrays are part of an active control loop with integration times as short as a few hundred microseconds. The fringe tracker FINITO uses only 7 pixels of the array. To take advantage of the four parallel channels of the PICNIC multiplexer, the pixels illuminated in each quadrant are positioned at the same location within the quadrants. A noise analysis of the PICNIC array shows that the main sensitivity limitation of the array is contained in the low frequency part of the noise power spectrum. Similar behaviour has been observed with other infrared arrays. In an effort to optimize the unit cell pixel buffer to achieve high speed and low noise, a prototype multiplexer is being developed at Rockwell for adaptive optics. However, low frequency noise may still be the limiting factor dominating the noise performance of infrared arrays. To overcome this noise barrier, detector architectures have to be envisaged which should allow double correlated sampling on shorter time scales than a full exposure. This might be accomplished by some kind of gate in the IR material which allows charge to be shifted from an integrating well in the infrared pixel to a small sensing node capacitance of the multiplexer unit cell buffer

    An overview of the mid-infrared spectro-interferometer MATISSE: science, concept, and current status

    Full text link
    MATISSE is the second-generation mid-infrared spectrograph and imager for the Very Large Telescope Interferometer (VLTI) at Paranal. This new interferometric instrument will allow significant advances by opening new avenues in various fundamental research fields: studying the planet-forming region of disks around young stellar objects, understanding the surface structures and mass loss phenomena affecting evolved stars, and probing the environments of black holes in active galactic nuclei. As a first breakthrough, MATISSE will enlarge the spectral domain of current optical interferometers by offering the L and M bands in addition to the N band. This will open a wide wavelength domain, ranging from 2.8 to 13 um, exploring angular scales as small as 3 mas (L band) / 10 mas (N band). As a second breakthrough, MATISSE will allow mid-infrared imaging - closure-phase aperture-synthesis imaging - with up to four Unit Telescopes (UT) or Auxiliary Telescopes (AT) of the VLTI. Moreover, MATISSE will offer a spectral resolution range from R ~ 30 to R ~ 5000. Here, we present one of the main science objectives, the study of protoplanetary disks, that has driven the instrument design and motivated several VLTI upgrades (GRA4MAT and NAOMI). We introduce the physical concept of MATISSE including a description of the signal on the detectors and an evaluation of the expected performances. We also discuss the current status of the MATISSE instrument, which is entering its testing phase, and the foreseen schedule for the next two years that will lead to the first light at Paranal.Comment: SPIE Astronomical Telescopes and Instrumentation conference, June 2016, 11 pages, 6 Figure

    Configuration of readout electronics and data acquisition for the HiPERCAM instrument

    Get PDF
    © 2018 SPIE. HiPERCAM is a five channel fast photometer to study high temporal variability of the universe, covering from 0.3 to 1.0 microns in five wavebands. HiPERCAM uses custom-made 2Kx1K split-frame transfer CCDs mounted in separate compact camera heads and cooled by thermoelectric coolers to 180K. The demands on the readout system are very unique to this instrument in that all five CCDs are operated in a pseudo drift window mode along with the normal windowing, binning and full-frame modes. The pseudo drift mode involves reading out small window regions from 2 quadrants of each CCD, with the possibility to exceed 1 kHz window rates per output channel. The CCDs are custom manufactured by Teledyne e2v to allow independent serial clock controls for each output. The devices are manufactured in standard and deep-depletion processes with appropriate anti-reflection coatings to achieve high quantum efficiencies in each of the five wavebands. An ESO NGC controller has been configured to control and readout all five CCDs. The data acquisition software has been modified to provide GPS timestamping of the data and access to the acquired data in real time for the data reduction software. The instrument has had its first light and first science observations on the 4.2m William Herschel Telescope, La Palma during a commissioning run in October 2017 and subsequently on the 10.4m Gran Telescopio Canarias in February 2018 and science observations in April 2018. This paper will present the details of the preamplifier electronics, configuration of the readout electronics and the data acquisition software to support the unique readout modes along with the overall performance of the instrument

    First light for GRAVITY: Phase referencing optical interferometry for the Very Large Telescope Interferometer

    Get PDF
    This is the author accepted manuscript. the final version is available from EDP Sciences via the DOI in this recordGRAVITY is a new instrument to coherently combine the light of the European Southern Observatory Very Large Telescope Interferometer to form a telescope with an equivalent 130 m diameter angular resolution and a collecting area of 200 m2. The instrument comprises fiber fed integrated optics beam combination, high resolution spectroscopy, built-in beam analysis and control, near-infrared wavefront sensing, phase-tracking, dual-beam operation, and laser metrology. GRAVITY opens up to optical/infrared interferometry the techniques of phase referenced imaging and narrow angle astrometry, in many aspects following the concepts of radio interferometry. This article gives an overview of GRAVITY and reports on the performance and the first astronomical observations during commissioning in 2015/16. We demonstrate phase-tracking on stars as faint as mK ≈ 10 mag, phase-referenced interferometry of objects fainter than mK ≈ 15 mag with a limiting magnitude of mK ≈ 17 mag, minute long coherent integrations, a visibility accuracy of better than 0.25%, and spectro-differential phase and closure phase accuracy better than 0.5°, corresponding to a differential astrometric precision of better than ten microarcseconds (μas). The dual-beam astrometry, measuring the phase difference of two objects with laser metrology, is still under commissioning. First observations show residuals as low as 50 μas when following objects over several months. We illustrate the instrument performance with the observations of archetypical objects for the different instrument modes. Examples include the Galactic center supermassive black hole and its fast orbiting star S2 for phase referenced dual-beam observations and infrared wavefront sensing, the high mass X-ray binary BP Cru and the active galactic nucleus of PDS 456 for a few μas spectro-differential astrometry, the T Tauri star S CrA for a spectro-differential visibility analysis, ξ Tel and 24 Cap for high accuracy visibility observations, and η Car for interferometric imaging with GRAVITY.Agence Nationale de la RechercheAlexander von Humboldt FoundationEuropean Union, Seventh Framework Programm

    Multiple star systems in the Orion nebula

    Get PDF
    This is the author accepted manuscript. The final fersion is available from EDP Sciences via the DOI in this record.This work presents an interferometric study of the massive-binary fraction in the Orion Trapezium cluster with the recently comissioned GRAVITY instrument. We observed a total of 16 stars of mainly OB spectral type. We find three previously unknown companions for θ1 Ori B, θ2 Ori B, and θ2 Ori C. We determined a separation for the previously suspected companion of NU Ori. We confirm four companions for θ1 Ori A, θ1 Ori C, θ1 Ori D, and θ2 Ori A, all with substantially improved astrometry and photometric mass estimates. We refined the orbit of the eccentric high-mass binary θ1 Ori C and we are able to derive a new orbit for θ1 Ori D. We find a system mass of 21.7 M⊙ and a period of 53 days. Together with other previously detected companions seen in spectroscopy or direct imaging, eleven of the 16 high-mass stars are multiple systems. We obtain a total number of 22 companions with separations up to 600 AU. The companion fraction of the early B and O stars in our sample is about two, significantly higher than in earlier studies of mostly OB associations. The separation distribution hints toward a bimodality. Such a bimodality has been previously found in A stars, but rarely in OB binaries, which up to this point have been assumed to be mostly compact with a tail of wider companions. We also do not find a substantial population of equal-mass binaries. The observed distribution of mass ratios declines steeply with mass, and like the direct star counts, indicates that our companions follow a standard power law initial mass function. Again, this is in contrast to earlier findings of flat mass ratio distributions in OB associations. We excluded collision as a dominant formation mechanism but find no clear preference for core accretion or competitive accretion.Marie Skłodowska-Curie Grant AgreementFCT-PortugalERC Starting Gran

    The Return of the Mid-infrared to the VLT: News from the VISIR Upgrade

    Get PDF
    The VLT mid-infrared imager and spectrometer VISIR returns to science operations following an extended upgrade period. Among the most important modifications are: the imaging and spectroscopic detectors have been replaced with larger AQUARIUS (1024 by 1024 pixel) detector arrays; the N-band low-resolution grating has been exchanged; and support is now provided for precipitable water vapour monitoring, in order to select the best observing conditions. The AQUARIUS detectors stem from a development for very low background applications which result in excess noise under ground-based conditions. A series of interventions was needed to find a scheme that effectively exploits these detectors for ground-based use, involving the implementation of faster chopping. VISIR has been returned to service at the VLT with enhanced capabilities

    HARMONI at ELT: overview of the capabilities and expected performance of the ELT's first light, adaptive optics assisted integral field spectrograph.

    Get PDF

    First light for GRAVITY: Phase referencing optical interferometry for the Very Large Telescope Interferometer

    Full text link

    Mid-infrared circumstellar emission of the long-period Cepheid l Carinae resolved with VLTI/MATISSE

    Get PDF
    Stars and planetary system
    corecore