250 research outputs found

    Cutting forces and wear analysis of Si3N4 diamond coated tools in high speed machining

    Get PDF
    Si3N4 tools were coated with a thin diamond film using a Hot-Filament Chemical Vapour Deposition (HFCVD) reactor, in order to machining a grey cast iron. Wear behaviour of these tools in high speed machining was the main subject of this work. Turning tests were performed with a combination of cutting speeds of 500, 700 and 900 m min−1, and feed rates of 0.1, 0.25 and 0.4 mm rot−1, remaining constant the depth of cut of 1 mm. In order to evaluate the tool behaviour during the turning tests, cutting forces were analyzed being verified a significant increase with feed rate. Diamond film removal occurred for the most severe set of cutting parameters. It was also observed the adhesion of iron and manganese from the workpiece to the tool. Tests were performed on a CNC lathe provided with a 3-axis dynamometer. Results were collected and registered by homemade software. Tool wear analysis was achieved by a Scanning Electron Microscope (SEM) provided with an X-ray Energy Dispersive Spectroscopy (EDS) system. Surface analysis was performed by a profilometer

    Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements

    Get PDF
    The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM) dynamometric measurements for maximum and average strengths, as well as endurance. A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9) participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC) was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. The intra and inter-raters' analyses showed good reliability for maximum strength (ICCintra-rater1=0.96, ICCintra-rater2=0.95, and ICCinter-rater=0.96), average strength (ICCintra-rater1=0.96, ICCintra-rater2=0.94, and ICCinter-rater=0.97), and endurance (ICCintra-rater1=0.88, ICCintra-rater2=0.86, and ICCinter-rater=0.92) dynamometric measurements. The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice.1929710

    Role of abrasive material on micro-abrasion wear tests

    Get PDF
    Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution

    a quantitative approach

    Get PDF
    publishersversionpublishe

    Environmental risk assessment in a contaminated estuary: an integrated weight of evidence approach as a decision support tool

    Get PDF
    Environmental risk assessment of complex ecosystems such as estuaries is a challenge, where innovative and integrated approaches are needed. The present work aimed at developing an innovative integrative methodology to evaluate in an impacted estuary (the Sado, in Portugal, was taken as case study), the adverse effects onto both ecosystem and human health. For the purpose, new standardized lines of evidence based on multiple quantitative data were integrated into a weight of evidence according to a best expert judgment approach. The best professional judgment for a weight of evidence approach in the present study was based on the following lines of evidence: i) human contamination pathways; ii) human health effects: chronic disease; iii) human health effects: reproductive health; iv) human health effects: health care; v) human exposure through consumption of local agriculture produce; vi) exposure to contaminated of water wells and agriculture soils; vii) contamination of the estuarine sedimentary environment (metal and organic contaminants); viii) effects on benthic organisms with commercial value; and ix) genotoxic potential of sediments. Each line of evidence was then ordinally ranked by levels of ecological or human health risk, according to a tabular decision matrix and expert judgment. Fifteen experts scored two fishing areas of the Sado estuary and a control estuarine area, in a scale of increasing environmental risk and management actions to be taken. The integrated assessment allowed concluding that the estuary should not be regarded as impacted by a specific toxicant, such as metals and organic compounds hitherto measured, but by the cumulative risk of a complex mixture of contaminants. The proven adverse effects on species with commercial value may be used to witness the environmental quality of the estuarine ecosystem. This method argues in favor of expert judgment and qualitative assessment as a decision support tool to the integrative management of estuaries. Namely it allows communicating environmental risk and proposing mitigation measures to local authorities and population under a holistic perspective as an alternative to narrow single line of evidence approaches, which is mandatory to understand cause and effect relationships in complex areas like estuaries.info:eu-repo/semantics/publishedVersio

    Absence of the spindle assembly checkpoint restores mitotic fidelity upon loss of sister chromatid cohesion

    Get PDF
    The fidelity of mitosis depends on cohesive forces that keep sister chromatids together. This is mediated by cohesin that embraces sister chromatid fibers from the time of their replication until the subsequent mitosis [1-3]. Cleavage of cohesin marks anaphase onset, where single chromatids are dragged to the poles by the mitotic spindle [4-6]. Cohesin cleavage should only occur when all chromosomes are properly bio-oriented to ensure equal genome distribution and prevent random chromosome segregation. Unscheduled loss of sister chromatid cohesion is prevented by a safeguard mechanism known as the spindle assembly checkpoint (SAC) [7, 8]. To identify specific conditions capable of restoring defects associated with cohesion loss, we screened for genes whose depletion modulates Drosophila wing development when sister chromatid cohesion is impaired. Cohesion deficiency was induced by knockdown of the acetyltransferase separation anxiety (San)/Naa50, a cohesin complex stabilizer [9-12]. Several genes whose function impacts wing development upon cohesion loss were identified. Surprisingly, knockdown of key SAC proteins, Mad2 and Mpsl, suppressed developmental defects associated with San depletion. SAC impairment upon cohesin removal, triggered by San depletion or artificial removal of the cohesin complex, prevented extensive genome shuffling, reduced segregation defects, and restored cell survival. This counterintuitive phenotypic suppression was caused by an intrinsic bias for efficient chromosome biorientation at mitotic entry, coupled with slow engagement of error-correction reactions. Thus, in contrast to SAC's role as a safeguard mechanism for mitotic fidelity, removal of this checkpoint alleviates mitotic errors when sister chromatid cohesion is compromised.Lisboa Regional Operational Programme (Lisboa 2020) through the European Regional Development Fund (FEDER); Fundacao para a Ciencia e a Tecnologia (FCT; Portugal); FCT [SFRH/BPD/87482/2012, SFRH /BD/52438/2013, PD/BD/52428/2013, PD/00117/2012, CRM: 0027030, PTDC/BEX-BID/0395/2014, UID/BIM/04773/2013 CBMR 1334, IF/00851/2012/CP0185/CT0004]; Association for International Cancer Research [AICR 10-0553]; EMBO Installation Grant [IG2778]; European Research Council Starting Grant [ERC-2014-STG-638917]; [PPBI-POCI-01-0145-FEDER-022122]; [LISBOA-01-0145-FEDER-022170

    Tolerogenic versus Inflammatory Activity of Peripheral Blood Monocytes and Dendritic Cells Subpopulations in Systemic Lupus Erythematosus

    Get PDF
    Abnormalities in monocytes and in peripheral blood dendritic cells (DC) subsets have been reported in systemic lupus erythematosus (SLE). We aim to clarify the tolerogenic or inflammatory role of these cells based on ICOSL or IFN-α and chemokine mRNA expression, respectively, after cell purification. The study included 18 SLE patients with active disease (ASLE), 25 with inactive disease (ISLE), and 30 healthy controls (HG). In purified plasmacytoid DC (pDC) was observed a lower ICOSL mRNA expression in ASLE and an increase in ISLE; similarly, a lower ICOSL mRNA expression in monocytes of ALSE patients was found. However, a higher ICOSL mRNA expression was observed in ASLE compared to HG in myeloid DCs. Interestingly, clinical parameters seem to be related with ICOSL mRNA expression. Regarding the inflammatory activity it was observed in purified monocytes and CD14(-/low) CD16(+) DCs an increase of CCL2, CXCL9, and CXCL10 mRNA expression in ASLE compared to HG. In myeloid DC no differences were observed regarding chemokines, and IFN-α mRNA expression. In pDC, a higher IFN-α mRNA expression was observed in ASLE. Deviations in ICOSL, chemokine, and IFN-α mRNA expression in peripheral blood monocytes and dendritic cells subpopulations in SLE appear to be related to disease activity

    An SNF2 helicase-like protein links mitotic transcription termination to sister chromatid resolution

    Get PDF
    Mitotic chromatin is largely assumed incompatible with transcription due to changes in the transcription machinery and chromosome architecture. However, the mechanisms of mitotic transcriptional inactivation and their interplay with chromosome assembly remain largely unknown. By monitoring ongoing transcription in Drosophila early embryos, we reveal that eviction of nascent mRNAs from mitotic chromatin occurs after substantial chromosome compaction and is not promoted by condensin I. Instead, we show that the timely removal of transcripts from mitotic chromatin is driven by the SNF2 helicase-like protein Lodestar (Lds), identified here as a modulator of sister chromatid cohesion defects. In addition to transcriptional termination, we uncovered that Lds cooperates with Topoisomerase 2 to ensure efficient sister chromatid resolution and mitotic fidelity. We conclude that mitotic transcriptional termination is not a passive consequence of cell cycle progression and/or chromosome compaction but occurs via dedicated mechanisms with functional parallelisms to sister chromatid resolution.info:eu-repo/semantics/publishedVersio

    Micro-abrasion wear behaviour of TiAlCrSiN nanostructured coatings

    Get PDF
    The injection process of glass fibres reinforced plastics promotes the moulds surface degradation by erosion. In order to improve its wear resistance, several kinds of PVD thin hard coatings were used. It is well-known that nanostructures present a better compromise between hardness and toughness. Indeed, when the coating is constituted by a large number of ultra-thin different layers, cracks and interface troubles tend to decrease. However, it is not clear that these nanostructures present a better wear behaviour in erosion processes. In order to study its wear behaviour, a sputtered PVD nanostructured TiAlCrSiN coating was used. The substrate and film surfaces topography were analyzed by profilometry and atomic force microscopy techniques. Film adhesion to the substrate was evaluated by scratch tests. The surface hardness was measured with a Vickers micro-hardness tester. The wear resistance was evaluated by micro-abrasion with a rotating ball tribometer tests. Slurry of SiC particles in distilled water was used in order to provoke the surface abrasion. Different duration tests were performed in order to analyze the wear evolution. After these tests, the wear mechanisms developed were analyzed by scanning electron microscopy. Wear craters were measured and the wear rate was calculated and discussed. With the same purpose, coated inserts were mounted in an injection mould working with a 30% glass fibres reinforced polypropylene. After 45 000 cycles no relevant wear was registered
    corecore