19 research outputs found
Dinamica estocastica clĂĄsica y cuĂĄntica de la difusiĂłn activada de adsorbatos interactuantes en superficies
Tesis doctoral inĂ©dita. Universidad AutĂłnoma de Madrid, Facultad de Ciencias, Departamento de FĂsica TeĂłrica de la Materia Condensada. Fecha de lectura: 19-06-0
Ethanol gas sensing mechanisms of p-type NiO at room temperature
Conductometric gas sensors based on metal oxide semiconductors (MOS) usually require high temperature operation, increasing their energy consumption and limiting their applicability. However, room temperature operation with these devices still remains a challenge in many sensor-analyte systems due in part to the low or null response and recovery speeds obtained at this temperature. In this work, the conductometric response of p-type NiO ceramic samples to ethanol is studied under room temperature operation. An anomalous response consisting in an unexpected resistance decrease upon ethanol exposure is observed depending on sample texturing, which is tuned by changing the temperature at which the samples are synthesized. This anomalous response is characterized by fast response and recovery times. A model based on two competing mechanisms, consisting in either an electron transfer from NiO to the ethanol molecule or the catalytic decomposition of adsorbed ethanol, is proposed to explain the observed anomalous response. Extending this model to other MOS could pave the way for fast sensors operating at room temperatur
Assessing aids for the elaboration of argumentative synthesis in the University: Guide or Rubric?
Although most of the interventions to foster the integration of multiple pieces of information has focused on teaching âhowâ to integrate (Barzilai et al., 2018) providing different kinds of instruction on the processes implied, instruction focusing on the criteria to evaluate integration are scarce and mainly centered on integrating complementary, but not contradictory, sources.
In this work we designed and contrasted the effectiveness of two aids to improve the quality of the syntheses written by undergraduates from texts that defended opposing views on a topic: a Guide to the process of preparing a synthesis vs a Rubric with the evaluation criteria of written products. The number of arguments and the degree of integration were examined. Also, the students' perception was assessed regarding the usefulness of the aids to plan, to write and to review their synthesis.
Seen that we found that offering a guide accompanied by explicit instruction is more effective than providing it without explicit instruction Mateos et al. (2018), the two aids were offered here under two conditions: Explicit Instruction vs. Traditional Instruction. Thus, we carried out an experimental study with 122 Psychology students, distributed randomly into four intervention programs. In the first and fourth session they performed a synthesis task without support. In the second session, after receiving the instruction (explicit vs. traditional), each student made a new synthesis using the specific aid provided (practice 1, with Guide/Rubric). In the third session the participants carried out another synthesis under analogous conditions (practice 2, with aids).
Our results pointed out that, regardless the instruction, both aids (Guide and Rubric) improved the degree of integration of the studentsâ syntheses. However, the guide contributed better to improve the selection of arguments. Students who received Explicit Instruction found both aids to be equally useful for planning and writing their syntheses. In contrast, after Traditional Instruction the Guide was perceived as more useful for planning and writing syntheses. The Guide was more useful for reviewing their texts. We will discuss the implications of these findings for synthesis writing training and conclude with recommendations and suggestions for future studies.2021-2
Influence of cation substitution on the complex structure and luminescent properties of the Zn_kIn_2O_(k+3) system
The effect of In^(3+) substitution by Ga^(3+) or Al^(3+) on the structure and luminescent properties of Zn_7In_(2-x)M_xO_10 (M = Ga or Al; 0 <= x <= 1) oxides has been investigated by means of high spatial resolution X-ray spectroscopy and high-angle annular dark-field images, combined with magic angle spinning nuclear magnetic resonance spectroscopy. Local structural variations have been identified for the Al- and Ga-doped samples through the analysis of atomically resolved chemical maps and the identification of their structural environment within the wurtzite lattice. In3+ is distributed in a zig-zag modulation, while Al^(3+) and Ga^(3+) are located in a flat distribution at the center of the wurtzite block. Density functional theory calculations provide unambiguous evidence for the preferential flat location of Ga^(3+) and Al^(3+) associated with the different strains introduced in the structure as a result of their ionic radii. The characterization of the photoluminescence response reveals the appearance of new radiative recombination pathways for the doped materials because of the presence of new defect levels in the band gap of the Zn_7In_2O_10 structure
Correlation of RECIST, Computed Tomography Morphological Response, and Pathological Regression in Hepatic Metastasis Secondary to Colorectal Cancer: The AVAMET Study.
Background: The prospective phase IV AVAMET study was undertaken to correlate response evaluation criteria in solid tumors (RECIST)-defined response rates with computed tomography-based morphological criteria (CTMC) and pathological response after liver resection of colorectal cancer metastases. Methods: Eligible patients were aged >/=18 years, with Eastern Cooperative Oncology Group (ECOG) performance status 0/1 and histologically-confirmed colon or rectal adenocarcinoma with measurable liver metastases. Preoperative treatment was bevacizumab (7.5 mg on day 1) + XELOX (oxaliplatin 130 mg/m(2), capecitabine 1000 mg/m(2) bid on days 1-14 q3w). After three cycles, response was evaluated by a multidisciplinary team. Patients who were progression-free and metastasectomy candidates received one cycle of XELOX before undergoing surgery 3-5 weeks later, followed by four cycles of bevacizumab + XELOX. Results: A total of 83 patients entered the study; 68 were eligible for RECIST, 67 for CTMC, and 51 for pathological response evaluation. Of these patients, 49% had a complete or partial RECIST response, 91% had an optimal or incomplete CTMC response, and 81% had a complete or major pathological response. CTMC response predicted 37 of 41 pathological responses versus 23 of 41 responses predicted using RECIST (p = 0.008). Kappa coefficients indicated a lack of correlation between the results of RECIST and morphological responses and between morphological and pathological response rates. Conclusion: CTMC may represent a better marker of pathological response to bevacizumab + XELOX than RECIST in patients with potentially-resectable CRC liver metastases
patrimonio intelectual
Actas de congresoLas VI Jornadas se realizaron con la exposiciĂłn de ponencias que se incluyeron en cuatro ejes temĂĄticos, que se desarrollaron de modo sucesivo para facilitar la asistencia, el intercambio y el debate, distribuidos en tres jornadas.
Los ejes temĂĄticos abordados fueron:
1. La enseñanza como proyecto de investigación. Recursos de enseñanza-aprendizaje como mejoras de la calidad educativa.
2. La experimentación como proyecto de investigación. Del ensayo a la aplicabilidad territorial, urbana, arquitectónica y de diseño industrial.
3. Tiempo y espacio como proyecto de investigaciĂłn. Sentido, destino y usos del patrimonio construido y simbĂłlico.
4. Idea constructiva, formulaciĂłn y ejecuciĂłn como proyecto de investigaciĂłn. BĂșsqueda y elaboraciĂłn de resultados que conforman los proyectos de la arquitectura y el diseño
Mortality from gastrointestinal congenital anomalies at 264 hospitals in 74 low-income, middle-income, and high-income countries: a multicentre, international, prospective cohort study
Summary
Background Congenital anomalies are the fifth leading cause of mortality in children younger than 5 years globally.
Many gastrointestinal congenital anomalies are fatal without timely access to neonatal surgical care, but few studies
have been done on these conditions in low-income and middle-income countries (LMICs). We compared outcomes of
the seven most common gastrointestinal congenital anomalies in low-income, middle-income, and high-income
countries globally, and identified factors associated with mortality.
Methods We did a multicentre, international prospective cohort study of patients younger than 16 years, presenting to
hospital for the first time with oesophageal atresia, congenital diaphragmatic hernia, intestinal atresia, gastroschisis,
exomphalos, anorectal malformation, and Hirschsprungâs disease. Recruitment was of consecutive patients for a
minimum of 1 month between October, 2018, and April, 2019. We collected data on patient demographics, clinical
status, interventions, and outcomes using the REDCap platform. Patients were followed up for 30 days after primary
intervention, or 30 days after admission if they did not receive an intervention. The primary outcome was all-cause,
in-hospital mortality for all conditions combined and each condition individually, stratified by country income status.
We did a complete case analysis.
Findings We included 3849 patients with 3975 study conditions (560 with oesophageal atresia, 448 with congenital
diaphragmatic hernia, 681 with intestinal atresia, 453 with gastroschisis, 325 with exomphalos, 991 with anorectal
malformation, and 517 with Hirschsprungâs disease) from 264 hospitals (89 in high-income countries, 166 in middleincome
countries, and nine in low-income countries) in 74 countries. Of the 3849 patients, 2231 (58·0%) were male.
Median gestational age at birth was 38 weeks (IQR 36â39) and median bodyweight at presentation was 2·8 kg (2·3â3·3).
Mortality among all patients was 37 (39·8%) of 93 in low-income countries, 583 (20·4%) of 2860 in middle-income
countries, and 50 (5·6%) of 896 in high-income countries (p<0·0001 between all country income groups).
Gastroschisis had the greatest difference in mortality between country income strata (nine [90·0%] of ten in lowincome
countries, 97 [31·9%] of 304 in middle-income countries, and two [1·4%] of 139 in high-income countries;
pâ€0·0001 between all country income groups). Factors significantly associated with higher mortality for all patients
combined included country income status (low-income vs high-income countries, risk ratio 2·78 [95% CI 1·88â4·11],
p<0·0001; middle-income vs high-income countries, 2·11 [1·59â2·79], p<0·0001), sepsis at presentation (1·20
[1·04â1·40], p=0·016), higher American Society of Anesthesiologists (ASA) score at primary intervention
(ASA 4â5 vs ASA 1â2, 1·82 [1·40â2·35], p<0·0001; ASA 3 vs ASA 1â2, 1·58, [1·30â1·92], p<0·0001]), surgical safety
checklist not used (1·39 [1·02â1·90], p=0·035), and ventilation or parenteral nutrition unavailable when needed
(ventilation 1·96, [1·41â2·71], p=0·0001; parenteral nutrition 1·35, [1·05â1·74], p=0·018). Administration of
parenteral nutrition (0·61, [0·47â0·79], p=0·0002) and use of a peripherally inserted central catheter (0·65
[0·50â0·86], p=0·0024) or percutaneous central line (0·69 [0·48â1·00], p=0·049) were associated with lower mortality.
Interpretation Unacceptable differences in mortality exist for gastrointestinal congenital anomalies between lowincome,
middle-income, and high-income countries. Improving access to quality neonatal surgical care in LMICs will
be vital to achieve Sustainable Development Goal 3.2 of ending preventable deaths in neonates and children younger
than 5 years by 2030
Ethanol gas sensing mechanisms of p-type NiO at room temperature
CRUE-CSIC (Acuerdos Transformativos 2021)
© 2021 The Authors.
This work was supported by the V-PRICIT of Comunidad de Madrid through the research project PR65/19-22335 and by the RTI2018-097195-B-I00 project supported by MCI/AEI/FEDER, UE. Authors thank the ESCA-microscopy staff at the Elettra Synchrotron for their help during XPS and additional sensitivity measurements. J.B. acknowledges financial support from the Comunidad de Madrid through the Talento fellowship 2017-T2/IND-5617.Conductometric gas sensors based on metal oxide semiconductors (MOS) usually require high temperature operation, increasing their energy consumption and limiting their applicability. However, room temperature operation with these devices still remains a challenge in many sensor-analyte systems due in part to the low or null response and recovery speeds obtained at this temperature. In this work, the conductometric response of ptype NiO ceramic samples to ethanol is studied under room temperature operation. An anomalous response consisting in an unexpected resistance decrease upon ethanol exposure is observed depending on sample texturing, which is tuned by changing the temperature at which the samples are synthesized. This anomalous response is characterized by fast response and recovery times. A model based on two competing mechanisms, consisting in either an electron transfer from NiO to the ethanol molecule or the catalytic decomposition of adsorbed ethanol, is proposed to explain the observed anomalous response. Extending this model to other MOS could pave the way for fast sensors operating at room temperature.Ministerio de Ciencia e InnovaciĂłn (MICINN)/FEDERComunidad de MadridDepto. de FĂsica de MaterialesFac. de Ciencias FĂsicasTRUEpu
Ethanol gas sensing mechanisms of p-type NiO at room temperature
Conductometric gas sensors based on metal oxide semiconductors (MOS) usually require high temperature operation, increasing their energy consumption and limiting their applicability. However, room temperature operation with these devices still remains a challenge in many sensor-analyte systems due in part to the low or null response and recovery speeds obtained at this temperature. In this work, the conductometric response of ptype NiO ceramic samples to ethanol is studied under room temperature operation. An anomalous response consisting in an unexpected resistance decrease upon ethanol exposure is observed depending on sample texturing, which is tuned by changing the temperature at which the samples are synthesized. This anomalous response is characterized by fast response and recovery times. A model based on two competing mechanisms, consisting in either an electron transfer from NiO to the ethanol molecule or the catalytic decomposition of adsorbed ethanol, is proposed to explain the observed anomalous response. Extending this model to other MOS could pave the way for fast sensors operating at room temperature
Li-doping effects on the native defects and luminescence of Zn2GeO4 microstructures: Negative thermal quenching
El texto completo de este trabajo no se encuentra disponible por no haber sido facilitado aĂșn por su autor, por restricciones de copyright, o por no existir una versiĂłn digitalNovel transparent semiconducting oxides have emerged as key materials for a variety of optoelectronic applications due to their ultra-wide band gap. Owing to the critical role of native defects and impurities in the optoelectronical properties, investigation in detail of the electronic structure of these oxides has become a challenge, being luminescence technique a powerful way to gain insight into the electronic levels. Here, the photoluminescence temperature dependence of Li doped Zn2GeO4 microrods is analysed and discussed in the framework of the electronic levels structure related to native defects and Li impurities. Unlike the undoped material, the blue emission (2.8 eV) of Li-doped germanate exhibits a negative thermal quenching as its photoluminescence intensity increases with increasing temperature. The mechanisms underlying this anomalous behaviour are discussed with the aid of X-ray photoemission spectroscopy and first principles calculations. This study has helped us to understand the role of Li in the electronic structure and optical response of Zn2GeO4. Our results highlight the versatility of Zn2GeO4 luminescence through Li doping, which could be exploited in optoelectronic devices with bespoke properties.Ministerio de Ciencia e InnovaciĂłn (España)Depto. de FĂsica de MaterialesFac. de Ciencias FĂsicasTRUEpu