607 research outputs found

    Vibration Analysis of a Low-Power Reduction Gear

    No full text
    Free vibrations of a low-power reduction gear engaged with a hydraulic pump of the test rig are discussed. Vibration analysis is performed with the finite element representation and commercial ANSYS program. Vibration analysis of an examined system is conducted in the two stages. The natural frequencies of free transverse vibrations of the gears are first generated, and on the basis of the Campbell diagrams, the excitation speeds for several natural frequencies of examined gears are calculated. Then the free vibrations of a reduction gear are analyzed, and two computational cases are presented. In the first case, only the mass and geometry of all parts of the body are considered. In the second case, the mass of tooth gears is also taken into account. Based on the FE models, the first ten natural frequencies and natural mode shapes of a reduction gear are calculated. Then, these results are used to estimate the stress level in the walls of the body for a permissible acceleration value. As expected, smaller stress values for a permissible acceleration value are obtained for the second finite element model of the system. The problems discussed here can be helpful for engineers dealing with the dynamics of gear systems

    Altered operant responding for motor reinforcement and the determination of benchmark doses following perinatal exposure to low-level 2,3,7,8-tetrachlorodibenzo-p-dioxin.

    Get PDF
    Pregnant Holtzman rats were exposed to a single oral dose of 0, 20, 60, or 180 ng/kg 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) on the 18th day of gestation. Their adult female offspring were trained to respond on a lever for brief opportunities to run in specially designed running wheels. Once they had begun responding on a fixed-ratio 1 (FR1) schedule of reinforcement, the fixed-ratio requirement for lever pressing was increased at five-session intervals to values of FR2, FR5, FR10, FR20, and FR30. We examined vaginal cytology after each behavior session to track estrous cyclicity. Under each of the FR values, perinatal TCDD exposure produced a significant dose-related reduction in the number of earned opportunities to run, the lever response rate, and the total number of revolutions in the wheel. Estrous cyclicity was not affected. Because of the consistent dose-response relationship at all FR values, we used the behavioral data to calculate benchmark doses based on displacements from modeled zero-dose performance of 1% (ED(01)) and 10% (ED(10)), as determined by a quadratic fit to the dose-response function. The mean ED(10) benchmark dose for earned run opportunities was 10.13 ng/kg with a 95% lower bound of 5.77 ng/kg. The corresponding ED(01) was 0.98 ng/kg with a 95% lower bound of 0.83 ng/kg. The mean ED(10) for total wheel revolutions was calculated as 7.32 ng/kg with a 95% lower bound of 5.41 ng/kg. The corresponding ED(01) was 0.71 ng/kg with a 95% lower bound of 0.60. These values should be viewed from the perspective of current human body burdens, whose average value, based on TCDD toxic equivalents, has been calculated as 13 ng/kg

    The effects of salinity and temperature on the development and survival of fish parasites

    Get PDF
    In brackish water the variety of marine and freshwater parasite species is considerably reduced. The distribution in brackish water of most marine endoparasites is restricted by the salinity tolerance of their hosts, most of the parasite species are more tolerant than their hosts. The influence of salinity and temperature on nine species has been examined; first stage larvae of Contracaecum aduncum develop in 0-32‰ salinity; Cryptocotyle lingua proved to be infective at salinities down to 4‰. The greatest resistance was found in Anisakis larvae from herring Clupea harengus, which survived for more than half a year. Parasites in the fish intestines appear to be unaffected by changing water salinities, as the osmolarity in the intestines stays nearly constant. Marine ectoparasites (Acanthochondria depressa, Lepeophtheirus pectoralis) survive about three times longer than freshwater species (Piscicola geometra, Argulus foliaceus) when salinity is 16‰. High temperature increases the effects of adverse salinities on parasites. There is evidence that none of these ecto-parasitic species can develop within the range of 7-20‰ salinity

    Cold‐pool‐driven convective initiation: using causal graph analysis to determine what convection‐permitting models are missing

    Get PDF
    Cold‐pool‐driven convective initiation is investigated in high‐resolution, convection‐permitting simulations with a focus on the diurnal cycle and organization of convection and the sensitivity to grid size. Simulations of four different days over Germany were performed using the ICON‐LEM model with grid sizes from 156 to 625 m. In these simulations, we identify cold pools, cold‐pool boundaries and initiated convection. Convection is triggered much more efficiently in the vicinity of cold pools than in other regions and can provide as much as 50% of total convective initiation, in particular in the late afternoon. By comparing different model resolutions, we find that cold pools are more frequent, smaller and less intense in lower‐resolution simulations. Furthermore, their gust fronts are weaker and less likely to trigger new convection. To identify how model resolution affects this triggering probability, we use a linear causal graph analysis. In doing so, we postulate a graph structure with potential causal pathways and then apply multi‐linear regression accordingly. We find a dominant, systematic effect: reducing grid sizes directly reduces upward mass flux at the gust front, which causes weaker triggering probabilities. These findings are expected to be even more relevant for km‐scale, numerical weather prediction models. We thus expect that a better representation of cold‐pool‐driven convective initiation will improve forecasts of convective precipitation

    Role of immunohistochemistry for interobserver agreement of Peritoneal Regression Grading Score in peritoneal metastasis.

    Get PDF
    Pressurized intraperitoneal aerosol chemotherapy (PIPAC)-directed therapy is a new treatment option for peritoneal metastasis (PM). The 4-tiered Peritoneal Regression Grading Score (PRGS) has been proposed for assessment of histological treatment response. We aimed to evaluate the effect of immunohistochemistry (IHC) on interobserver agreement of the PRGS. Hematoxylin and eosin (H&E)-stained and IHC-stained slides (n = 662) from 331 peritoneal quadrant biopsies (QBs) taken prior to 99 PIPAC procedures performed on 33 patients were digitalized and uploaded to a web library. Eight raters (five consultants and three residents) assessed the PRGS, and Krippendorff's alpha coefficients (α) were calculated. Results (IHC-PRGS) were compared with data published in 2019, using H&E-stained slides only (H&E-PRGS). Overall, agreement for IHC-PRGS was substantial to almost perfect. Agreement (all raters) regarding single QBs after treatment was substantial for IHC-PRGS (α = 0.69, 95% confidence interval [CI] = 0.66-0.72) and moderate for H&E-PRGS (α = 0.60, 95% CI = 0.56-0.64). Agreement (all raters) regarding the mean PRGS per QB set after treatment was higher for IHC-PRGS (α = 0.78, 95% CI = 0.73-0.83) than for H&E-PRGS (α = 0.71, 95% CI = 0.64-0.78). Among residents, agreement was almost perfect for IHC-PRGS and substantial for H&E-PRGS. Agreement (all raters) regarding maximum PRGS per QB set after treatment was substantial for IHC-PRGS (α = 0.61, 95% CI = 0.54-0.68) and moderate for H&E-PRGS (α = 0.60, 95% CI = 0.53-0.66). Among residents, agreement was substantial for IHC-PRGS (α = 0.66, 95% CI = 0.57-0.75) and moderate for H&E-PRGS (α = 0.55, 95% CI = 0.45-0.64). Additional IHC seems to improve the interobserver agreement of PRGS, particularly between less experienced raters

    Screening of antioxidant properties of the apple juice using the front-face synchronous fluorescence and chemometrics

    Get PDF
    Fluorescence spectroscopy is gaining increasing attention in food analysis due to its higher sensitivity and selectivity as compared to other spectroscopic techniques. Synchronous scanning fluorescence technique is particularly useful in studies of multi-fluorophoric food samples, providing a further improvement of selectivity by reduction in the spectral overlapping and suppressing light-scattering interferences. Presently, we study the feasibility of the prediction of the total phenolics, flavonoids, and antioxidant capacity using front-face synchronous fluorescence spectra of apple juices. Commercial apple juices from different product ranges were studied. Principal component analysis (PCA) applied to the unfolded synchronous fluorescence spectra was used to compare the fluorescence of the entire sample set. The regression analysis was performed using partial least squares (PLS1 and PLS2) methods on the unfolded total synchronous and on the single-offset synchronous fluorescence spectra. The best calibration models for all of the studied parameters were obtained using the PLS1 method for the single-offset synchronous spectra. The models for the prediction of the total flavonoid content had the best performance; the optimal model was obtained for the analysis of the synchronous fluorescence spectra at Delta lambda = 110 nm (R (2) = 0.870, residual predictive deviation (RPD) = 2.7). The optimal calibration models for the prediction of the total phenolic content (Delta lambda = 80 nm, R (2) = 0.766, RPD = 2.0) and the total antioxidant capacity (Delta lambda = 70 nm, R (2) = 0.787, RPD = 2.1) had only an approximate predictive ability. These results demonstrate that synchronous fluorescence could be a useful tool in fast semi-quantitative screening for the antioxidant properties of the apple juices.info:eu-repo/semantics/publishedVersio
    corecore