462 research outputs found

    Corticosteroid Weaning in Stable Heart Transplant Patients: Guidance by Serum Cortisol Level

    Get PDF
    Background: Despite earlier studies describing the feasibility of steroid weaning in heart transplant patients, the majority of patients are maintained on steroid therapy for life. We examined a strategy based on a single morning serum cortisol measurement. Methods: We assigned stable posttransplant patients, who were maintained on tacrolimus, mycophenolate mofetil, and corticosteroids, into one of two groups based on a screening morning cortisol level. Patients with a cortisol \u3c 8 micrograms/deciliter were assigned to a maintenance group and the others were assigned to the weaning group and steroids were tapered off over 4-6 weeks. Patients were monitored on subsequent office visits for adrenal insufficiency and allograft rejection. Results: Thirty-one patients were enrolled (6 patients in the maintenance group and 25 in the steroid-weaning group). Mean follow-up was 10.2 ± 4 years for the weaning group and 9.0 ± 4.9 years in the maintenance group (p = 0.6). No cases of rejection were noted, nor did any patient resume steroid treatment following discontinuation. Conclusion: Steroids can be safely discontinued in stable heart transplant patients with an AM serum cortisol ≥ 8 micrograms/deciliter with appropriate outpatient follow-up. In this study, no patient suffered late rejection or clinically noted adrenal insufficiency

    Mid-infrared quantum optics in silicon

    Full text link
    Applied quantum optics stands to revolutionise many aspects of information technology, provided performance can be maintained when scaled up. Silicon quantum photonics satisfies the scaling requirements of miniaturisation and manufacturability, but at 1.55 μ\mum it suffers from unacceptable linear and nonlinear loss. Here we show that, by translating silicon quantum photonics to the mid-infrared, a new quantum optics platform is created which can simultaneously maximise manufacturability and miniaturisation, while minimising loss. We demonstrate the necessary platform components: photon-pair generation, single-photon detection, and high-visibility quantum interference, all at wavelengths beyond 2 μ\mum. Across various regimes, we observe a maximum net coincidence rate of 448 ±\pm 12 Hz, a coincidence-to-accidental ratio of 25.7 ±\pm 1.1, and, a net two photon quantum interference visibility of 0.993 ±\pm 0.017. Mid-infrared silicon quantum photonics will bring new quantum applications within reach.Comment: 8 pages, 4 figures; revised figures, updated discussion in section 3, typos corrected, added referenc

    A cylindrical silicon-on-insulator microdosimeter: charge collection characteristics

    Get PDF
    A novel silicon-on-insulator microdosimeter for estimating the radiobiolgical effectiveness (RBE) of a mixed radiation field is presented. An ion beam induced charge collection study has confirmed the microdosimeter possesses well defined micron sized 3D cylindrical sensitive volumes. An array of these SVs has the capabilitiy of studying the track structure of high energy heavy ions typical of a deep space environment

    The biological effects of subacute inhalation of diesel exhaust following addition of cerium oxide nanoparticles in atherosclerosis-prone mice

    Get PDF
    AbstractBackgroundCerium oxide (CeO2) nanoparticles improve the burning efficiency of fuel, however, little is known about health impacts of altered emissions from the vehicles.MethodsAtherosclerosis-prone apolipoprotein E knockout (ApoE−/−) mice were exposed by inhalation to diluted exhaust (1.7mg/m3, 20, 60 or 180min, 5 day/week, for 4 weeks), from an engine using standard diesel fuel (DE) or the same diesel fuel containing 9ppm cerium oxide nanoparticles (DCeE). Changes in hematological indices, clinical chemistry, atherosclerotic burden, tissue levels of inflammatory cytokines and pathology of the major organs were assessed.ResultsAddition of CeO2 to fuel resulted in a reduction of the number (30%) and surface area (10%) of the particles in the exhaust, whereas the gaseous co-pollutants were increased (6–8%). There was, however, a trend towards an increased size and complexity of the atherosclerotic plaques following DE exposure, which was not evident in the DCeE group. There were no clear signs of altered hematological or pathological changes induced by either treatment. However, levels of proinflammatory cytokines were modulated in a brain region and liver following DCeE exposure.ConclusionsThese results imply that addition of CeO2 nanoparticles to fuel decreases the number of particles in exhaust and may reduce atherosclerotic burden associated with exposure to standard diesel fuel. From the extensive assessment of biological parameters performed, the only concerning effect of cerium addition was a slightly raised level of cytokines in a region of the central nervous system. Overall, the use of cerium as a fuel additive may be a potentially useful way to limit the health effects of vehicle exhaust. However, further testing is required to ensure that such an approach is not associated with a chronic inflammatory response which may eventually cause long-term health effects

    Managing Injuries of the Neck Trial (MINT) : design of a randomised controlled trial of treatments for whiplash associated disorders

    Get PDF
    Background: A substantial proportion of patients with whiplash injuries develop chronic symptoms. However, the best treatment of acute injuries to prevent long-term problems is uncertain. A stepped care treatment pathway has been proposed, in which patients are given advice and education at their initial visit to the emergency department (ED), followed by review at three weeks and physiotherapy for those with persisting symptoms. MINT is a two-stage randomised controlled trial to evaluate two components of such a pathway: 1. use of The Whiplash Book versus usual advice when patients first attend the emergency department; 2. referral to physiotherapy versus reinforcement of advice for patients with continuing symptoms at three weeks. Methods: Evaluation of the Whiplash Book versus usual advice uses a cluster randomised design in emergency departments of eight NHS Trusts. Eligible patients are identified by clinicians in participating emergency departments and are sent a study questionnaire within a week of their ED attendance. Three thousand participants will be included. Patients with persisting symptoms three weeks after their ED attendance are eligible to join an individually randomised study of physiotherapy versus reinforcement of the advice given in ED. Six hundred participants will be randomised. Follow-up is at 4, 8 and 12 months after their ED attendance. Primary outcome is the Neck Disability Index (NDI), and secondary outcomes include quality of life and time to return to work and normal activities. An economic evaluation is being carried out. Conclusion: This paper describes the protocol and operational aspects of a complex intervention trial based in NHS emergency and physiotherapy departments, evaluating two components of a stepped-care approach to the treatment of whiplash injuries. The trial uses two randomisations, with the first stage being cluster randomised and the second individually randomised

    3D silicon microdosimetry and RBE study using C-12 ion of different energies

    Get PDF
    This paper presents a new version of the 3D mesa "bridge" microdosimeter comprised of an array of 4248 silicon cells fabricated on 10 µm thick silicon-on-insulator substrate. This microdosimeter has been designed to overcome limitations existing in previous generation silicon microdosimeters and it provides well-defined sensitive volumes and high spatial resolution. The charge collection characteristics of the new 3D mesa microdosimeter were investigated using the ANSTO heavy ion microprobe, utilizing 5.5 MeV He2+ ions. Measurement of microdosimetric quantities allowed for the determination of the Relative Biological Effectiveness of 290 MeV/u and 350 MeV/u 12C heavy ion therapy beams at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. The microdosimetric RBE obtained showed good agreement with the tissue-equivalent proportional counter. Utilizing the high spatial resolution of the SOI microdosimeter, the LET spectra for 70 MeV 12C+6 ions, like those present at the distal edge of 290 and 350 MeV/u beams, were obtained as the ions passed through thin layers of polyethylene film. This microdosimeter can provide useful information about the lineal energy transfer (LET) spectra downstream of the protective layers used for shielding of electronic devices for single event upset prediction

    Thin Silicon Microdosimeter utilizing 3D MEMS Fabrication Technology: Charge Collection Study and its application in mixed radiation fields

    Get PDF
    New 10-μm-thick silicon microdosimeters utilizing 3-D technology have been developed and investigated in this paper. The TCAD simulations were carried out to understand the electrical properties of the microdosimeters\u27 design. A charge collection study of the devices was performed using 5.5-MeV He2+ ions which were raster scanned over the surface of the detectors and the charge collection median energy maps were obtained and the detection yield was also evaluated. The devices were tested in a 290 MeV/u carbon ion beam at the Heavy Ion Medical Accelerator in Chiba (HIMAC) in Japan. Based on the microdosimetric measurements, the quality factor and dose equivalent out of field were obtained in a mixed radiation field mimicking the radiation environment for spacecraft in deep space

    Measurement Analysis and Quantum Gravity

    Full text link
    We consider the question of whether consistency arguments based on measurement theory show that the gravitational field must be quantized. Motivated by the argument of Eppley and Hannah, we apply a DeWitt-type measurement analysis to a coupled system that consists of a gravitational wave interacting with a mass cube. We also review the arguments of Eppley and Hannah and of DeWitt, and investigate a second model in which a gravitational wave interacts with a quantized scalar field. We argue that one cannot conclude from the existing gedanken experiments that gravity has to be quantized. Despite the many physical arguments which speak in favor of a quantum theory of gravity, it appears that the justification for such a theory must be based on empirical tests and does not follow from logical arguments alone.Comment: 31 pages, many conceptual clarifications included, new appendix added, to appear in Phys. Rev.
    corecore